ENGINE PARAMETERS

Pumps / Services

Engine State
STOPPED
SINGLE LINE DIAGRAM — DG-1
DIESEL ENGINE W6L20 0 RPM CPLG GENERATOR 0.0 kV 0.0 Hz 0 kW PF: 0.00 BKR OPEN 450V BUSBAR LIGHTING PUMPS HVAC COMP LO PRESS: 0.0 bar CW TEMP: 25°C FO PRESS: 0.0 bar EXH TEMP: 25°C POWER FACTOR: 0.00 LOAD: 0% MCR STOPPED
ALARMS & CONTROL
BREAKER OPEN
SYNC CHECK: IDLE
RUNNING LOG
Run Hours (session)0.0h
Starts (session)0

System ready.
LOAD MONITORING
Active Load0%
kW Output0kW
kVAR0kVAR
Current0A
START AIR & FUEL
Start Air Bottle30.0bar
FO Service Tank98%

ENGINE P&ID — COMBUSTION & MECHANICAL SYSTEMS
ENGINE CONTROLS
ENGINE PARAMETERS
Speed0 RPM
Exhaust Temp25°C
Charge Air Press0.0 bar
TurbochargerIDLE
Cyl CondNORMAL
GOVERNOR
Speed Setpoint
0%
Hz Selection
PIPELINE COMPONENTS
FUEL OIL SYSTEM — P&ID
FUEL CONTROLS
FUEL OIL PARAMETERS
FO Pressure0.0 bar
FO Temp25°C
Viscosity— cSt
Service Tank Level98%
Settling Tank Level—%
PUMPS & VALVES
FUEL GRADE
COOLING WATER SYSTEM — P&ID
COOLING CONTROLS
FRESH WATER CIRCUIT
HT CW Outlet25°C
HT CW Inlet25°C
LT CW Outlet25°C
Expansion Tank—%
FW PumpSTOPPED
SEA WATER CIRCUIT
SW Inlet Temp20°C
Central Cooler DP0.0 bar
SW PumpSTOPPED
PUMPS & THERMOSTAT
Thermostat Setpoint
85°C
LUBRICATING OIL SYSTEM — P&ID
LUBE OIL CONTROLS
LO PARAMETERS
LO Pressure0.0 bar
LO Temp (before cooler)25°C
LO Temp (after cooler)25°C
Sump Level—%
LO Filter DP0.0 bar
PUMPS & SERVICES
LO THERMOSTAT
Temp Setpoint
55°C
START AIR SYSTEM — P&ID
START AIR CONTROLS
AIR BOTTLES
No.1 Air Bottle30.0 bar
No.2 Air Bottle30.0 bar
Working Air Press7.0 bar
Control Air Press6.5 bar
COMPRESSORS
START SEQUENCE
Turning GearDISENGAGED
Indicator CocksCLOSED
Prelube Timer
GOVERNOR & SPEED CONTROL
GOVERNOR CONTROLS
SPEED CONTROL
Actual Speed0 RPM
Setpoint Speed0 RPM
Speed Droop4%
Fuel Rack Pos0%
Speed Setpoint
0%
FREQUENCY
FREQUENCY 0.0 Hz
Hz Selection
GOVERNOR MODE
GENERATOR — ELECTRICAL OUTPUT
GENERATOR CONTROLS
OUTPUT PARAMETERS
FREQUENCY 0.0 Hz
Voltage (L-L)0.0 kV
Active Power0 kW
Reactive Power0 kVAR
Power Factor0.00
Load % MCR0%
Stator Temp25°C
Bearing Temp25°C
VOLTAGE REGULATION
AVR Setpoint
450V
Load Demand
0%
BREAKER
BREAKER OPEN
SYNC CHECK: IDLE
MAIN SWITCHBOARD — 450V BUSBAR
SWITCHBOARD CONTROLS
BUSBAR STATUS
Busbar Voltage0 V
Busbar Frequency0.0 Hz
Total Load0 kW
Total Current0 A
FEEDER BREAKERS
BUS TIE
Bus-tie BreakerOPEN
PARALLEL OPERATION & LOAD SHARING
LOAD SHARING CONTROLS
DG-1 (THIS UNIT)
Load0 kW
Load %0%
Frequency0.0 Hz
DG-2 (RUNNING MACHINE)
Load0 kW
Load %0%
Frequency0.0 Hz
Voltage0.0 kV
SYNCHRONISING
SYNCHROSCOPE: IDLE
Phase Difference—°
Volt Difference— V
Freq Difference— Hz
Load Transfer
50%