AFF exit exam questions and answers — Set 2
Set 2 of the Advanced Fire Fighting (AFF) exit exam bank — 30 of 218 questions, with the correct option marked and a one-line explanation for every one. Read it end to end, jump to a single set, or search it — then sit the same bank as a timed paper. The real DG Shipping exit exam is 30 marks with 15 to pass.
These are the bank's original groupings. Practising deals the whole bank out again every time you reshuffle, so a practice “Set 3” is a different 30 questions each time — the set numbers below are the source file's, and are only used here so the key stays navigable. Options are listed in their original order with fixed letters; when you practise, those move too.
Bank last rebuilt .
30 of 30 shown · Set 2
Nothing in this set matches that. Try a shorter word, or search the whole key.
Set 2 — 30 AFF exit exam questions with answers
1. Regarding deck and engine room operational protocols in Advanced Fire Fighting, what is the mandatory safety standard required under STCW Code Table A-VI/2?
- A. Non-mandatory recommendation
- B. Optional compliance based on crew discretion
- C. Applicable only when vessel is anchored
- D. Full compliance with approved STCW safety procedures and SMS protocols
2. What is the primary function of the emergency fire pump isolation valve located on the main deck?
- A. Divert water to the bilge system
- B. Prevent backflow to the sea chest
- C. Increase water pressure to the bridge
- D. Isolate the engine room fire main from the deck fire main
3. Under SOLAS regulations, what is the minimum water capacity for the emergency fire pump on cargo vessels?
- A. At least 25 m³/h or 40% of required main pump capacity
- B. 10 m³/h fixed rate
- C. 50 m³/h continuous flow
- D. 100 m³/h at maximum RPM
4. What type of fixed fire extinguishing system is required for paint lockers having a deck area greater than 4 m²?
- A. Inert gas generator
- B. High-expansion foam only
- C. Dry powder system only
- D. Fixed CO2 or water-sprinkling fire extinguishing system
5. What pre-release protocol must be completed before discharging CO2 into an engine room space?
- A. Ensure all personnel are evacuated, ventilation fans stopped, and dampers closed tight
- B. Open skylights to vent pressure
- C. Start emergency generator
- D. Keep exhaust ventilation running at half speed
6. What is the principal extinguishing mechanism of High-Expansion Foam when applied to machinery space bilges?
- A. Absorbing oil spills
- B. Cooling hot steel bulkheads
- C. Rapid volume filling and total smothering of flammable surface vapors
- D. Diluting fuel vapors
7. What is the maximum allowable pressure drop before an SCBA compressed air cylinder must be recharged?
- A. 25% below working pressure
- B. 5 bar drop
- C. 50% below working pressure
- D. 10% below nominal working pressure
8. What is the function of the International Shore Connection fitted on shipboard fire mains?
- A. Discharge oily bilge water to shore
- B. Enable shore fire lines to connect to the vessel's fire main regardless of port hose fittings
- C. Bunker fresh water from shore
- D. Supply shore electrical power
9. What is the primary objective of boundary cooling during a shipboard compartment fire?
- A. Prevent heat transfer through bulkheads and decks to stop fire spread to adjacent spaces
- B. Extinguish the primary fire flame
- C. Cool the firefighting team's turnout suits
- D. Reduce water pressure in the fire main
10. Under SOLAS Chapter II-2, how many firefighter outfits must be carried on cargo ships of 500 GT and above?
- A. At least 6 outfits
- B. At least 2 firefighter outfits
- C. At least 4 outfits
- D. At least 1 outfit
11. What safety precaution is mandatory when entering a compartment after a fixed CO2 system has been discharged?
- A. Wait 5 minutes without testing
- B. Verify complete gas-freeing and atmospheric testing (O2 at 20.9%) using approved sensors
- C. Enter immediately after opening door
- D. Wear a cotton dust mask only
12. What is the purpose of the relief valve fitted on a fire main isolation system?
- A. Drain water during freezing weather
- B. Supply water to deck scuppers
- C. Allow air to vent from the system
- D. Protect fire piping from over-pressurization during emergency pump operation
13. Which SOLAS requirement applies to quick-closing valves on fuel oil tanks in case of engine room fire?
- A. They must be tested every 5 years
- B. They can only be operated manually inside the engine room
- C. They must be capable of being closed from a safe position outside the engine room
- D. They must close automatically at 50 degrees C
14. What is the minimum operating duration required for an approved SCBA cylinder used in firefighting?
- A. At least 30 minutes
- B. 60 minutes
- C. 15 minutes
- D. 45 minutes
15. What type of foam compound is most effective for extinguishing polar solvent alcohol fires on chemical tankers?
- A. Alcohol-Resistant Aqueous Film-Forming Foam (AR-AFFF)
- B. High-Expansion Synthetic Foam
- C. Fluoroprotein Foam
- D. Standard Protein Foam
16. Why must fire hoses be pressure tested annually onboard ships?
- A. To verify structural integrity and prevent hose burst under emergency working pressure
- B. To clean internal salt deposits
- C. To satisfy customs inspections
- D. To measure water flow rate
17. What is the main advantage of a water mist fire extinguishing system compared to traditional sprinkler systems?
- A. Requires no pumps or piping
- B. Fills the space with chemical powder
- C. Requires higher electrical voltage
- D. Uses significantly less water while providing high heat absorption and rapid oxygen displacement
18. Under STCW, what is the role of the On-Scene Commander during a major shipboard fire incident?
- A. Operate the main engine throttle
- B. Maintain passenger headcount in mess room
- C. Direct tactical firefighting operations at the fire scene and communicate with the Command Team
- D. Stay on the bridge to navigate the ship
19. What safety feature prevents accidental discharge of fixed CO2 fire extinguishing systems?
- A. Automatic trigger at 30°C
- B. Double-valve protection with pilot control and alarm trip switches in locked release cabinets
- C. Threaded cap on main discharge pipe
- D. Single push button on the bridge
20. What device must be worn by firefighters in low oxygen or toxic smoke environments?
- A. Dust filter mask
- B. Canister gas mask
- C. Wet handkerchief
- D. Self-Contained Breathing Apparatus (SCBA)
21. How often must emergency fire pumps be tested operational according to SOLAS safety management system routines?
- A. Monthly
- B. Annually
- C. Quarterly
- D. Weekly
22. What is the correct procedure for searching a smoke-filled compartment during search and rescue?
- A. Crawl along ceiling piping
- B. Run to the far corner immediately
- C. Maintain continuous physical or wall contact and sweep floor area systematically
- D. Walk upright quickly with flashlight
23. What is the primary function of drenching systems fitted on roll-on/roll-off (Ro-Ro) vehicle decks?
- A. Provide rapid total-area water coverage to extinguish vehicle fires quickly
- B. Cool exhaust manifolds
- C. Wash down vehicle tires
- D. Provide fresh drinking water
24. Which class of fire involves energized electrical equipment such as switchboards or electric motors?
- A. Class B
- B. Class A
- C. Class C (or Electrical Fire)
- D. Class D
25. Why must firefighter turnout gear be thoroughly cleaned after exposure to heavy smoke?
- A. To increase thermal weight
- B. To remove carcinogenic combustion products and flammable chemical residues
- C. To restore shiny color
- D. To shrink the material tight
26. What is the purpose of a flame arrestor fitted on a fuel tank vent pipe?
- A. Regulate fuel pumping speed
- B. Prevent external flames from traveling into the fuel vapor space
- C. Stop fuel overflow
- D. Filter air dust
27. What is the minimum number of spare SCBA air charges required onboard cargo ships?
- A. None required if compressor available
- B. 5 spare charges per set
- C. At least 2 spare charges per required SCBA set
- D. 1 spare charge total
28. A safety is provided on the CO2 discharge piping to prevent:
- A. Rupture of cylinder due to temperature increase
- B. Over pressurization of the space being flooded
- C. Flooding of a space where personnel are present
- D. Over pressurization of the CO2 discharge piping
29. Apart from red what other color is frequently used for a CO2 extinguisher:
- A. Yellow
- B. Blue
- C. Black
- D. Red
30. In fighting a fire in a fuel tank, the first action you should attempt is to:
- A. Station someone at the fixed CO2 release controls
- B. Begin transferring the fuel to other tanks
- C. Top off the tank to force out all vapors
- D. Secure all sources of fresh air to the tank