Enclosed Space Entry Gas Testing
Pre-entry atmosphere testing of tanks, cofferdams and void spaces per IMO Resolution A.1050(27) and SOLAS XI-1/7
Four-gas pump-aspirated confined space monitor: combustible %LEL, oxygen vol%, carbon monoxide ppm and hydrogen sulfide ppm. This is the instrument class that draws its sample down a hose, so every reading arrives late — and the trainee has to learn to wait the transit out, survey a space at more than one level, and recognise a flow failure instead of trusting a frozen display. Aligned to enclosed space entry practice under IMO Resolution A.1050(27) and SOLAS XI-1/7.
Pre-entry atmosphere testing of tanks, cofferdams and void spaces per IMO Resolution A.1050(27) and SOLAS XI-1/7
Permit-to-work atmospheric testing for vessel entry, excavation and hot work in upstream and downstream facilities
Remote sampling of reactors, columns and storage vessels before entry, where the atmosphere is stratified and unbreathable
A generic training model of a pump-aspirated four-gas confined space monitor. Inspired by instruments of this class; not affiliated with, endorsed by, or a reproduction of any manufacturer's product, and no manufacturer's marks are used.
This simulator is part of the full BlueSim suite. Book a guided demo and we’ll walk you through it.