Datalogger review and alarm event history walkthrough.
Instrument Familiarization
Crowcon T4 Multigas Detector Simulator
Browser-based Crowcon T4 with live 4-gas display, menu navigation, alarm thresholds, and man-down / lone worker simulation.
Monitors LEL, O₂, CO, and H₂S with colour-coded alarm states.
Man-down tilt and panic alarm scenario walkthrough.
Device Training
GMI PS200 Gas Detector Simulator
Browser-based GMI PS200 portable four-gas detector simulator with live gas readings, alarm thresholds, bump test, and fresh-air calibration procedures.
Simulates LEL, O₂, CO, and H₂S channels on the PS200 display.
Warning and alarm thresholds with audible and visual alarm indication.
Biofuel blend operations for marine vessels — covering FAME/HVO blends, compatibility monitoring, filter management, and CII compliance.
Blend ratio controls, cold filter plugging point monitoring.
Fuel quality alerts and engine compatibility checks.
Systems Training
Wind-Assisted Propulsion Simulator
Flettner rotor and wing sail operations — IACS UR E27 and IMO MEPC.1/Circ.896 compliant, with live CII rating, Magnus effect physics, and fuel savings dashboard.
5 rotors with deploy/stow, RPM, and spin direction controls per rotor.
Live CII A–E badge, TWA wind rose, and fuel/CO₂ savings readout.
Systems Training
Battery / Hybrid Propulsion Simulator
6 MWh BESS diesel-electric hybrid on a PSV — DNV-ST-E407 and IEC 62619 compliant, covering shore power, battery thermal management, and zero-emission berthing.
Animated single-line electrical diagram with live power flow direction.
Thermal runaway precursor detection, cell voltage spread monitoring.
Fuel Training
LNG Fuel Gas Supply System Simulator — Hi-GAS
Hyundai Hi-GAS FGSS simulator for HMD2741 25K PC Tanker: 2×580 m³ Type C tanks, dual submerged LNG pumps (15.5 barg), shell & tube vaporiser with glycol water heating, X-DF main engine (6,410 kW), 3× HiMSEN generator engines, composition boiler, BOG heater, bunkering operations, N₂ inerting, and full ESDS per IGF Code.
Dual 580 m³ Type C LNG tanks (Port/Starboard) with 3-zone temperature monitoring, level, pressure, and BOG rate.
Dual submerged LNG pumps (duty/spare) with VFD speed control at 15.5 barg discharge.
AIS transponder trainer covering Class A/B operation, message types, target tracking, and SOLAS V/Reg.19.2.4 compliance. Includes voyage data input, rate-of-turn calculation, and AIS SART detection.
Class A transponder operation with dynamic and static data configuration
AIS target tracking with CPA/TCPA computation and collision risk assessment
VDR/S-VDR trainer covering data recording verification, capsule testing, annual performance testing (APT), and incident data preservation per SOLAS V/Reg.20 and IMO MSC.333(90).
Dynamic Positioning system trainer covering DP operations, position reference management, thruster allocation, and drift-off/drive-off scenarios per IMO MSC.1/Circ.1580 and IMCA M 103.
DP station-keeping with thruster allocation and power management
Multiple position reference system management (DGPS, HPR, taut wire)
Weather routing and voyage planning trainer covering passage plan preparation, weather analysis, route optimization, and SOLAS V/Reg.34 compliance. Includes BVS calculations and heavy weather avoidance.
Voyage planning with waypoint entry, ETD/ETA calculation, and fuel estimation
Weather overlay analysis: wind, wave, current, and tropical cyclone tracking
Compass trainer covering magnetic compass deviation/variation, gyro compass operation and errors, compass comparison procedures, and SOLAS V/Reg.19 compliance. Includes error calculation and correction.
Magnetic compass deviation card application and variation correction
Autopilot and track control system trainer covering heading control, track-keeping, weather adjustment, and changeover procedures per SOLAS V/Reg.19.2.8 and IMO MSC.64(67) Annex 3.
Heading hold, course change, and weather helm adjustment modes
Track control with cross-track error monitoring and waypoint sequencing
Echo sounder trainer covering depth measurement, transducer offset configuration, shallow water alarms, and bottom profiling per SOLAS V/Reg.19 and IEC 61162. Includes UKC monitoring and tide corrections.
Depth measurement with transducer draft offset and sound velocity correction
Programmable shallow and deep water alarms for under-keel clearance monitoring
Alfa Laval FOPX/LOPX centrifugal purifier simulator for fuel oil and lube oil separation per MEPC.1/Circ.642, covering bowl speed, desludging, and gravity disc selection.
Dual mode: FO Purifier (FOPX) and LO Purifier (LOPX) with mode-specific parameters.
Live gauges: bowl speed (RPM), feed temperature, throughput, back pressure, vibration.
15 ppm bilge separator with OCM and automatic 3-way divert valve per MARPOL Annex I Reg.14 and MEPC.107(49) — includes Oil Record Book entry simulation.
Oil Content Monitor (OCM) with real-time ppm display and automatic 15 ppm trip.
Three-way valve auto-divert to bilge holding tank when oil content exceeds 15 ppm.
Alfa Laval JWP-26-C100 plate-type evaporator simulator using engine JCW waste heat with vacuum evaporation, salinometer, and 12nm coastal restriction per SOLAS II-1.
Vacuum evaporation simulation with ejector pump, JCW heat source, and condenser.
Live gauges: JCW inlet/outlet temperature, vacuum (mbar), evaporation temperature, salinity, production rate.
Two-stage reciprocating air compressor and starting air system simulator per SOLAS II-1/Reg.26 — dual compressors, air bottles, cross-connection, and ME/AE start testing.
Dual compressor (No.1 and No.2) start/stop with inter-stage pressure and discharge temp gauges.
Air bottle 1 and 2 pressure gauges (0–30 bar) with live charging simulation.
Tanker ODME simulator per MARPOL Annex I Reg.31 and MEPC.108(49) — monitors instantaneous discharge rate (30 l/nm limit), position (50nm restriction), and logs to ORB Part II.
Real-time instantaneous discharge rate (l/nm) with automatic overboard valve trip at >30 l/nm.
Live position tracking with 50nm from land restriction and special area enforcement.
42,000 m³ fully refrigerated ammonia tanker — IGC Code Ch.19 and IMO MSC.1/Circ.1613. Full voyage from dry dock to discharge with PPE and IDLH monitoring.
4 prismatic tanks, reliquefaction, water curtain, and gas detection.
20-tank chemical tanker — IBC Code 2021, MARPOL Annex II. Multi-cargo operations with N₂ blanket, cargo heating, Butterworth tank cleaning, and IBC segregation compliance.
99,000 m³ VLEC with 4 bilobe tanks at −104°C — IGC Code Ch.19, STCW V/1-2, SIGTTO. Carries ethane and ethylene with full BOG management, reliquefaction, and cool-down operations.
Bilobe P&ID canvas, BOG rate vs reliq duty, sub-cooling margin, ethylene mode toggle.
Emergency: BOG excess, reliq overload, manifold gas leak, cargo overflow.
Systems Training
Grain Loading & Stability
Grain cargo loading simulator covering stability calculations, grain shifting moment, volumetric heeling moment, and compliance with the International Grain Code (SOLAS Ch.VI, IMO Grain Rules). Practice safe loading sequences and KG/GM verification.
Real-time stability calculation with KG, GM, and grain heeling moment monitoring.
Multi-hold loading sequence with trimming and ullage verification.
Container lashing and securing trainer covering stack weight calculations, lashing rod tensioning, twist-lock verification, and CSS Code compliance. Includes parametric rolling scenarios and container collapse prevention.
Lashing rod tension calculation and verification per CSS Code Annex 14
Stack weight and tier distribution monitoring with wind force analysis
Reefer container monitoring trainer covering temperature control, power supply management, controlled atmosphere settings, and cargo care per IMDG Code and ATP Agreement. Includes alarm response for temperature deviations.
Temperature monitoring and alarm management for up to 500+ reefer units
Power supply monitoring: 440V/60Hz and 220V/50Hz socket management
High-pressure CO2 total flooding system simulator for engine room and cargo pump room. Covers full discharge sequence, boundary damper control, and evacuation procedures per SOLAS II-2/Reg.10, FSS Code Ch.5, and IACS UR F15.
72-cylinder CO2 bank with reserve tracking and pressure monitoring.
Ship-wide ESD panel for tankers and gas carriers. Three-level shutdown logic covering cargo manifold, pump ESD valves, engine room isolation, and HVAC shutdown per SOLAS II-2, IGC Code Ch.18, and IEC 61508 SIL 2.
Three ESD levels: cargo ops stop, emergency stop with full valve closure, full ship emergency.
8 cargo manifold valves (4 port, 4 starboard) with real-time position feedback and closure animation.
Addressable fire detection and alarm system with 12 zones covering all ship spaces. Includes optical smoke, heat (ROR/fixed), and flame detectors with automatic fire-fighting actions per SOLAS II-2/Reg.7, FSS Code Ch.9, and IMO MSC.1/Circ.1477.
Fixed multi-gas detection system for gas carriers and tankers. Monitors HC (%LEL), H2S, O2, CO, and NH3 across 6 zones with alarm setpoints, automatic ESD/ventilation actions, and sensor fault diagnostics per IGC Code Ch.13, SOLAS II-2, and IEC 60092-504.
IMO BWM Convention D-2 compliant UV irradiation BWTS — auto-backflush filter, UV dose monitoring, lamp health tracking, and ballast/deballast operations.
UV reactor with 4 lamp health bars and intensity readout in mJ/cm².
D-2 biological compliance table with live organism count simulation.
Regulatory Compliance
Electrochlorination BWTS Simulator
Electrochlorination BWTS — G9 type approved. EC cell current/voltage control, TRO monitoring at cell and discharge, electrode fouling simulation, and Na₂S₂O₃ neutralisation.
3 electrode pairs with individual health bars and salinity factor correction.
TRO at cell outlet, holding tank, and discharge point — USCG 0.2 mg/L limit.
Regulatory Compliance
Ozone Treatment BWTS Simulator
Ozone treatment BWTS — G9 type approved. Corona discharge generator, air dryer, CT value monitoring, and mandatory off-gas destructor interlock.
Feed gas selector (AIR/O₂), CT target ≥3 mg·min/L with live contact time.
O₃ in air safety monitor with TWA/STEL alarm and evacuation banner.
Regulatory Compliance
Chemical Dosing BWTS Simulator
Chemical dosing BWTS — G9 type approved. Selectable active substance (NaOCl, H₂O₂, ClO₂, Glutaraldehyde), metering pump control, and IBC tank level display.
4 selectable chemicals with individual dose targets and contact time requirements.
G9 approval data sheet display and contact time accumulator vs minimum required.
Regulatory Compliance
UV+EC Hybrid BWTS Simulator
UV+EC dual-barrier BWTS — G8+G9 type approved. Mode selector (UV ONLY / HYBRID / EC ONLY), combined efficacy calculation, and individual barrier monitoring.
Main Switchboard (MSB) and Emergency Switchboard (ESB) operation training with clickable breakers, bus tie control, earth fault indicators, and tripped breaker reset.
Full MSB single-line diagram with clickable OPEN/CLOSED/TRIPPED breakers.
Emergency Switchboard with essential load feeders and auto bus transfer relay.
IT system earth fault detection and isolation training with flashing earth fault lamp, section-by-section isolation procedure, and resistance measurement display.
IT insulated system with flashing earth fault lamp and resistance indicator.
20+ feeder circuits for systematic section-by-section isolation.
High Voltage Shore Connection (HVSC) cold ironing simulator with voltage/frequency matching, frequency converter, transformer tap changer, and CO2 savings display.
6.6kV/11kV shore supply with transformer and frequency converter.
Full connection procedure: phase check, voltage match, breaker close, DG unload.
Electro-hydraulic steering gear trainer with bridge and emergency local control, dual pump units, FU/NFU modes, and emergency steering changeover drill.
Dual pump units (P1/P2) with auto-start on failure.
FU (Follow-Up) and NFU (Non-Follow-Up) control modes.
Battery Energy Storage System (BESS) integrated with diesel-electric propulsion. Hybrid, zero-emission, and peak shaving modes with live energy flow diagram.
2,000 kWh BESS with SoC, cell voltage, temperature, and health monitoring.
Four operating modes: Diesel Only, Hybrid, Battery Only, Charging.
Enclosed space entry procedure simulator covering atmosphere testing, ventilation, permit issuance, and rescue planning per SOLAS Reg.XI-1/7, MSC.1/Circ.1401, Resolution A.1050(27), and COSWP Chapter 10. Practice the complete entry protocol.
Multi-gas atmosphere testing with O2, LEL, H2S, and CO readings.
Step-by-step permit-to-enter workflow with responsible officer sign-off.
Permit to Work (PTW) system simulator covering hot work, cold work, electrical isolation, and confined space entry permits per ISM Code, ISGOTT Ch.11, COSWP, and company SMS procedures. Practice permit issuance, risk controls, and closeout.
Risk assessment simulator covering hazard identification, risk matrix evaluation, control measure selection, and residual risk calculation per ISM Code Section 7, ISO 31000, COSWP, and TMSA Element 4. Practice systematic risk management.
Interactive 5x5 risk matrix with likelihood and severity scoring.
Hazard identification library with maritime-specific scenarios.
Shipboard Oil Pollution Emergency Plan (SOPEP) response simulator. Practice oil spill containment, notification procedures, dispersant use, and equipment deployment per MARPOL Annex I Reg.37, MEPC.1/Circ.778, and OPRC Convention.
Spill source identification and containment boom deployment around deck areas.
SOPEP notification chain: Master, Company, Port State, Flag State authorities.
EPIRB and SART activation simulator covering manual deployment, auto-float hydrostatic release, self-test procedures, and signal verification per SOLAS Ch.IV, Ch.III Reg.6.2, ITU Radio Regulations, and IMO Resolution A.810(19). Practice distress alerting.
EPIRB manual activation sequence with 406 MHz signal and GPS position encoding.
SART transponder activation with 9 GHz radar response signal verification.
Interactive anchor windlass trainer covering anchor deployment, heaving, and emergency release per SOLAS II-1/Reg.3.4 and IACS UR A1. Includes chain counter monitoring, brake management, and windlass motor protection.
Anchor deployment and recovery with chain counter and brake control
Emergency anchor release (SOLAS II-1 compliant) and windlass clutch management
SOLAS-compliant inflatable life raft deployment trainer covering manual and hydrostatic release, painter line operation, and boarding procedures per SOLAS III/Reg.13 and LSA Code Ch.VI.
Manual deployment: cradle release, launching, and painter line activation
Hydrostatic Release Unit (HRU) automatic deployment simulation
Pilot ladder and accommodation ladder rigging trainer per SOLAS V/Reg.23 and IMO Res.A.1045(27). Covers ladder inspection, rigging height calculations, combination arrangements, and safety zone management.
Pilot ladder rigging with correct freeboard height calculations per SOLAS V/Reg.23
Combination arrangement (accommodation + pilot ladder) for freeboard > 9m
Hose handling trainer for bunkering and ship-to-ship (STS) transfer operations per OCIMF guidelines, MARPOL Annex I, and ISGOTT. Covers hose connection, pressure testing, flow monitoring, and emergency disconnection.
Hose connection and disconnection procedures per OCIMF Ship-to-Ship Transfer Guide
Bunkering operation with flow rate control, tank monitoring, and spill prevention
Two-stroke slow-speed main propulsion engine simulator based on a MAN B&W 6S60ME-C. Covers normal start-up, sea-speed operation, HFO/MDO fuel changeover, and LO low-pressure emergency procedures. STCW II/1, III/1, SOLAS II-1/26.
Normal start-up procedure: pre-lubrication, starting air charge, fuel selection, slow turn, and engagement.
Sea-speed full-away with fuel index management, turbocharger, and temperature monitoring.
Engine order telegraph simulator covering bridge-to-engine room order transmission, speed and direction commands, acknowledgement protocol, and Finished With Engines signalling.
Full telegraph dial with nine positions: Full/Half/Slow/Dead Slow Ahead and Astern, plus Stop.
Bridge order and engine room acknowledgement dual-needle display.
Stern tube and shaft seal system simulator covering oil-lubricated and seawater-lubricated stern tube bearings, aft and forward seals, header tank management, and leak detection per Classification Society rules and MARPOL Annex I.
Aft and forward seal oil pressure monitoring with header tank level control.
Bearing temperature monitoring with high-temperature alarm logic.
Jacket cooling water (JCW) system simulator covering HT/LT circuits, thermostatic valve control, expansion tank management, and freshwater generator heat recovery per main engine manufacturer guidelines and Classification Society requirements.
HT and LT cooling circuit operation with thermostatic valve control.
Expansion tank level and pressure monitoring with auto-makeup.
Main engine lubricating oil system simulator covering sump tank circulation, LO cooler, auto-filter, purifier feed, and crosshead lubrication per engine manufacturer specifications and Classification Society requirements.
LO pump operation with pressure regulation and standby pump auto-start.
Auto-backflush filter monitoring with differential pressure trending.
Fuel oil treatment system simulator covering settling tank heating, purifier operation, service tank transfer, and fuel quality monitoring per MARPOL Annex VI, ISO 8217, and engine manufacturer fuel specifications.
Settling and service tank heating control with viscosity-temperature curves.
Purifier throughput and separation efficiency monitoring with sludge discharge.
Starting air system simulator covering air compressor operation, air receiver charging, main engine starting sequence, and control air supply per SOLAS Ch.II-1 Reg.26, Classification Society rules, and engine manufacturer procedures.
Air receiver pressure monitoring with auto-start compressor logic at 25 bar.
Main engine starting air distributor valve sequencing and turning gear interlock.
Exhaust gas boiler (economizer) simulator covering waste heat recovery, steam drum level control, soot blowing, and uptake fire prevention per SOLAS Ch.II-2, Classification Society rules, and CIMAC recommendations for exhaust gas boiler operation.
Steam drum level control with feedwater regulation and low-level alarm.
Soot blowing sequence with exhaust gas temperature differential monitoring.
Turbocharger surge simulator covering compressor map operation, surge line proximity, auxiliary blower cut-in, and scavenge air pressure management per engine manufacturer guidelines and Classification Society requirements for turbocharger protection.
Compressor map visualization with operating point and surge line proximity.
Auxiliary blower auto-start logic at low scavenge air pressure threshold.
Solar photovoltaic system monitoring simulator covering array performance, MPPT tracking, inverter operation, and grid-tie per IEC 61724 and IEEE 1547.
Interactive P&ID schematic with real-time process visualization and flow animation.
Realistic physics engine modeling solar pv system monitoring parameters with configurable scenarios.
Nuclear reactor basics simulator covering BWR and PWR configurations, control rod operation, neutron flux monitoring, and reactor protection per 10 CFR 50 and IAEA NS-R-1.
Interactive P&ID schematic with real-time process visualization and flow animation.
HV transformer and switchgear simulator covering protection relays, tap-changer operation, oil temperature monitoring, and circuit-breaker sequencing per IEC 60076 and IEEE C57.
Interactive P&ID schematic with real-time process visualization and flow animation.
Battery energy storage system simulator covering Li-ion cell monitoring, BMS operation, charge/discharge cycles, and thermal management per IEC 62619 and UL 9540.
Interactive P&ID schematic with real-time process visualization and flow animation.
Realistic physics engine modeling battery energy storage system (bess) parameters with configurable scenarios.
Grid synchronization simulator covering synchroscope operation, voltage matching, frequency matching, and phase-angle alignment per IEEE 1547 and IEC 60034.
Interactive P&ID schematic with real-time process visualization and flow animation.
Realistic physics engine modeling grid synchronization parameters with configurable scenarios.
Power distribution and load shedding simulator covering bus configurations, automatic load-shed logic, and priority-based restoration per IEEE 446 and IEC 61850.
Interactive P&ID schematic with real-time process visualization and flow animation.
Realistic physics engine modeling power distribution & load shedding parameters with configurable scenarios.
Cooling tower system simulator covering fan operation, basin temperature control, chemical treatment, and approach/range calculations per CTI ATC-105 and ASHRAE.
Interactive P&ID schematic with real-time process visualization and flow animation.
Realistic physics engine modeling cooling tower system parameters with configurable scenarios.
Distillation column simulator covering tray hydraulics, reboiler/condenser control, reflux ratio, and product purity per ASME Section VIII and API 526.
Interactive P&ID schematic with real-time process visualization and flow animation.
Shell-and-tube heat exchanger simulator covering thermal duty, fouling factor, approach temperature, and flow management per TEMA standards and ASME Section VIII.
Interactive P&ID schematic with real-time process visualization and flow animation.
Chemical reactor simulator covering CSTR and batch modes with temperature control, conversion tracking, and runaway prevention per API 520 and DIERS guidelines.
Interactive P&ID schematic with real-time process visualization and flow animation.
Realistic physics engine modeling reactor (cstr / batch) control parameters with configurable scenarios.
Multi-effect evaporator and crystallizer simulator covering heat balance, vacuum control, crystal growth, and steam economy per API 560 and industrial practice.
Interactive P&ID schematic with real-time process visualization and flow animation.
Control valve simulator covering valve characteristics (linear, equal-percentage), cavitation, positioner calibration, and flow coefficient per ISA-75.01 and IEC 60534.
Interactive P&ID schematic with real-time process visualization and flow animation.
Realistic physics engine modeling control valve operation parameters with configurable scenarios.
Pressure safety valve and relief valve simulator covering set-pressure testing, blowdown adjustment, and certification per ASME Section VIII, API 520, and API 527.
Interactive P&ID schematic with real-time process visualization and flow animation.
Flammable atmosphere and LEL monitoring simulator covering catalytic/IR detector operation, alarm response, and confined space entry per IEC 60079 and NFPA 497.
Interactive P&ID schematic with real-time process visualization and flow animation.
Chemical dosing system simulator covering metering pump control, concentration monitoring, pH/ORP control, and chemical inventory per API 675 and ISA-5.1.
Interactive P&ID schematic with real-time process visualization and flow animation.
Realistic physics engine modeling chemical dosing system parameters with configurable scenarios.
Central air conditioning plant simulator covering chilled water generation, AHU distribution, compressor staging, and condenser water loop control per ASHRAE 90.1 and AHRI standards.
Chiller start/stop sequencing with compressor staging and load management.
Chilled water supply/return temperature control with 3-way valve modulation.
Centrifugal and screw chiller simulator covering compressor operation, oil system management, refrigerant circuit control, and capacity modulation per ASHRAE 15 and AHRI 550/590.
Compressor start sequence with oil pressure differential verification and guide vane control.
Evaporator and condenser heat exchanger monitoring with approach temperature analysis.
Vapor-compression refrigeration cycle simulator with selectable refrigerants (R134a, R410A, CO2 transcritical) covering P-h diagrams, COP calculation, and superheat/subcooling control per ASHRAE 34 and EN 378.
Interactive P-h (pressure-enthalpy) diagram with real-time operating point tracking.
Selectable refrigerants: R134a, R410A, and CO2 transcritical cycle.
Cold room and cold storage system simulator covering temperature pull-down, defrost cycles, door management, and product temperature monitoring per HACCP and FDA 21 CFR 110 guidelines.
Temperature pull-down from ambient to setpoint with compressor capacity staging.
Defrost cycle management: electric, hot gas, and off-cycle defrost methods.
Air handling unit simulator covering mixed air control, heating/cooling coils, humidification, filter monitoring, and economizer operation per ASHRAE 62.1 and ASHRAE 90.1.
Mixed air damper control with outdoor air economizer and enthalpy-based switchover.
Heating and cooling coil valve modulation with discharge air temperature control.
Cooling water system simulator covering cooling tower operation, condenser water pump sequencing, chemical treatment, and approach temperature optimization per CTI STD-201 and ASHRAE guidelines.
Cooling tower fan staging with wet-bulb approach temperature control.
Condenser water pump sequencing with variable flow and bypass valve control.
Duct design and airflow simulator covering friction loss calculation, equal friction method, static regain, and duct sizing per ASHRAE Fundamentals and SMACNA standards.
Interactive duct network layout with main trunk and branch sizing.
Friction loss calculation using Darcy-Weisbach and Colebrook equations.
Aircraft hydraulic system simulator covering engine-driven and electric pump operation, accumulator pre-charge, system isolation, and redundancy management per ATA 29 and FAR 25.1435.
Multi-system hydraulic architecture (Green/Blue/Yellow) with engine-driven and electric pumps.
Accumulator pre-charge and pressure monitoring with nitrogen servicing.
Aircraft pneumatic and bleed air system simulator covering engine bleed extraction, pack valve control, precooler regulation, and cross-bleed operation per ATA 36 and FAR 25.831.
Engine bleed air extraction with HP/LP valve selection and pressure regulation.
Precooler temperature control with fan air modulation and overheat protection.
Auxiliary Power Unit start/stop simulator covering start sequence, EGT monitoring, bleed air/electrical load management, and shutdown procedures per ATA 49 and OEM limitations.
Landing gear system simulator covering extension/retraction sequencing, weight-on-wheels logic, brake system, and nose wheel steering per ATA 32 and FAR 25.729.
Landing gear extension/retraction with hydraulic sequencing and door logic.
Weight-on-wheels (WOW) sensor logic and ground/flight mode transitions.
Aircraft fuel system simulator covering wing tank management, center tank transfer, cross-feed operation, fuel jettison, and CG management per ATA 28 and FAR 25.963.
Multi-tank fuel architecture with wing, center, and trim tank management.
Boost pump operation, cross-feed valve control, and engine feed logic.
Aircraft fire detection and suppression simulator covering engine fire loops, cargo fire bottles, APU fire protection, and fire drill procedures per ATA 26 and FAR 25.851/25.869.
Dual-loop fire detection with A/B loop logic and fault isolation.
Engine fire bottle discharge sequencing with agent concentration monitoring.
Aircraft pressurization system simulator covering cabin altitude control, outflow valve modulation, safety valve operation, and rapid decompression response per ATA 21 and FAR 25.841.
Cabin altitude and differential pressure control with outflow valve modulation.
Automatic pressurization schedule based on cruise altitude and landing field elevation.
Turbofan engine start sequence simulator covering ground start, cross-bleed start, N1/N2 spool-up, EGT monitoring, and start malfunction recognition per ATA 72 and FAR 33.73.
Aircraft electrical bus and generator simulator covering AC/DC bus architecture, generator control, bus tie logic, and emergency power management per ATA 24 and FAR 25.1351.
AC and DC bus architecture with main, essential, and emergency bus segments.
Integrated Drive Generator (IDG) and generator control unit (GCU) operation.
Electric vehicle battery management system simulator covering cell balancing, SoC/SoH estimation, thermal management, and fault protection per SAE J2464 and IEC 62660.
Cell-level voltage and temperature monitoring with passive/active balancing.
State of Charge (SoC) and State of Health (SoH) estimation algorithms.
Electric vehicle charging station simulator covering Level 1/2 AC and DC fast charging protocols, EVSE communication, and charge curve management per SAE J1772, CCS, and CHAdeMO standards.
Level 1 (120V), Level 2 (240V), and DC Fast Charge (50-350 kW) modes.
EVSE pilot signal communication and vehicle handshake protocol.
Hybrid powertrain simulator covering parallel, series, and power-split architectures with energy flow visualization, regenerative braking, and mode transitions per SAE J2841.
Selectable hybrid architectures: parallel, series, and power-split (planetary gear).
Real-time energy flow diagram showing ICE, motor/generator, and battery paths.
Anti-lock braking system and traction control simulator covering wheel speed sensing, hydraulic modulator operation, slip ratio control, and stability management per FMVSS 135 and ECE R13H.
Four-channel ABS with individual wheel speed sensors and slip ratio calculation.
Hydraulic modulator with pressure hold, pressure decrease, and pressure increase cycles.
Automotive engine cooling system simulator covering thermostat operation, water pump flow, radiator heat rejection, and electric fan control per SAE J1004 and SAE J816.
Thermostat wax-element operation with progressive opening and bypass control.
Water pump flow rate calculation based on engine RPM and impeller characteristics.
OBD-II diagnostic simulator covering DTC reading, freeze frame data, live PID monitoring, readiness monitor status, and Mode 01-09 operations per SAE J1979 and ISO 15031.
DTC (Diagnostic Trouble Code) reading with P0xxx code interpretation.
Transmission simulator covering manual gearbox synchromesh operation, automatic planetary gear sets with torque converter, and CVT belt/pulley ratio control per SAE J306 and SAE J311.
Manual transmission with synchromesh engagement, clutch operation, and gear ratio visualization.
Automatic transmission with planetary gear sets, torque converter lockup, and shift schedule.
Interactive conveyor belt system simulator covering belt speed control, load monitoring, emergency stops, and alignment tracking for mining and bulk material handling operations.
Belt speed control with variable frequency drive (VFD) and load-dependent auto-adjustment.
Emergency stop pull-cord simulation with zone isolation and restart interlocks.
Crusher and grinding mill simulator covering jaw/cone crusher operations, feed rate control, discharge size adjustment, and lubrication system monitoring for mineral processing.
Crusher feed rate control with choke-feed detection and CSS (closed-side setting) adjustment.
Lubrication oil pressure, bearing temperature, and motor current monitoring.
Underground mine ventilation simulator covering main fan operation, auxiliary ventilation, airflow distribution, gas monitoring, and emergency ventilation procedures.
Main surface fan operation with VFD speed control and damper position management.
Real-time airflow distribution across multiple headings with pressure differential monitoring.
Dust suppression system simulator covering water spray, fog cannon, and chemical surfactant dosing for mining haul roads, crushers, transfer points, and stockpiles.
Multi-zone spray control with nozzle pressure monitoring and water consumption tracking.
Fog cannon directional control with wind compensation and particle size optimization.
Underground mining gas detection simulator covering continuous monitoring of CH4, CO, O2, NO2, and H2S with alarm management, evacuation procedures, and ventilation response.
Multi-gas sensor array monitoring CH4 (0-5% LEL), CO, O2 depletion, and toxic gas levels.
Alarm escalation from caution to evacuation with zone-based response protocols.
Water treatment plant simulator covering coagulation, flocculation, sedimentation, filtration, and disinfection processes for potable water production.
Coagulant and flocculant dosing with jar test optimization and turbidity monitoring.
Sedimentation basin sludge blanket level control and filter backwash sequencing.
Reverse osmosis plant simulator covering membrane feed pressure control, permeate quality monitoring, CIP procedures, and energy recovery for desalination and water purification.
High-pressure pump control with membrane feed pressure, flux rate, and recovery ratio management.
Permeate conductivity, salt rejection rate, and differential pressure monitoring.
Chlorination and disinfection simulator covering gas chlorination, sodium hypochlorite dosing, contact time management, and residual monitoring for water and wastewater treatment.
Chlorine gas feed rate control with vacuum regulator, injector, and residual analyzer feedback.
CT (concentration x time) calculation with contact chamber baffling factor and flow pacing.
Pump station SCADA simulator covering multi-pump sequencing, wet well level control, VFD speed management, and telemetry for water and wastewater pumping stations.
Multi-pump start/stop sequencing with wet well level setpoints and duty rotation.
VFD speed control with constant pressure/level PID loop and energy optimization.
Water distribution network simulator covering pressure zone management, PRV operation, tank level balancing, and leak detection for municipal water supply systems.
Pressure zone management with PRV setpoint control and zone isolation valve operation.
Storage tank level balancing with fill/drain cycle optimization and overflow prevention.
Anaesthesia machine simulator covering fresh gas flow, vaporizer control, circle breathing system, ventilator modes, and safety systems for anaesthesia delivery training.
Fresh gas flow control with O2/N2O/Air mixing, hypoxic guard, and minimum O2 ratio enforcement.
Vaporizer dial control with agent-specific MAC calculations and temperature compensation.
Medical gas pipeline system (MGPS) simulator covering O2, N2O, compressed air, and vacuum supply with manifold changeover, alarm management, and zone valve operation.
Manifold automatic changeover with primary/reserve bank status and cylinder pressure monitoring.
Pipeline pressure regulation, area alarm panel monitoring, and zone valve shut-off operation.
Automated external defibrillator trainer simulator covering pad placement, rhythm analysis, shock delivery, CPR timing, and AED protocol for basic life support training.
Step-by-step AED protocol with voice prompt simulation and visual pad placement guidance.
Addressable fire alarm control panel simulator covering zone mapping, detector programming, loop wiring verification, and cause-and-effect matrix configuration per NFPA 72 and BS 5839.
Addressable loop configuration with detector, MCP, and sounder base device mapping across multiple zones.
Cause-and-effect matrix programming for automatic suppression release, door holder release, and HVAC shutdown.
Wet and dry sprinkler system simulator covering jockey pump operation, main fire pump start, flow switch activation, and zone valve control per NFPA 13 and BS EN 12845.
Jockey pump auto-start on header pressure drop with main fire pump cascade activation sequence.
Sprinkler head activation simulation with flow rate calculation and zone identification.
Aqueous Film Forming Foam (AFFF) suppression system simulator covering proportioning, foam concentrate storage, bladder tank operation, and discharge testing per NFPA 11 and NFPA 16.
Balanced-pressure proportioning system with 3% and 6% concentrate ratio selection and inline inductor.
Bladder tank level monitoring, foam concentrate quality check, and expansion ratio verification.
Fire hydrant and hose reel operation simulator covering hydrant valve operation, hose deployment, nozzle pattern selection, and pressure/flow management per NFPA 14 and BS EN 671.
Hydrant valve operation with residual and static pressure monitoring at multiple hydrant locations.
Hose reel deployment sequence with nozzle pattern selection (jet, spray, fog) and flow rate control.
Smoke management and extraction system simulator covering smoke detector integration, extraction fan control, damper positioning, and pressurization strategy per NFPA 92 and BS EN 12101.
Multi-zone smoke detection with automatic extraction fan start and damper open sequence.
Stairwell pressurization and lobby ventilation control for safe evacuation route maintenance.
Clean agent gas suppression system simulator covering FM200 and Novec 1230 systems with cylinder bank management, detection sequence, pre-discharge timer, and room integrity per NFPA 2001 and ISO 14520.
Dual-zone detection (smoke + heat) with cross-zone verification and pre-discharge countdown timer.
Cylinder bank pressure monitoring, solenoid valve release, and agent concentration calculation.
Fire pump house simulator covering electric and diesel-driven fire pumps, jockey pump, pressure switches, automatic transfer, and weekly test run per NFPA 20 and BS EN 12845.
Electric and diesel fire pump auto-start sequence with jockey pump pressure maintenance logic.
Controller panel with pressure switch settings, timer configuration, and automatic transfer switching.
Building Management System simulator covering HVAC scheduling, lighting control, energy metering, trend logging, and alarm management per ASHRAE standards and BACnet protocol.
HVAC scheduling with setpoint management, AHU start/stop sequencing, and occupancy-based control.
Energy dashboard with real-time power, water, and gas metering and trend logging display.
Elevator and lift control system simulator covering traction drive operation, door zone logic, safety circuit chain, firefighter mode, and rescue operation per EN 81 and ASME A17.1.
Multi-floor call allocation with group supervisory control and destination dispatch logic.
Safety circuit chain monitoring including door locks, governor, buffer, and overspeed detection.
UPS and backup power system simulator covering online double-conversion UPS operation, battery management, bypass switching, and load transfer per IEC 62040 and NFPA 111.
Online double-conversion UPS with rectifier, inverter, and static bypass switch operation.
Battery charge/discharge cycle monitoring with autonomy calculation and end-of-discharge protection.
Integrated access control and CCTV surveillance system simulator covering card reader programming, door controller configuration, camera PTZ control, and event correlation per CPNI and SIA standards.
Access control door programming with card reader enrollment, time zone schedules, and anti-passback logic.
CCTV camera configuration with PTZ presets, motion detection zones, and recording schedule setup.
Diesel generator set and Automatic Mains Failure panel simulator covering DG start sequence, load pickup, synchronization, and AMF changeover logic per ISO 8528 and BS 7671.
DG pre-start checks, cranking sequence, engine warm-up, and AMF automatic changeover on mains failure.
Load management with sequential load pickup, load shedding priority, and reverse power protection.
Solar PV system with inverter and grid-tie simulator covering MPPT tracking, DC-AC conversion, anti-islanding protection, and net metering per IEC 62109 and IEEE 1547.
Solar array I-V curve visualization with MPPT algorithm tracking and partial shading response.
Grid-tie inverter operation with power factor control, anti-islanding detection, and reconnection timer.
Integrated fire alarm and public address system simulator covering voice evacuation, zone paging, pre-recorded message playback, and all-call operation per NFPA 72 and BS 5839-8.
Voice evacuation with pre-recorded Alert and Evacuate messages and zone-selective paging control.
Fire alarm integration with automatic PA activation on zone alarm and manual override microphone.
Managed network switch and router simulator covering VLAN configuration, port security, spanning tree protocol, and basic routing per IEEE 802.1Q and RFC standards.
VLAN creation and port assignment with trunk/access mode configuration and inter-VLAN routing.
Spanning Tree Protocol visualization with root bridge election, port states, and convergence timing.
Fiber optic splicing and testing trainer covering fusion splicing procedure, OTDR trace analysis, connector polishing, and loss budget calculation per ITU-T G.652 and TIA-568.
Fusion splicing step-by-step procedure with fiber preparation, alignment, arc fusion, and splice loss estimation.
OTDR trace reading with event identification (connectors, splices, bends, breaks) and distance measurement.
Server rack power distribution and cooling management simulator covering PDU configuration, hot/cold aisle containment, environmental monitoring, and capacity planning per ASHRAE TC 9.9 and TIA-942.
Dual PDU power distribution with per-outlet monitoring, load balancing, and redundancy verification.
Rack inlet temperature monitoring with hot/cold aisle containment effectiveness and airflow management.
IP camera and CCTV system setup simulator covering network configuration, PoE power management, video stream settings, NVR storage calculation, and ONVIF integration per ONVIF Profile S/T.
IP camera network setup with PoE allocation, VLAN segregation, and multicast stream configuration.
Video stream configuration with resolution, frame rate, codec selection, and bandwidth calculation.
Data center cooling system simulator covering precision air conditioning, chilled water systems, hot/cold aisle containment, and free cooling economizer operation per ASHRAE TC 9.9 and Uptime Institute.
CRAC/CRAH unit operation with supply/return temperature control, humidity management, and airflow distribution.
Chilled water plant with chiller staging, pump sequencing, and condenser water temperature optimization.
Irrigation pump and valve control simulator covering centrifugal pump operation, drip/sprinkler valve scheduling, soil moisture feedback, and VFD-based flow control per ISO 9635 and ASABE standards.
Centrifugal pump start/stop with priming, VFD speed control, and discharge pressure monitoring.
Zone-based valve scheduling with drip and sprinkler mode selection and soil moisture feedback loop.
Cold chain temperature monitoring simulator covering refrigerated storage, transport tracking, HACCP compliance logging, and excursion alarm management per Codex Alimentarius and WHO PQS.
Multi-zone temperature monitoring with configurable setpoints for chilled (2-8C) and frozen (-18C) storage.
HACCP-compliant data logging with time-temperature recording, excursion flagging, and audit trail.
Pasteurization plant simulator covering HTST and batch pasteurization, flow diversion valve control, holding tube residence time, and CIP cleaning per PMO and Codex CAC/RCP 57.
HTST pasteurization with plate heat exchanger, holding tube, and flow diversion valve (FDV) control.
Temperature recording with legal hold point verification, divert on undertemp, and chart recorder output.
Greenhouse climate control simulator covering temperature, humidity, CO2 enrichment, automated venting, shade screen control, and irrigation scheduling per ASABE EP406 and NGMA standards.
Temperature control with heating (boiler/unit heater) and cooling (evaporative pad, fan ventilation) staging.
Humidity management with dehumidification, fogging system, and VPD (vapor pressure deficit) calculation.