CONTROLS
WARNING — WITHIN 12nm — PRODUCTION RESTRICTED
EJECTOR PUMP

DISTILLATE PUMP

SALINOMETER
SALINITY
--
ppm

DISTILLATE ROUTE
— FW TANK

POSITION
51°12'N 003°45'E
Distance from land:
45.2 nm

PIPELINE COMPONENTS
FWG FLOW DIAGRAM — PLATE/SHELL TYPE
SEA WATER SUPPLY SEA CHEST EP CONDENSER SW OUT CONDENSATE EVAPORATOR VACUUM -- mbar --°C JCW INLET JCW OUTLET JCW IN 85°C JCW OUT 80°C BRINE TO SEA BRINE EJ SALINOMETER -- ppm 3-WAY FW TANK -- DIVERT TO OVERBOARD DP SCENARIO: -- Select scenario to begin
GAUGES & ALARMS
LIVE READINGS
JCW Inlet Temp85°C
JCW Outlet Temp80°C
Vacuum0mbar
Evap. Temperature--°C
Salinity--ppm
Production Rate0t/day
FW Tank Level30%

ACTIVE ALARMS
VALVE LINEUP
COOLING WATER
DISTILLATE
BRINE EJECTOR
VACUUM & SALINITY TREND
PRODUCTION LOG
PARAMETERS
Total Produced0.00 t
JCW ΔT0°C
Rated Output26 t/day
Distillate Route--

FWG SYSTEM P&ID — FULL CIRCUIT
SYSTEM LINEUP
OPERATING STATUS
Ejector PumpSTOPPED
Distillate PumpSTOPPED
SalinometerOFF
Production Rate0 t/day
Running Hours0.0 h
QUICK ACTIONS
EVAPORATOR — HEAT TRANSFER SECTION
EVAPORATOR CONTROLS
JCW HEAT SOURCE
JCW Inlet Temp85°C
JCW Outlet Temp80°C
JCW ΔT5°C
Heat Input-- kW
EVAPORATION CONDITIONS
Vacuum-- mbar
Evap. Temperature--°C
Boiling Point--°C
Feed Water Flow-- m³/h
JCW VALVE
CONDENSER — VAPOUR RECOVERY SECTION
CONDENSER CONTROLS
COOLING WATER
SW Inlet Temp-- °C
SW Outlet Temp-- °C
SW Flow Rate-- m³/h
CONDENSATE OUTPUT
Condensate Flow-- l/h
Condensate Temp--°C
Efficiency--%
SW COOLING VALVE
EJECTOR SYSTEM — VACUUM & BRINE EXTRACTION
EJECTOR CONTROLS
EJECTOR PUMP
StatusSTOPPED
Discharge Pressure-- bar
Seawater Flow-- m³/h
BRINE EJECTOR
Brine Concentration-- g/l
Brine Flow-- l/h
Brine Ejector ValveCLOSED
VACUUM STATUS
System Vacuum-- mbar
Air Ejector StatusINACTIVE
FEED WATER SYSTEM — SEAWATER SUPPLY
FEED WATER CONTROLS
SEA CHEST
Sea Chest Pressure-- bar
Sea Temperature-- °C
Sea Salinity35 g/l
FEED FLOW
Feed ValveCLOSED
Feed Flow Rate-- m³/h
Feed Temperature--°C
POSITION & RESTRICTION
Position-- nm
12nm StatusCLEAR
DISTILLATE SYSTEM — COLLECTION & ROUTING
DISTILLATE CONTROLS
DISTILLATE PUMP
StatusSTOPPED
Flow Rate-- l/h
Discharge Pressure-- bar
ROUTING — THREE-WAY VALVE
Current Route-- OVERBOARD
FW Tank to FW TankCLOSED
Overboard ValveCLOSED
PRODUCTION
Production Rate0 t/day
Total Produced0.00 t
CHEMICAL DOSING — SCALE & BIOCIDE TREATMENT
DOSING CONTROLS
ANTI-SCALE DOSING
Pump StatusOFF
Dose Rate-- ml/h
Tank Level-- %
BIOCIDE DOSING
Pump StatusOFF
Dose Rate-- ml/h
Tank Level-- %
SCALE INDICATOR
Scale Index--
Last Clean--
SALINITY MONITORING — SALINOMETER SYSTEM
SALINOMETER CONTROLS
SALINOMETER
CURRENT SALINITY
--
ppm (LIMIT: 2 ppm)
StatusOFF
Alarm Setpoint2 ppm
Alarm StatusNORMAL
THREE-WAY DIVERT VALVE
Valve PositionOVERBOARD
Auto-divertENABLED
CALIBRATION
Last Calibration--
Cal. Due--

Screen Too Small

This simulator requires a minimum resolution of 980 x 600 px.
Recommended: 1920 x 1080 (16:9) or larger.
Please resize your browser window or use a larger display.