FSS Code Ch.5 §4.2 — fans must stop before release
All 6 boundary dampers confirmed CLOSED — visual check
FSS Code Ch.5 §4.2 — dampers confirmed by indicator lights
All access doors to protected space closed and clipped
FSS Code Ch.5 §4.2.3
MACHINERY ISOLATION
Fuel oil quick-closing valves confirmed shut
SOLAS II-2/Reg.17 — fuel isolation before CO₂ release
Main engine and generators stopped if safe to do so
FSS Code Ch.5 §3.4 — CO₂ is non-conducting, safe for live equipment
Emergency power source confirmed available (EDG)
SOLAS II-1/Reg.43 — emergency power during flooding
NOTIFICATIONS
Bridge / Officer of the Watch notified
SMS Fire Fighting Plan §4.1
CO₂ room door accessible — abort pull-box unobstructed
FSS Code Ch.5 §4.3.3 — abort available during 20s delay
0/12 items confirmed — discharge LOCKED
REGULATORY REFERENCE
SOLAS REQUIREMENTS
II-2/Reg.10 — Fire-extinguishing systems
II-2/Reg.17 — Fuel isolation before flooding
II-2/Reg.19 — Crew training requirements
FSS CODE
Ch.5 §3 — System design requirements
Ch.5 §4 — Operating procedures
Ch.5 §4.2 — Ventilation and dampers
Ch.5 §4.3 — Discharge sequence
IACS UR F15
Cylinder quantity calculation
Pipe sizing and nozzle design
Low-pressure alarm requirement
Annual inspection and weighing
CO₂ HAZARD DATA
IDLH: 40,000 ppm (4% v/v)
Extinguishing conc: 34% v/v min
Design conc: 40% v/v
Re-entry: SCBA mandatory
TREND DISPLAY — SYSTEM PARAMETERS
TREND SELECTION
ACTIVE TRENDS
CO₂ Concentration0.04% v/v
System Pressure57.4 bar
Reserve Pressure56.8 bar
Cylinders Remaining72
TIME BASE
PEAK VALUES
Peak CO₂ Conc0.04%
Min Sys Pressure57.4 bar
Max Cylinders Disch0
CO₂ FIXED FIRE SUPPRESSION
High-pressure CO₂ total flooding system — Engine Room / Cargo Pump Room
SOLAS II-2/Reg.10 • FSS Code Ch.5 • IACS UR F15