COMPRESSORS
COMPRESSOR No.1
STATUS: STOPPED
COMPRESSOR No.2
STATUS: STOPPED

BOTTLE PRESSURE
Air Bottle 10.0bar
Air Bottle 20.0bar

ME/AE START TEST
P&ID SCHEMATIC — STARTING AIR SYSTEM
COMPRESSOR No.1 STG 1 6-8b STG 2 30b 0.0 bar M COMPRESSOR No.2 STG 1 6-8b STG 2 30b 0.0 bar M NRV NRV AIR BOTTLE 1 0.0 bar SV 32b AIR BOTTLE 2 0.0 bar SV 32b X-CONN [CLOSED] MAIN LINE MAIN ENGINE START ME-V AUX ENGINE START DIESEL GEN START PRV → 7 bar DISC TEMP C1 --°C DISC TEMP C2 --°C SCENARIO: -- Select scenario to begin
ALARM MANAGEMENT
ACTIVE ALARMS
VALVE LINEUP
BOTTLE INLETS
STARTING AIR SUPPLY
CROSS-CONNECTION

DRAIN VALVES
BOTTLE PRESSURE TREND
SYSTEM STATUS
START CAPABILITY
ME Starts avail: --
AE Starts avail: --

SOLAS COMPLIANCE

COMPRESSOR P&ID — TWO-STAGE RECIPROCATING
COMPRESSOR CONTROLS
COMPRESSOR No.1
Stage 1 Pressure-- bar
Stage 2 Pressure-- bar
Discharge Temp-- °C
Running Hours-- h
COMPRESSOR No.2
Stage 1 Pressure-- bar
Stage 2 Pressure-- bar
Discharge Temp-- °C
Running Hours-- h
UNLOADING VALVES
Unloader C1
Unloader C2
AIR RECEIVERS — BOTTLE DETAIL & CONNECTIONS
RECEIVER CONTROLS
AIR BOTTLE 1
Pressure-- bar
Temperature-- °C
Capacity250 L
Inlet Valve
Drain Valve
Safety Valve Set32 bar
AIR BOTTLE 2
Pressure-- bar
Temperature-- °C
Capacity250 L
Inlet Valve
Drain Valve
Safety Valve Set32 bar
CROSS-CONNECTION
X-Conn Valve
StatusISOLATED
NRV STATUS
STARTING AIR DISTRIBUTION — ME / AE / CONTROL AIR
DISTRIBUTION CONTROLS
MAIN ENGINE START
Supply Valve
Line Pressure-- bar
Starts Available--
AUX ENGINE START
Supply Valve
Line Pressure-- bar
Starts Available--
CONTROL AIR
PRV Set Point7 bar
Control Air Press-- bar
PRV StatusNORMAL
SOLAS II-1/REG.26
COOLING WATER SYSTEM — INTERCOOLER & AFTERCOOLER
COOLING CONTROLS
COOLING WATER TEMPERATURES
CW Supply Temp-- °C
CW Return Temp-- °C
Intercooler Outlet-- °C
Aftercooler Outlet-- °C
COOLING WATER FLOW
CW Inlet Valve
CW Outlet Valve
CW Flow Rate-- L/min
LUBRICATING OIL
LO Pressure C1-- bar
LO Pressure C2-- bar
LO Temperature-- °C
Oil Level C1NORMAL
HIGH-TEMP TRIPS
HH Disc Temp Trip175 °C
H CW Temp Alarm55 °C
L LO Pressure Trip1.5 bar
AIR DRYER & MOISTURE SEPARATION
DRYER CONTROLS
DESICCANT DRYER
Dryer StatusSTANDBY
Dew Point-- °C
Inlet Pressure-- bar
Tower A / BA ACTIVE
MOISTURE SEPARATORS
Inter-Stage Sep.CLEAR
After-Stage Sep.CLEAR
Auto Drain Inter-Stage
Auto Drain After-Stage
MANUAL DRAIN
Inter-Stage Drain
After-Stage Drain
Bottle 1 Drain
Bottle 2 Drain
SAFETY VALVES & RELIEF DEVICES
SAFETY VALVE STATUS
BOTTLE SAFETY VALVES
SV — Bottle 1CLOSED · 32 bar
SV — Bottle 2CLOSED · 32 bar
Last Test — SV1--
Last Test — SV2--
COMPRESSOR SAFETY VALVES
SV — Stage 1 C1CLOSED · 10 bar
SV — Stage 2 C1CLOSED · 33 bar
SV — Stage 1 C2CLOSED · 10 bar
SV — Stage 2 C2CLOSED · 33 bar
BURSTING DISCS
Disc — Intercooler C1INTACT · 12 bar
Disc — Intercooler C2INTACT · 12 bar
TEST FUNCTIONS
Per SOLAS II-1/Reg.26 — test each survey period
AUTOMATIC CONTROL — START/STOP SEQUENCES
AUTO CONTROL SETTINGS
COMPRESSOR AUTO START/STOP
Auto Start Set Point25 bar
Auto Stop Set Point30 bar
Lead CompressorNo.1
Auto Mode
SETPOINT ADJUSTMENT
Start Setpoint (bar)
Stop Setpoint (bar)
LEAD/LAG CHANGEOVER
Lead Selection
Auto Changeover
Changeover Interval24 h
SEQUENCE LOG

Screen Too Small

This simulator requires a minimum resolution of 980 x 600 px.
Recommended: 1920 x 1080 (16:9) or larger.