⚠ PORT RESTRICTION ACTIVE — MARPOL ANNEX V — INCINERATION PROHIBITED IN PORT ⚠
PROCESS VALUES
PRI CHAMBER---°C
SEC CHAMBER---°C
FLUE GAS TEMP---°C
SLUDGE FLOW0.0kg/h
COMB AIR FLOW0%
COOLING WATER--°C
SLUDGE PRESS0.0bar

Vessel Position
AT SEA — INCINERATION PERMITTED
P&ID SCHEMATIC — INCINERATOR OG 200C
PRIMARY CHAMBER 🔥 --- °C SECONDARY CHAMBER --- °C TARGET >900°C AFTERBURNER STACK ---°C SLUDGE OIL TANK 75% SLUDGE OIL COMB AIR FAN STOP COMB AIR COOLING WATER --°C WASTE FEED CLOSED TEMP HOLD MARPOL ANNEX VI — IMO MEPC.76(40) — ANNEX V / ANNEX I PRIMARY: 850–1000°C | SECONDARY: >900°C | FLUE MAX: 350°C TI-101 TI-102 TI-103
ALARM MANAGEMENT SYSTEM
ESD shuts all burners, closes fuel valves, trips fan
SYSNo active alarms
PIPELINE LINEUP
SLUDGE OIL INLETCLOSED
ATOMISING AIRCLOSED
COOLING WATERCLOSED
FLUE DAMPERCLOSED
AIR FANSTOPPED
SWC BURNEROFF
OWC BURNEROFF
VESSEL POSITIONAT SEA
OPERATION LOG & GARBAGE RECORD BOOK
--:--:-- System initialised. Awaiting scenario selection.
SCENARIO
NORMAL OPERATIONS
All systems nominal. Awaiting start-up.
INCINERATOR P&ID — COMBUSTION CHAMBERS & CONTROLS
COMBUSTION CONTROLS
COMBUSTION SYSTEM
AIR FAN
SWC BURNER
OWC BURNER
VALVES
SLUDGE INLET
ATOMISING AIR
COOLING WATER
FLUE DAMPER
TEMPERATURES
Primary Chamber--- °C
Secondary Chamber--- °C
Flue Gas--- °C
INTERLOCKS
Min Temp Interlock ARMED
Port Restriction CLEAR
ESD Status RESET
COMBUSTION MONITORING — CHAMBER TEMPERATURES & AIR MANAGEMENT
COMBUSTION PARAMETERS
CHAMBER STATUS
Primary Chamber--- °C
Target (Min)850 °C
Secondary Chamber--- °C
Target (Min)900 °C
Residence Time-- s
AIR MANAGEMENT
Combustion Air0 %
Excess Air-- %
Fan SpeedSTOP
HEAT RELEASE
Thermal Input-- kW
Heat Load-- %
REGS — MEPC.76(40)
Primary ≥ 850°C--
Secondary ≥ 900°C--
Res. Time ≥ 0.3 s--
FUEL SYSTEM — OIL SUPPLY & BURNER MANAGEMENT
FUEL CONTROLS
SWC BURNER — SOLID WASTE
SWC Burner
Waste Feed DoorCLOSED
Waste Load-- kg
OWC BURNER — SLUDGE OIL
OWC Burner
Sludge Flow0.0 kg/h
Oil Pressure0.0 bar
SLUDGE FLOW SETPOINT
0 kg/h
VALVES
SLUDGE INLET
ATOM AIR
SLUDGE TANK
Tank Level75 %
Tank Volume-- m³
Pipeline components:
SLUDGE FEED SYSTEM — OIL TRANSFER & ATOMISATION
SLUDGE CONTROLS
FEED PUMP
Sludge Pump
Pump StatusSTOPPED
Discharge Pressure0.0 bar
ATOMISATION
Atomising Air
Atom. Air Pressure0.0 bar
Nozzle StatusCLOSED
FLOW CONTROL
0 kg/h
Actual Flow0.0 kg/h
Flow Error0.0 kg/h
ANNEX I COMPLIANCE
Sludge OriginMACHINERY SPACE
MARPOL Annex ICOMPLIANT
Oil Content-- ppm
EXHAUST GAS SYSTEM — STACK & FLUE GAS TREATMENT
EXHAUST CONTROLS
STACK CONDITIONS
Flue Gas Temp--- °C
Stack Draft-- Pa
Flue Damper
COOLING WATER
Cooling Water
Inlet Temp-- °C
Outlet Temp-- °C
Flow Rate-- m³/h
FLUE GAS LIMITS
Max Stack Temp350 °C
Current Temp--- °C
Temp Status--
ASH HANDLING — RESIDUE MANAGEMENT & DISPOSAL
ASH CONTROLS
ASH ACCUMULATION
Grate Ash Level-- %
Bottom Ash Temp-- °C
Fly Ash Collector-- %
ASH REMOVAL
Grate Clinker
Fly Ash Drain
GRB — GARBAGE RECORD BOOK
MARPOL ANNEX V — CATEGORY E: Incinerator Ash
No GRB entries yet.
LOG WASTE ENTRY
0.5
SAFETY SYSTEMS — INTERLOCKS & PROTECTION
SAFETY STATUS
INTERLOCK STATUS
Min Temp (850°C)ARMED
Fan RunningREQUIRED
Port RestrictionCLEAR
High Temp (1200°C)ARMED
ESD CHAIN
ESD StatusRESET
Last Trip CauseNONE
MARPOL COMPLIANCE
Annex V Prohibition--
Vessel in PortNO
GRB Up to Date--
ACTIVE ALARMS
SYSNo active alarms
EMISSIONS MONITORING — FLUE GAS ANALYSIS
EMISSIONS DATA
FLUE GAS COMPOSITION
O₂-- %
CO₂-- %
CO-- ppm
NOₓ-- mg/m³
SO₂-- mg/m³
Particulates-- mg/m³
ANNEX VI LIMITS
NOₓ Limit-- mg/m³
NOₓ Status--
SO₂ Limit-- mg/m³
SO₂ Status--
Opacity-- %
STACK TEMPERATURE
Stack Outlet--- °C
Limit350 °C
Status--
CONTINUOUS MONITORING
CEMS Active
Last Sample--:--

Screen Too Small

This simulator requires a minimum resolution of 980 x 600 px.
Recommended: 1920 x 1080 (16:9) or larger.
Please resize your browser window or use a larger display.