BURNER MANAGEMENT
BMS STATUS
BMS OFFLINE
Mode MANUAL

FEED PUMP
Feed Pump A

AUTO / MANUAL

PRESSURE SETPOINT

BLOW-DOWN
BOILER P&ID SCHEMATIC
STEAM DRUM NWL STEAM SPACE 0.0 bar FURNACE NO FLAME FO SUPPLY FO RETURN FO TEMP 45°C FEED WATER FP MAIN STEAM MSV SV 7.3b BLOW-DOWN FLUE GAS FLUE TEMP 30°C VENT NRV O₂% -- —— Steam/Water —— Fuel Oil - - - Flue Gas SCENARIO: -- Select a scenario to begin
ALARMS & STATUS
LIVE READINGS
Steam Pressure0.0bar
Drum LevelNWL
Feed Water Flow0kg/h
FO Temperature45°C
Flue Gas Temp30°C
O₂ in Exhaust--%
ACTIVE ALARMS
VALVE LINEUP
STEAM VALVES
FEED WATER
FUEL OIL
BLOW-DOWN
NRV STATUS
STEAM PRESSURE TREND
STARTUP CHECKLIST
Open FW suction valve
Start feed pump
Open feed check valve
Open FO supply valve
Open FO return valve
FO temp >120°C
Start burner
Pressure >4.5 bar
Open main steam stop
Switch to AUTO mode
DRUM & COMBUSTION P&ID
DRUM PARAMETERS
STEAM DRUM
Drum Pressure0.0 bar
Drum Temperature-- °C
Water LevelNWL
Steam Output0 kg/h
COMBUSTION
Burner StateOFF
Firing Rate0 %
Air/Fuel Ratio--
Furnace Pressure-- mbar
CONTROL MODE
Pressure SP6.0 bar
FUEL OIL SYSTEM — P&ID
FUEL CONTROLS
FUEL OIL SUPPLY
FO Temperature45 °C
FO Pressure-- bar
FO Flow Rate0 kg/h
Viscosity-- cSt
FUEL VALVES
FO Supply
FO Return
HEATER
Heater StatusOFF
Target Temp120 °C
FUEL TYPE
Active FuelHFO
COMBUSTION MANAGEMENT — BURNER DETAIL
COMBUSTION CONTROLS
BURNER STATUS
BMS StateOFFLINE
IgnitionOFF
Flame DetectedNO
Purge Status--
AIR SUPPLY
FD FanOFF
Air Flow0 kg/h
Damper Position0 %
COMBUSTION QUALITY
O₂ in Flue Gas-- %
CO ppm-- ppm
Flue Temp30 °C
Efficiency-- %
FIRING RATE
Current Rate0 %
Manual firing rate override (burner must be running)
FEEDWATER SYSTEM — P&ID
FEEDWATER CONTROLS
FEED PUMPS
Pump AOFF
Pump B (Standby)STANDBY
Flow Rate0 kg/h
Discharge Press-- bar
LEVEL CONTROL
Drum LevelNWL
Level Switch LoNORMAL
Level Switch LoLoNORMAL
Feed Control Valve-- %
FEED VALVES
FW Suction
Feed Check NRV
ECONOMISER
Eco Inlet Temp-- °C
Eco Outlet Temp-- °C
Heat Recovery-- kW
STEAM DISTRIBUTION — P&ID
STEAM SYSTEM CONTROLS
STEAM HEADER
Header Pressure0.0 bar
Header Temp-- °C
Steam Flow0 kg/h
Steam Quality-- %
MAIN STEAM STOP VALVE
MSV PositionCLOSED
CONSUMERS
Heating CoilsOFF
FO HeaterOFF
Tank HeatingOFF
Soot BlowerIDLE
PRESSURE REDUCING
PRV Inlet-- bar
PRV Outlet-- bar
PRV Position--
BLOW-DOWN SYSTEM
BLOW-DOWN CONTROLS
BOTTOM BLOW-DOWN
Valve StatusCLOSED
Last Blowdown--
Duration-- s
SURFACE BLOW-DOWN
Valve StatusCLOSED
Continuous Rate-- kg/h
WATER ANALYSIS
TDS-- ppm
pH--
Chlorides-- ppm
Blowdown Rec.NORMAL
FLASH TANK
Flash Tank Press-- bar
Flash Steam-- kg/h
SAFETY VALVE ARRANGEMENT — SOLAS II-1/R.35
SAFETY SYSTEM STATUS
SAFETY VALVE 1 — DRUM
Set Pressure7.3 bar
StatusCLOSED
Last Lifted--
Accumulation Test--
SAFETY VALVE 2 — SUPERHEATER
Set Pressure7.0 bar
StatusCLOSED
Last Lifted--
PRESSURE SWITCH INTERLOCKS
PSH Burner Cutout6.8 bar — OK
PSHH ESD7.1 bar — OK
PSL Feed Pump4.0 bar — OK
BMS INTERLOCKS
Low Water LLNORMAL
Flame FailureNORMAL
High PressNORMAL
Low FO PressNORMAL
ESD
BOILER WATER TREATMENT SYSTEM
WATER CHEMISTRY
BOILER WATER ANALYSIS
pH--
TDS-- ppm
Chlorides-- ppm
Hardness-- ppm
Phosphate-- ppm
FEED WATER
Feed pH--
Feed Conductivity-- μS/cm
O₂ Content-- ppb
CHEMICAL DOSING
Oxygen Scavenger-- ml/h
Scale Inhibitor-- ml/h
Alkalinity Agent-- ml/h
DEAERATOR
DA Pressure-- bar
DA Temperature-- °C
Storage Level--
EXHAUST GAS SYSTEM & EMISSIONS
EXHAUST MONITORING
FLUE GAS ANALYSIS
O₂-- %
CO₂-- %
CO-- ppm
NOₓ-- mg/m³
SO₂-- mg/m³
TEMPERATURES
Flue at Drum-- °C
Flue at Economiser-- °C
Stack Outlet-- °C
Acid Dewpoint-- °C
DRAUGHT
Furnace Draft-- Pa
Stack Draft-- Pa
ID Fan Status--
SOOT BLOWING
Soot BlowerIDLE
Last Operation--

Screen Too Small

This simulator requires a minimum resolution of 980 x 600 px.
Recommended: 1920 x 1080 (16:9) or larger.
Please resize your browser window or use a larger display.