EC CELL — POWER & TRO STATUS
EC CELL — C-101STANDBY
Current
0 A
Voltage
0.0 V
Power
0 kW
Cell Temp
28°C
Salinity
34 PSU
Efficiency
100%
Electrode Pairs (3 sets)
Rated: 3000 A · 10.5 V · 31.5 kW · TRO output: 5–15 mg/L
TRO MONITORING
CELL OUTLET
0.00
mg/L
IN TANK
0.00
mg/L
DISCHARGE
0.00
mg/L
NEUTRALISER — Na₂S₂O₃OFF
Tank Level
85%
Dose Rate
0 L/h
TRO After
—
BALLAST PUMP — P-101
Flow
0 m³/h
Press
0.0 bar
Power
0 kW
BALLAST TANKS — SELECT
TREATED VOLUME
0
m³ treated this voyage
HOLD TIME
0.0 h (min 24h required)
P&ID — ELECTROCHLORINATION BALLAST WATER TREATMENT SYSTEM
0 ACTIVE
IMO D-2 DISCHARGE CRITERIA
| PARAMETER | LIMIT | NOW | OK? |
|---|
USCG ADDITIONAL
| PARAMETER | LIMIT | NOW | OK? |
|---|
DISCHARGE AUTHORISATION
AUTHORISED
All D-2 parameters within limits
EC SYSTEM PARAMETERS
TRO in tank: 1–3 mg/L (target)
TRO at discharge: <0.2 mg/L (USCG)
Cell temp max: 45°C
Min salinity: 10 PSU (reduced efficacy)
Na₂S₂O₃ ratio: 7.9 mg per 1 mg TRO
Electrode cleaning: every 3 months
TRO at discharge: <0.2 mg/L (USCG)
Cell temp max: 45°C
Min salinity: 10 PSU (reduced efficacy)
Na₂S₂O₃ ratio: 7.9 mg per 1 mg TRO
Electrode cleaning: every 3 months
EC CELL CONTROL
CURRENT SETPOINT
2000 A
PUMP OPERATION
NEUTRALISATION
Required when TRO at discharge > 0.2 mg/L
ELECTRODE CLEANING