AFF exit exam questions and answers — Advanced Fire Fighting
All 517 questions from the Advanced Fire Fighting (AFF) exit exam bank, with the correct option marked and a one-line explanation for every one. Read it end to end, jump to a single set, or search it — then sit the same bank as a timed paper. The real DG Shipping exit exam is 30 marks with 15 to pass.
These are the bank's original groupings. Practising deals the whole bank out again every time you reshuffle, so a practice “Set 3” is a different 30 questions each time — the set numbers below are the source file's, and are only used here so the key stays navigable. Options are listed in their original order with fixed letters; when you practise, those move too.
Bank last rebuilt .
517 of 517 shown
Nothing in this key matches that. Try a shorter word, or search the whole key.
Set 1 — 30 AFF exit exam questions with answers
1. What is the primary purpose of boundary cooling during a fire on a ship?
- A. To minimize smoke production
- B. To accelerate the combustion process
- C. To increase the temperature inside the compartment
- D. To prevent fire spread by cooling adjacent surfaces
2. In advanced firefighting, what is the purpose of using a Class A foam?
- A. To neutralize acidic fumes
- B. To control oil and fuel fires
- C. To cool down hot surfaces
- D. To suppress flammable gas release
3. During a firefighting operation, what does the term "smoke curtain" refer to?
- A. A cloud of water droplets to control temperature
- B. A curtain made of fire-resistant material to contain smoke
- C. A warning signal for evacuation
- D. A physical barrier to prevent the entry of firefighters
4. Which firefighting equipment is specifically designed for use in confined spaces onboard a ship?
- A. Foam monitors
- B. Fire extinguishers
- C. Fire hoses
- D. Breathing apparatus
5. What is the primary purpose of the International Shore Connection (ISC) on a ship?
- A. To connect with the shore power supply
- B. To supply freshwater to the crew
- C. To enhance communication with nearby vessels
- D. To facilitate shore-based firefighting assistance
6. In advanced firefighting, what is the purpose of using a water fog nozzle?
- A. To increase the range of water projection
- B. To create a visual signal for distress
- C. To create a dense fog for cooling purposes
- D. To generate a fine mist for fire suppression
7. What is the role of a fire blanket in firefighting?
- A. To smother small fires by cutting off the oxygen supply
- B. To cool down hot surfaces in a fire-affected area
- C. To create a barrier against radiant heat
- D. To provide an escape route for trapped personnel
8. In the context of firefighting, what does the acronym PASS stand for?
- A. Pull, Aim, Squeeze, Sweep
- B. Pressure Application Safety System
- C. Portable Aqueous Suppression System
- D. Primary Air Supply Source
9. What is the purpose of a fire screen in advanced firefighting?
- A. To detect flammable gases
- B. To separate different compartments for ventilation
- C. To extinguish fires through a fine mist
- D. To protect firefighters from radiant heat
10. When using a fire hose, what is the recommended nozzle pattern for initial cooling of a fire in a confined space?
- A. Straight stream
- B. Cone spray
- C. Fog pattern
- D. Solid stream
11. In advanced firefighting, what is the primary function of a fire axe?
- A. Ventilating smoke from the compartment
- B. Applying foam to the fire
- C. Cutting through bulkheads and doors
- D. Spraying water in a concentrated stream
12. What does the term "fire tetrahedron" refer to in the context of firefighting?
- A. A four-sided firefighting tool
- B. The four elements required for combustion
- C. A specialized firefighting drill
- D. A geometric shape used in fire suppression
13. In the event of an electrical fire onboard, which firefighting equipment is specifically designed for use?
- A. Foam extinguisher
- B. Dry powder extinguisher
- C. Water mist extinguisher
- D. CO2 (Carbon Dioxide) extinguisher
14. What is the purpose of a fireman's outfit (protective clothing) in advanced firefighting?
- A. To store firefighting tools
- B. To enhance physical agility
- C. To provide protection from heat and flame
- D. To identify firefighting personnel
15. In the context of fire safety, what does the acronym "RECAAR" stand for?
- A. Rescue, Evacuation, Containment, Assessment, and Recovery
- B. Rescue, Evacuation, and Containment of Aerial Risks
- C. Response, Escape, and Control Against Adverse Reactions
- D. Rapid Escape and Control Against Radiant heat
16. What is the purpose of a flame arrester in firefighting?
- A. To arrest the progression of flames in a compartment
- B. To control the spread of flammable liquids
- C. To provide visual cues during firefighting operations
- D. To enhance communication among firefighters
17. During a shipboard fire emergency, what is the primary purpose of the muster list?
- A. To account for all personnel and passengers
- B. To allocate firefighting responsibilities
- C. To identify the location of fire hydrants
- D. To provide instructions for firefighting techniques
18. What is the recommended method for handling an injured person during a shipboard firefighting operation?
- A. Immediate evacuation to the shore
- B. Moving the person to a designated safe area
- C. Placing the person in a confined space
- D. Administering first aid at the fire location
19. Which firefighting agent is commonly used to suppress fires involving flammable metals?
- A. Foam
- B. Dry powder
- C. Water
- D. CO2 (Carbon Dioxide)
20. What is the purpose of a fire control plan on a ship?
- A. To provide guidance for controlling and suppressing fires
- B. To outline emergency escape routes for passengers
- C. To specify the locations of fire alarm pull stations
- D. To identify the ship's navigation routes
21. What is the purpose of a deluge system in shipboard firefighting?
- A. To deliver a high-pressure water mist
- B. To control electrical fires with a dry powder
- C. To generate foam for flammable liquid fires
- D. To flood a compartment with water rapidly
22. During a shipboard firefighting operation, what is the primary function of a portable gas detector?
- A. To monitor radio communication
- B. To identify flammable gases
- C. To measure ambient temperature
- D. To locate fire hydrants
23. In the context of advanced firefighting, what is the purpose of a water curtain?
- A. To supply water to firefighting hoses
- B. To create a visual signal for distress
- C. To generate foam for liquid fires
- D. To create a barrier against radiant heat
24. Which firefighting equipment is commonly used to cut ventilation openings in ship compartments?
- A. Water fog nozzle
- B. Hydraulic rescue tool
- C. Fire axe
- D. Thermal imaging camera
25. During a shipboard firefighting operation, what is the primary purpose of a positive pressure breathing apparatus (PPBA)?
- A. To maintain positive pressure inside the mask
- B. To prevent smoke from entering the mask
- C. To supply fresh air to the compartment
- D. To enhance communication among firefighters
26. What is the primary function of the emergency generator automatic starting relay during a main power failure?
- A. Stop the emergency fire pump motor
- B. Open the main engine fuel oil quick closing valve
- C. Discharge fixed CO2 into cargo holds
- D. Automatically start the emergency diesel generator and connect it to the emergency switchboard within 45 seconds
27. What is the mandatory maintenance requirement under SOLAS Chapter II-2 for international shore connections on cargo ships?
- A. Kept readily accessible on deck with a gasket, bolts, and nuts ready for immediate use
- B. Stowed in the chief mate's office
- C. Kept in the paint locker
- D. Stored inside the engine room workshop
28. Regarding deck and engine room operational protocols in Advanced Fire Fighting, what is the mandatory safety standard required under STCW Code Table A-VI/2?
- A. Non-mandatory recommendation
- B. Optional compliance based on crew discretion
- C. Applicable only when vessel is anchored
- D. Full compliance with approved STCW safety procedures and SMS protocols
29. What is the primary function of the emergency fire pump isolation valve located on the main deck?
- A. Divert water to the bilge system
- B. Prevent backflow to the sea chest
- C. Increase water pressure to the bridge
- D. Isolate the engine room fire main from the deck fire main
30. Under SOLAS regulations, what is the minimum water capacity for the emergency fire pump on cargo vessels?
- A. At least 25 m³/h or 40% of required main pump capacity
- B. 10 m³/h fixed rate
- C. 50 m³/h continuous flow
- D. 100 m³/h at maximum RPM
Set 2 — 30 AFF exit exam questions with answers
1. What type of fixed fire extinguishing system is required for paint lockers having a deck area greater than 4 m²?
- A. Inert gas generator
- B. High-expansion foam only
- C. Dry powder system only
- D. Fixed CO2 or water-sprinkling fire extinguishing system
2. What pre-release protocol must be completed before discharging CO2 into an engine room space?
- A. Ensure all personnel are evacuated, ventilation fans stopped, and dampers closed tight
- B. Open skylights to vent pressure
- C. Start emergency generator
- D. Keep exhaust ventilation running at half speed
3. What is the principal extinguishing mechanism of High-Expansion Foam when applied to machinery space bilges?
- A. Absorbing oil spills
- B. Cooling hot steel bulkheads
- C. Rapid volume filling and total smothering of flammable surface vapors
- D. Diluting fuel vapors
4. What is the maximum allowable pressure drop before an SCBA compressed air cylinder must be recharged?
- A. 25% below working pressure
- B. 5 bar drop
- C. 50% below working pressure
- D. 10% below nominal working pressure
5. What is the function of the International Shore Connection fitted on shipboard fire mains?
- A. Discharge oily bilge water to shore
- B. Enable shore fire lines to connect to the vessel's fire main regardless of port hose fittings
- C. Bunker fresh water from shore
- D. Supply shore electrical power
6. What is the primary objective of boundary cooling during a shipboard compartment fire?
- A. Prevent heat transfer through bulkheads and decks to stop fire spread to adjacent spaces
- B. Extinguish the primary fire flame
- C. Cool the firefighting team's turnout suits
- D. Reduce water pressure in the fire main
7. Under SOLAS Chapter II-2, how many firefighter outfits must be carried on cargo ships of 500 GT and above?
- A. At least 6 outfits
- B. At least 2 firefighter outfits
- C. At least 4 outfits
- D. At least 1 outfit
8. What safety precaution is mandatory when entering a compartment after a fixed CO2 system has been discharged?
- A. Wait 5 minutes without testing
- B. Verify complete gas-freeing and atmospheric testing (O2 at 20.9%) using approved sensors
- C. Enter immediately after opening door
- D. Wear a cotton dust mask only
9. What is the purpose of the relief valve fitted on a fire main isolation system?
- A. Drain water during freezing weather
- B. Supply water to deck scuppers
- C. Allow air to vent from the system
- D. Protect fire piping from over-pressurization during emergency pump operation
10. Which SOLAS requirement applies to quick-closing valves on fuel oil tanks in case of engine room fire?
- A. They must be tested every 5 years
- B. They can only be operated manually inside the engine room
- C. They must be capable of being closed from a safe position outside the engine room
- D. They must close automatically at 50 degrees C
11. What is the minimum operating duration required for an approved SCBA cylinder used in firefighting?
- A. At least 30 minutes
- B. 60 minutes
- C. 15 minutes
- D. 45 minutes
12. What type of foam compound is most effective for extinguishing polar solvent alcohol fires on chemical tankers?
- A. Alcohol-Resistant Aqueous Film-Forming Foam (AR-AFFF)
- B. High-Expansion Synthetic Foam
- C. Fluoroprotein Foam
- D. Standard Protein Foam
13. Why must fire hoses be pressure tested annually onboard ships?
- A. To verify structural integrity and prevent hose burst under emergency working pressure
- B. To clean internal salt deposits
- C. To satisfy customs inspections
- D. To measure water flow rate
14. What is the main advantage of a water mist fire extinguishing system compared to traditional sprinkler systems?
- A. Requires no pumps or piping
- B. Fills the space with chemical powder
- C. Requires higher electrical voltage
- D. Uses significantly less water while providing high heat absorption and rapid oxygen displacement
15. Under STCW, what is the role of the On-Scene Commander during a major shipboard fire incident?
- A. Operate the main engine throttle
- B. Maintain passenger headcount in mess room
- C. Direct tactical firefighting operations at the fire scene and communicate with the Command Team
- D. Stay on the bridge to navigate the ship
16. What safety feature prevents accidental discharge of fixed CO2 fire extinguishing systems?
- A. Automatic trigger at 30°C
- B. Double-valve protection with pilot control and alarm trip switches in locked release cabinets
- C. Threaded cap on main discharge pipe
- D. Single push button on the bridge
17. What device must be worn by firefighters in low oxygen or toxic smoke environments?
- A. Dust filter mask
- B. Canister gas mask
- C. Wet handkerchief
- D. Self-Contained Breathing Apparatus (SCBA)
18. How often must emergency fire pumps be tested operational according to SOLAS safety management system routines?
- A. Monthly
- B. Annually
- C. Quarterly
- D. Weekly
19. What is the correct procedure for searching a smoke-filled compartment during search and rescue?
- A. Crawl along ceiling piping
- B. Run to the far corner immediately
- C. Maintain continuous physical or wall contact and sweep floor area systematically
- D. Walk upright quickly with flashlight
20. What is the primary function of drenching systems fitted on roll-on/roll-off (Ro-Ro) vehicle decks?
- A. Provide rapid total-area water coverage to extinguish vehicle fires quickly
- B. Cool exhaust manifolds
- C. Wash down vehicle tires
- D. Provide fresh drinking water
21. Which class of fire involves energized electrical equipment such as switchboards or electric motors?
- A. Class B
- B. Class A
- C. Class C (or Electrical Fire)
- D. Class D
22. Why must firefighter turnout gear be thoroughly cleaned after exposure to heavy smoke?
- A. To increase thermal weight
- B. To remove carcinogenic combustion products and flammable chemical residues
- C. To restore shiny color
- D. To shrink the material tight
23. What is the purpose of a flame arrestor fitted on a fuel tank vent pipe?
- A. Regulate fuel pumping speed
- B. Prevent external flames from traveling into the fuel vapor space
- C. Stop fuel overflow
- D. Filter air dust
24. What is the minimum number of spare SCBA air charges required onboard cargo ships?
- A. None required if compressor available
- B. 5 spare charges per set
- C. At least 2 spare charges per required SCBA set
- D. 1 spare charge total
25. A safety is provided on the CO2 discharge piping to prevent:
- A. Rupture of cylinder due to temperature increase
- B. Over pressurization of the space being flooded
- C. Flooding of a space where personnel are present
- D. Over pressurization of the CO2 discharge piping
26. Apart from red what other color is frequently used for a CO2 extinguisher:
- A. Yellow
- B. Blue
- C. Black
- D. Red
27. In fighting a fire in a fuel tank, the first action you should attempt is to:
- A. Station someone at the fixed CO2 release controls
- B. Begin transferring the fuel to other tanks
- C. Top off the tank to force out all vapors
- D. Secure all sources of fresh air to the tank
28. The FIRST course of action in fighting a fire in a cargo or fuel oil tank is to:
- A. Direct a fire hose into the tank and energize the fire main
- B. Spray the tank boundaries with a fire hose to promote cooling
- C. Discharge an initial charge of CO2 with a hand portable extinguisher
- D. Secure all openings to the tank
29. Three side of fire triangle are fuel, heat and ............?
- A. Oxygen
- B. Petrol
- C. Gases
- D. Combustible material
30. In a fixed CO2 fire extinguishing system where pressure from pilot cylinders is used to release the CO2 from the main bank of cylinders, the number of required pilot cylinders shall be at least:
- A. 4
- B. 3
- C. 2
- D. 6
Set 3 — 30 AFF exit exam questions with answers
1. Fixed CO2 systems would not be used on crew's quarters or:
- A. the engine room
- B. spaces open to the atmosphere
- C. cargo holds
- D. the paint locker
2. Your vessel is equipped with a fixed CO2 system and a fire main system. In the event of an electrical fire in the engine room what is the correct procedure for fighting the fire?
- A. Evacuate the engine room and use the fire main system.
- B. Use the CO2 system and evacuate the engine room.
- C. Use the fire main system and evacuate the engine room.
- D. Evacuate the engine room and use the CO2 system.
3. When pilot cylinder pressure is used as a means to release the CO2 from a fixed fire extinguishing system consisting of four storage cylinders, the number of pilot cylinders shall be at least:
- A. 3
- B. 1
- C. 4
- D. 2
4. After extinguishing a paint locker fire using the fixed CO2 system, the next action is to have the space:
- A. doused with water to prevent reflash
- B. left closed with vents off until all boundaries are cool
- C. opened and burned material removed
- D. checked for oxygen content
5. In a fixed CO2 extinguishing system where provision is made for the release of CO2 by operation of a remote control, provision shall also be made for releasing the CO2:
- A. from inside the engine room
- B. from the bridge
- C. at the cylinder location
- D. from the cargo control station
6. Which of the following statements is FALSE, concerning the regulations pertaining to the cylinder room of a fixed CO2 fire extinguishing system?
- A. The door must be kept unlocked.
- B. The compartment shall be clearly marked and identifiable.
- C. The temperature of the room should never exceed 130°F.
- D. The compartment must be properly ventilated.
7. You are releasing carbon dioxide gas (CO2) into an engine compartment to extinguish a fire. The CO2 will be most effective if the:
- A. compartment is closed and ventilators are opened
- B. air flow to the compartment is increased with blowers
- C. compartment is closed and airtight
- D. compartment is left open to the air
8. CO2 cylinders, which protect the small space in which they are stored must:
- A. have an audible alarm
- B. All of the above
- C. be automatically operated by a heat actuator
- D. NOT contain more than 200 pounds of CO2
9. In areas where CO2 piping is installed, such piping may not be used for any other purpose EXCEPT:
- A. to run the emergency wiring to the space
- B. in connection with the fire-detecting system
- C. in connection with the water sprinkler system
- D. to ventilate the space
10. Control valves of a CO2 system may be located within the protected space when:
- A. it is impractical to locate them outside
- B. an automatic heat-sensing trip is installed
- C. the CO2 cylinders are also in the space
- D. there is also a control valve outside
11. While you are working in a space, the fixed CO2 system is accidentally activated. You should:
- A. continue with your work as there is nothing you can do to stop the flow of CO2
- B. secure the applicators to preserve the charge in the cylinders
- C. retreat to fresh air and ventilate the compartment before returning
- D. make sure all doors and vents are secured
12. Large volumes of carbon dioxide are safe and effective for fighting fires in enclosed spaces, such as in a pumproom, provided that the:
- A. ventilation system is secured and all persons leave the space
- B. persons in the space wear damp cloths over their mouths and nostrils
- C. ventilation system is kept operating
- D. persons in the space wear gas masks
13. Automatic mechanical ventilation shutdown is required for CO2 systems protecting the:
- A. living quarters
- B. galley
- C. machinery spaces
- D. cargo compartments
14. Carbon dioxide as a fire fighting agent has which advantage over other agents?
- A. It causes minimal damage.
- B. It is most effective on a per unit basis.
- C. It is safer for personnel.
- D. It is cheaper.
15. CO2 cylinders forming part of a fixed fire extinguishing system must be pressure tested at least every:
- A. 2 years
- B. 12 years
- C. year
- D. 6 years
16. Fixed carbon dioxide extinguishing systems, for machinery spaces that are normally manned, are actuated by one control to open the stop valve in the line leading to the space, and:
- A. separate control to release the CO2
- B. three separate controls to release the CO2
- C. two separate controls to release the CO2
- D. the same control releasing the CO2
17. A fixed carbon dioxide extinguishing system for a machinery space, designed WITHOUT a stop valve in the line leading to the protected space, is actuated by:
- A. three controls
- B. one control
- C. none of the above
- D. two controls
18. On cargo vessels, the discharge of the required quantity of carbon dioxide into any 'tight' space shall be completed within:
- A. 6 minutes
- B. 4 minutes
- C. 2 minutes
- D. 1 minute
19. Aboard a cargo vessel, the supply of carbon dioxide used in a fixed extinguishing system MUST at least be sufficient for what space:
- A. all cargo spaces
- B. the space requiring the largest amount
- C. the engine room and largest cargo space
- D. all the spaces of a vessel
20. How often must CO2 systems be inspected to confirm cylinders are within 10% of the stamped full weight of the charge:
- A. quarterly
- B. biannually
- C. annually
- D. semiannually
21. In weighing CO2 cylinders, they must be recharged if weight loss exceeds:
- A. 10% of weight of full bottle
- B. 10% of weight of charge
- C. 15% of weight of full bottle
- D. 20% of weight of charge
22. Before using a fixed CO2 system to fight an engine room fire, you must:
- A. secure the machinery in the engine room
- B. All of the above
- C. secure the engine room ventilation
- D. evacuate all engine room personnel
23. The CO2 flooding system is actuated by a sequence of steps which are:
- A. break glass, pull valve, break glass, pull cylinder control
- B. open stop valve, open control valve, trip alarm
- C. sound evacuation alarm, pull handle
- D. open bypass valve, break glass, pull handle
24. Which advantage does dry chemical have over carbon dioxide (CO2) in firefighting?
- A. More protective against re-flash
- B. Compatible with all foam agents
- C. Cleaner
- D. All of the above
25. What is NOT a characteristic of carbon dioxide fire-extinguishing agents?
- A. Will not deteriorate in storage
- B. Effective even if ventilation is not shut down
- C. Effective on electrical equipment
- D. Non-corrosive
26. In a fixed carbon dioxide extinguishing system for a machinery space, designed WITH a stop valve in the line leading to the protected space, the flow of CO2 is established by actuating:
- A. two controls
- B. one control
- C. none of the above
- D. three controls
27. An important step in fighting any electrical fire is to:
- A. Increase ventilation
- B. De-energize the circuit
- C. Use chemical foam
- D. Apply water fog immediately
28. Which fire detection system is actuated by sensing a heat rise in a compartment?
- A. Flame detection system
- B. Automatic fire detection system
- C. Manual pull stations
- D. Smoke obstruction system
29. Water fog is an effective firefighting agent because it:
- A. Has a great cooling ability
- B. Breaks the molecular chain reaction chemically
- C. Smothers the fire using dense foam
- D. Displaces oxygen completely
30. A fire of escaping liquefied flammable gas is best extinguished by:
- A. Cooling the surrounding storage cylinders
- B. Applying large amounts of dry chemical powder
- C. Flooding with low-velocity fog
- D. Stopping the flow of gas
Set 4 — 30 AFF exit exam questions with answers
1. When combating a Class C fire, which of the following dangers may be present?
- A. Exploding fuel-air vapor mixtures
- B. Toxic fumes from burning insulation or electric shock
- C. High expansion foam flashover
- D. Spontaneous combustion of scrap metal
2. The lowest temperature at which the vapors of a flammable liquid will ignite and cause self-sustained combustion in the presence of a spark or flame is the:
- A. Flash Point
- B. Critical Point
- C. Ignition Point
- D. Fire Point
3. The fire protection provided for the propulsion motor and generator of a diesel-electric drive vessel is usually a:
- A. Dry powder station
- B. Fixed CO2 system
- C. Water sprinkler system
- D. Fixed foam system
4. Metal fires should be fought using which extinguisher type?
- A. Halon gas
- B. Carbon dioxide
- C. Aqueous film-forming foam (AFFF)
- D. Dry powder
5. Which type of portable fire extinguisher is best suited for putting out a Class D fire?
- A. Carbon dioxide
- B. Dry powder
- C. Dry chemical
- D. Water spray
6. Class 1 watertight doors are:
- A. Rolling type
- B. Hinged type
- C. Vertical sliding type
- D. Horizontal sliding type
7. A fire in a fuel oil settling tank is a:
- A. Class A fire
- B. Class C fire
- C. Class B fire
- D. Class D fire
8. The symbols for Fire Control plans are approved by which organization?
- A. International Labor Organization (ILO)
- B. International Maritime Organization (IMO)
- C. International Standards Organization (ISO)
- D. National Fire Protection Association (NFPA)
9. Which dangerous condition should be kept in mind after using a 6.8 kg CO2 fire extinguisher on a small oil fire on the engine room floor plates?
- A. Suffocation inside the main casing
- B. Rupture of downstream valves
- C. Rekindling of the fire
- D. Freezing of mechanical controls
10. What emergency equipment is NOT found in the crew mess in the view of a Fire Control plan?
- A. Portable fire extinguisher
- B. Heat sensor
- C. Emergency escape breathing device (EEBD)
- D. Fire axe
11. Dry powder fire extinguishers which contain a mixture of graphite and sodium chloride as firefighting agents are generally used to fight which type of fire?
- A. Class C electrical fire
- B. Class B fuel oil fire
- C. Class D metal fire
- D. Class A wood fire
12. On international voyages, tank ships of 500 gross tons or more are required to have facilities to enable connection on each side of the ship for this fire control equipment:
- A. Emergency bilge pump suction manifold
- B. Fixed sprinkler bypass valve
- C. High expansion foam generator
- D. International Shore connection
13. Mechanical foam used for firefighting is produced by mechanically mixing and agitating:
- A. Dry chemical powder with water stream
- B. Foam chemical with nitrogen gas
- C. Liquid CO2 with water solution
- D. Foam chemical with air and water
14. What must be mounted at a small passenger vessel's operating station for use by the master and crew?
- A. SOLAS training booklet
- B. International code of signals chart
- C. Vessel maintenance record
- D. Emergency instructions
15. The muster list shows each rig hand's muster station, his duties during abandonment, basic instructions, and:
- A. Engine room operating instructions
- B. All emergency signals
- C. Next port of call logistics
- D. Navigation course parameters
16. If a fire ignites in the engine room as a result of a high-pressure fuel oil leak, you should first:
- A. Direct a stream of water at the flames
- B. Shut off the fuel oil supply
- C. Evacuate all personnel immediately
- D. Release the fixed CO2 system
17. If there has been a fire in a closed, unventilated compartment, it may be unsafe to enter because of:
- A. High accumulations of nitrogen gas
- B. Excess relative humidity
- C. lack of oxygen
- D. Built-up electrostatic charges
18. Which of the listed classes of fires can best be extinguished with a water fog?
- A. Class B and C
- B. Class A and B
- C. Class A and D
- D. Class C and D
19. The fixed CO2 fire extinguishing system has been activated to extinguish a large engine room bilge fire. When is the best time to vent the combustible products from the engine room?
- A. Right before entering the space with an SCBA
- B. One hour after initial discharge regardless of temperature
- C. After the metal surfaces have cooled down
- D. Immediately after the fire goes out
20. A definite advantage of using water as a firefighting agent is its characteristic of:
- A. Leaving clean residue that acts as a fire barrier
- B. Rapid expansion as water absorbs heat and changes to steam
- C. Breaking down chemical bonding chains safely
- D. Non-conductivity near live machinery
21. What is NOT a characteristic of a carbon dioxide fire extinguishing agent?
- A. It leaves no messy residue after use
- B. It displaces air to smother a fire
- C. It is effective even if ventilation is not shut down
- D. It can cause frostbite upon contact with skin
22. It is necessary to secure the forced ventilation to a compartment where there is a fire to:
- A. Retain toxic gases to help smother flames
- B. Prevent additional oxygen from reaching the fire
- C. Limit the expansion of cooling steam lines
- D. Protect the ventilation fan motor from overspeeding
23. The four basic components of a fire are a chain reaction, heat, fuel, and:
- A. Nitrogen
- B. Carbon dioxide
- C. Oxygen
- D. Carbon monoxide
24. The flammable limits of an atmosphere are the:
- A. Upper and lower percentage of vapor concentrations in an atmosphere which will burn if an ignition source is present
- B. Maximum temperatures at which an oil source produces vapors
- C. Minimum moisture concentrations needed to halt spontaneous ignition
- D. Safe ambient operating thresholds for storage facilities
25. A fire must be ventilated:
- A. To cool down fuel reservoirs below their flashpoints
- B. To supply additional oxygen to speed up burning
- C. To prevent the gases of combustion from surrounding the firefighters
- D. Immediately after triggering a fixed gas smothering system
26. A fire in a radio transmitter would be of what class under NFPA?
- A. Class B
- B. Class D
- C. Class C
- D. Class A
27. Containers are manufactured as per standards set by:
- A. SOLAS
- B. ISO
- C. MARPOL
- D. IMO
28. What, when removed, will assist in the self-extinguishment of a fire?
- A. Argon
- B. Carbon dioxide
- C. Oxygen
- D. Nitrogen
29. Classification of fire bulkheads inside accommodation spaces is based on fire resisting capabilities. They are classified as:
- A. Class X, Y, Z
- B. Class H, J, K
- C. Class 1, 2, 3
- D. Class A, B, C
30. Good housekeeping on a vessel prevents fire by:
- A. Eliminating potential fuel sources
- B. Cooling electrical control systems
- C. Improving the speed of bilge pumps
- D. Increasing structural fire boundaries
Set 5 — 30 AFF exit exam questions with answers
1. "Below lower flammable limit" means:
- A. The vapor mixture is highly volatile and ready to explode
- B. There is insufficient structural oxygen available for combustion
- C. It is a mixture of hydrocarbon gases which is not sufficient to initiate a fire (too lean)
- D. The atmosphere is completely saturated with fuel vapors (too rich)
2. The oxidation process creates:
- A. Free radical inhibitors
- B. Heavy scale deposits
- C. Heat
- D. Cooling vapors
3. An important tool for fire prevention is:
- A. Increasing high-expansion foam reserves
- B. Periodic paint applications
- C. Cleaning and good housekeeping
- D. Keeping internal ventilation doors wide open
4. The tendency or ability of a liquid to vaporize is called:
- A. Viscosity
- B. Capillarity
- C. Density
- D. Volatility
5. A person may operate an air compressor in which of the following areas on board a tank barge?
- A. Generator room
- B. Inside a cargo tank hatch
- C. Pumproom space
- D. Open deck near vapor manifold lines
6. The most efficient way of transferring heat in liquids and gases is called:
- A. Convection
- B. Radiation
- C. Insulation
- D. Conduction
7. Fire and lifeboat stations are required to be listed on the:
- A. Cargo manifest layout
- B. Master list (station bill)
- C. Logbook register
- D. Crew contract binder
8. You can find the location of your abandon ship post by checking the:
- A. Deck logbook entries
- B. Bridge passage plan
- C. Master list
- D. Safety equipment certificate booklet
9. In order to achieve the fire safety objective, which of the following functional requirements are embodied in SOLAS regulations?
- A. All of the above
- B. Division of the ship into main horizontal/vertical zones by thermal and structural boundaries
- C. Separation of accommodation spaces from the remainder of the ship by thermal and structural boundaries
- D. Protective means of escape and access for firefighting
10. The vessel's Fire Control plan is laid out on which of the following types of plan?
- A. General arrangement
- B. Midship structural section
- C. Lines plan drawing
- D. Tank capacity schematic
11. Carbon dioxide is stored under pressure in liquid form inside a fire:
- A. Cylinder
- B. Storage box enclosure
- C. Hose connection reel
- D. Foam applicator drum
12. Which statement concerning carbon dioxide is FALSE?
- A. It extinguishes fire by smothering action
- B. It is safe to use near personnel in a confined space
- C. It leaves no dynamic residue on machinery components
- D. It can be utilized safely on electrical fires
13. Which class division is considered capable of preventing the passage of ONLY flame to the end of the first half-hour of a standard fire test?
- A. Class B
- B. Class D
- C. Class A
- D. Class C
14. A fire hose can be used for purposes other than firefighting service when:
- A. Clearing choked scupper valves
- B. Washing down cargo decks at sea
- C. Used for drills and testing
- D. Supplying cooling fluid to a temporary generator
15. How many CO2 fire extinguishers ought to be kept in accommodation areas?
- A. Four on each deck landing
- B. Two near the galley spaces
- C. No extinguishers
- D. One per room corridor
16. Portable foam fire extinguishers are designed for use on which classes of fires?
- A. Class A and D fires
- B. Class A and B fires
- C. Class B and C fires
- D. Class C and D fires
17. The removal of fuel in the firefighting process is known as:
- A. Inhibition
- B. Starvation
- C. Smothering
- D. Cooling
18. Why is a CO2 type of fire extinguisher preferred for electrical installations?
- A. It expands into a sticky visual foam barrier
- B. It provides extensive long-term cooling
- C. It can be safely deployed without isolating power circuits
- D. It leaves no residue and does not damage any equipment
19. Which of the listed extinguishing agents is NOT suitable for fighting a liquid paint fire?
- A. Mechanical foam spray
- B. Dry chemical powder
- C. Carbon dioxide gas
- D. Water
20. As per NFPA (National Fire Protection Association), a fire in cooking appliances involving vegetable/animal oils and fats is classified as:
- A. Class K
- B. Class C
- C. Class D
- D. Class B
21. Designated areas for smoking are specified in the:
- A. Company manual
- B. Crew mess instruction card
- C. Port state entry document
- D. International code manual
22. The spreading of fire as a result of heat being carried through a vessel's ventilation system is an example of heat transfer by:
- A. Convection
- B. Conduction
- C. Absorption
- D. Radiation
23. On cargo and miscellaneous vessels, what is NOT a required part of the fireman's outfit?
- A. Rigid boots and gloves
- B. Protective clothing
- C. Combustible gas indicator
- D. Flame safety lamp or breathing apparatus
24. A fire hose kept in its box should have a wrench and an:
- A. High expansion foam generator tube
- B. All-purpose nozzle
- C. High-pressure mechanical lance tool
- D. International Shore standard coupling flange
25. Actuating the fixed CO2 system should cause the automatic shutdown of the:
- A. Main switchboard power grid distribution
- B. Emergency bilge pump circuits
- C. Supply and exhaust ventilation
- D. Main engine propulsion controls
26. During a fire onboard, communication is to be:
- A. Relayed solely via messengers
- B. Complex, thoroughly detailed, and extensive
- C. Concise, precise, and short
- D. Postponed until structural assessments end
27. A solid stream of water is produced by an all-purpose firefighting nozzle when the handle is:
- A. Pulled all the way back
- B. Pushed all the way forward
- C. Twisted ninety degrees counterclockwise
- D. Positioned halfway into its casing
28. Immediately after extinguishing a fire with CO2, it is advisable to:
- A. Drain internal oil recovery sumps directly
- B. Restore structural compartment ventilation fully
- C. Open up all access ports to inspect inside details
- D. Stand by with water or other agents
29. Ships carrying more than 36 passengers should maintain a:
- A. Double bulkhead smoke containment grid
- B. Dedicated fire drill barge trailer connection
- C. Continuous automated water system monitor
- D. Fire patrol system
30. During cargo operations, a deck fire has occurred due to a leaking cargo line. You should first:
- A. Douse structural pipelines with sea spray
- B. Stop the transfer of cargo
- C. Sound the international collision alarm whistle
- D. Rig a mechanical foam generator station
Set 6 — 30 AFF exit exam questions with answers
1. Radio station logs involving communication during a disaster shall be kept by the station licensee for at least:
- A. Ten years inside safe archive storage boxes
- B. Three years from the date of the last entry
- C. One year from entry initiation
- D. Five years under legal maritime seals
2. The deep fryer oil overheated because of a:
- A. Lack of fresh liquid fat inputs
- B. Thermostat malfunctioning
- C. Blockage inside draining pipe lines
- D. Mechanical failure inside the extractor canopy
3. The best way to test the Inmarsat-C terminal is to:
- A. Sound the internal automatic distress loop button
- B. Place a voice phone link call to shore coordination networks
- C. Compose and send a brief message to your own Inmarsat-C terminal
- D. Contact an adjacent vessel via bridge VHF radio link
4. The control panel of a fire detection system must have all of the following EXCEPT:
- A. way to bypass the entire panel if it malfunctions
- B. Test switches to check structural loop indicators
- C. Visual indicators showing alarm sectors
- D. An audible device to signal alarms or system faults
5. Tapioca is susceptible to ________ when damp.
- A. Chemical crystallization
- B. Electrostatic discharges
- C. Liquefaction slide effects
- D. Spontaneous combustion
6. As a firefighting medium, CO2 can be dangerous under certain conditions as it can cause:
- A. Severe toxic vapor contamination inside boiler loops
- B. Freeze burns and blistering
- C. Spontaneous flashover due to compression waves
- D. Corrosion of sensitive mechanical gears
7. As per NFPA, a fire in an electrical generator is considered to be a:
- A. Class C fire
- B. Class D fire
- C. Class B fire
- D. Class A fire
8. If passengers are on board when an abandon ship drill is carried out, they should:
- A. Remain inside their cabins behind closed safety doors
- B. Be evacuated on an auxiliary service tender craft
- C. Gather exclusively at public dining lounges
- D. Take part
9. On the vessel's Fire Control plan, all parts of a fixed fire suppression system are listed EXCEPT:
- A. Instructions for activation of the system
- B. Total weight and type of chemical storage canisters
- C. Location of piping distribution loops
- D. Placement of discharge nozzles across compartments
10. Through which of the listed processes is sufficient heat produced to cause spontaneous ignition?
- A. Heat of condensation
- B. Heat of vaporization
- C. Heat of radiation
- D. Heat of oxidation
11. Fusible link fire dampers are operated by:
- A. Electronic loop control commands from the safety desk
- B. Hydrostatic water pressure changes from water spray systems
- C. The heat of the fire melting the link
- D. Structural balance wires linked with the bridge desk
12. You have just extinguished an oil fire on the floor plates of the engine room with a 15-pound CO2 extinguisher. Which of the listed dangers should you now be preparing to handle?
- A. Frostbite cracks inside fuel line connection joints
- B. Reflashing of the fire
- C. Complete systemic failure of main engine gear oil feeds
- D. Toxic gas ignition inside air trunk lines
13. The height of a VHF radio antenna is more important than the power output wattage of the radio because:
- A. Skywave atmospheric returns are highly unstable at sea
- B. Internal wire resistances limit low-level signal paths
- C. Higher placement reduces tracking ground interference loops
- D. VHF communications are basically line of sight
14. Which extinguishing agent is most likely to allow reflash as a result of not cooling the fuel below its ignition temperature?
- A. Aqueous film-forming foam (AFFF)
- B. Dry chemical powder mix
- C. CO2
- D. Water fog stream
15. A vessel's Fire Control plan shall have:
- A. duplicate set of plans permanently stored outside the deck house in a prominent weatherproof enclosure
- B. Blueprint files locked exclusively in the captain's office
- C. Plastic layout cards stapled on every accommodation deck door
- D. Microfiche summary records mounted inside all lifeboats
16. In the regulations for cargo vessels, which statement is true concerning a fireman's outfit?
- A. Each fireman's outfit shall contain a flame safety lamp of an approved type
- B. Two outfits are needed for each active deck crewman
- C. Each outfit must contain an electric welding cutting tool
- D. Air tanks must carry five hours of continuous storage reserves
17. Fire alarm system thermostats are actuated by:
- A. Light scattering effects across laser sensors
- B. Air pressure changes inside trunk compartments
- C. Moisture tracking limits inside structural wiring panels
- D. The difference in thermal expansion of two dissimilar metals
18. For the safety of the personnel working with fire hoses, the fire pumps are fitted with a:
- A. Pressure gauge and relief valve on the discharge side
- B. Flexible expansion joint directly on the water suction intake
- C. Mechanical safety clutch linkage on driving engines
- D. Remote automated vacuum seal breaker
19. Dry chemical extinguishers extinguish Class B fires to the greatest extent by:
- A. Breaking the chain reaction
- B. Cooling fuel temperatures down below flashpoint margins
- C. Freezing burning vapor pools immediately
- D. Displacing essential atmospheric nitrogen compounds
20. What shall be conducted during a fire and boat drill?
- A. All watertight doors in the vicinity of the drill shall be operated
- B. Lifeboats must be launched and run at service speeds for an hour
- C. Emergency bilge suctions must be run on full backflow parameters
- D. Cargo tank hatches must be opened for visual gas checking
21. When approaching a fire from windward, you should shield firefighters from the fire by using an applicator and:
- A. High expansion foam blanket throw
- B. CO2 continuous vapor jet
- C. Low velocity fog
- D. High velocity solid water jet
22. The extinguishing agent most likely to allow re-ignition of a fire is:
- A. Water fog
- B. Mechanical foam spray
- C. Carbon dioxide
- D. Dry chemical powder
23. The risk of fire and explosion is ________ in tankers.
- A. Identical to generic dry cargo vessels
- B. Controlled solely by hull thickness layout
- C. Negligible under standard cruising speeds
- D. Very high
24. Why should foam be banked off a bulkhead when extinguishing an oil fire?
- A. To prevent agitation of the oil and spreading the fire
- B. To speed up chemical stabilization loops of active foam bubbles
- C. To avoid cooling structural steel components unevenly
- D. To maximize the coverage range of standard delivery equipment
25. A large oil fire on the deck of a ship can be fought most effectively with:
- A. Solid streams of sea water
- B. High pressure carbon dioxide gas grids
- C. Foam
- D. Portable dry powder spray canisters
26. The minimum flashpoint of oil fuel carried on board a ship is:
- A. 50 degrees Celsius
- B. 70 degrees Celsius
- C. 60 degrees Celsius
- D. 40 degrees Celsius
27. You are operating a fire hose with an applicator attached. If you put the handle of the nozzle in the vertical position, you will use:
- A. High velocity solid jet stream
- B. Shutoff position with zero output flow
- C. Foam solution delivery parameter
- D. Low velocity fog
28. To safely enter a compartment where CO2 has been released from a fixed extinguishing system, you should:
- A. Run a hand-held exhaust blower for five minutes first
- B. Wear a self-contained breathing apparatus (SCBA)
- C. Wear a generic particulate dust filter mask
- D. Wait ten minutes for gas settlement before walking in
29. The international shore connection:
- A. Allows hookup of firefighting water from shore facilities
- B. Links ship navigation logs with port administration grids
- C. Supplies high voltage electrical power to propulsion links
- D. Drains oily bilge slops safely to dockside collection tanks
30. A fire has broken out on the stern of your vessel. You should maneuver your vessel so the wind:
- A. Blows at right angles to cross-vent the hull decks
- B. Comes directly over the stern layout beam
- C. Comes over the bow
- D. Changes into circular thermal swirling patterns
Set 7 — 30 AFF exit exam questions with answers
1. An extinguishing agent which effectively cools, dilutes combustible vapors, removes oxygen, and provides a heat and smoke screen is:
- A. Water fog
- B. Halon gas
- C. Dry chemical powder formulation
- D. Aqueous film-forming foam solution
2. The expansion of LFL is:
- A. Light Flame Location
- B. Liquid Fuel Line
- C. Lower Flammable Limit
- D. Low Flashpoint Liquid
3. Which statement describes the primary process by which fires are extinguished by dry chemical?
- A. The active agent drops fuel core parameters past absolute freezing margins
- B. The dry chemical creates a dense visual foam overlay block
- C. It relies on heavy moisture transformation into structural vapor screens
- D. The dry chemical powder attacks the fuel and oxygen chain reaction
4. What is the most important consideration when determining to fight an electrical fire?
- A. Danger of shock to personnel
- B. Shutting down auxiliary lighting networks across accommodation spaces
- C. The replacement costs of burnt circuitry components
- D. The clean-up time required for active extinguishing residue
5. If you see an oil leakage, you clean it immediately. This is an example of:
- A. Good housekeeping
- B. ISO structural standard declaration rules
- C. Deck log monitoring instructions
- D. Preventive machinery tuning parameters
6. When dry chemical extinguishers are used to put out Class B fires, there is a danger of reflash because dry chemical:
- A. Reacts aggressively with marine steel materials
- B. Vaporizes into flammable gas compounds under heat exposure
- C. Does little or no cooling
- D. Displaces air structures for only a few seconds
7. Which of the following fire extinguishing agents has the greatest capacity for heat absorption?
- A. Carbon dioxide gas jet
- B. Dry chemical powder spray
- C. Mechanical foam blanket expansion
- D. Water fog
8. The expansion of IBC code is:
- A. International Bilge Control code
- B. International Bulk Cargo code
- C. International Bulk Chemical code
- D. Intermaritime Boiler Construction code
9. As compared to carbon dioxide, dry chemical has which advantage?
- A. Greater range
- B. It is non-toxic inside confined spaces
- C. It offers significant localized thermal cooling effects
- D. It leaves no visible residue cleanup footprint on components
10. Which of the listed firefighting agents and associated applications provide the largest shielding effect for the firefighter?
- A. Continuous carbon dioxide stream jet
- B. Low velocity water fog
- C. Straight high-velocity water jet
- D. High-expansion chemical foam spray
11. An example of a type of smoke detector is the:
- A. Visual infrared flame scanner screen
- B. Ionization type
- C. Hydrostatic expansion capsule sensor
- D. Thermal differential bimetallic link switch
12. Which firefighting agent is most effective in removing heat?
- A. Carbon dioxide vapor stream
- B. Dry chemical powder blanket throw
- C. Mechanical structural foam solution
- D. Water spray
13. When water fog is used as an extinguishing agent, the fire is extinguished principally by the:
- A. Displacement of active fuel structures safely
- B. Exclusion of atmospheric nitrogen elements
- C. Chemical breakdown of active free radicals
- D. Absorption of heat
14. Fire extinguishers of sizes 3, 4, and 5 are designated as:
- A. Hand portable
- B. Semi-portable
- C. Fixed system bank units
- D. Auxiliary utility modules
15. Dangerous goods are classified into how many groups?
- A. Three groups
- B. Five groups
- C. Twelve groups
- D. Nine groups
16. The discharge from a carbon dioxide fire extinguisher should be directed:
- A. At the top perimeter layout of smoke clouds
- B. Directly into adjacent ventilation return trunks
- C. At the base of the flames
- D. In wide looping circles across structural partition bulkheads
17. Which statement is true concerning the use of dry chemical extinguishers?
- A. You should direct the spray at the base of the fire
- B. They are deployed safely on metal fires like sodium or magnesium
- C. You should direct the spray at the top edges of structural smoke screens
- D. They provide deep cooling to prevent any risk of re-ignition
18. What is the minimum number of portable fire extinguishers that must be carried on ships of 1000 GRT and above?
- A. Eight
- B. Three
- C. Five
- D. Two
19. What is the primary function of the emergency fire pump isolate valve fitted on main deck?
- A. Prevent backflow to sea chest
- B. Divert water to bilges
- C. Isolate engine room fire main from deck fire main
- D. Increase fire water pressure to accommodation
20. Under SOLAS, what is the minimum duration for SCBA cylinder duration calculation margin?
- A. 45 minutes at standard atmosphere
- B. 15 minutes at 20 L/min breathing rate
- C. 60 minutes continuous flow
- D. 30 minutes at 40 L/min breathing rate
21. What type of fixed fire extinguishing system is mandatory for paint lockers exceeding specified floor area?
- A. Fixed CO2 or water-sprinkling system
- B. Dry powder system
- C. High expansion foam only
- D. Inert gas generator
22. What action must be taken regarding mechanical ventilation before releasing CO2 into engine room?
- A. Open skylights for pressure relief
- B. Keep exhaust fans running to remove smoke
- C. Stop all fans and close all dampers tight
- D. Set ventilation to 50% capacity
23. What is the main advantage of High-Expansion Foam in engine room bilges?
- A. Rapidly fills volume and smothers fire without liquid weight accumulation
- B. Cools hot steel faster than water jet
- C. Conducts electricity safely
- D. Absorbs oil completely
24. How often must fixed CO2 cylinder weight/pressure checks be conducted on ships?
- A. Annually by certified technician or competent officer
- B. Monthly by chief officer
- C. Every 2 years
- D. Every 5 years during drydock
25. What is the International Shore Connection used for?
- A. Shore electrical power supply
- B. Connecting shore fire water supply to ship fire main
- C. Bunkering fuel from shore
- D. Discharging bilges to shore
26. What is boundary cooling in shipboard firefighting?
- A. Cooling sea chest strainers
- B. Cooling adjacent bulkheads and decks to prevent heat transfer and fire spread
- C. Cooling the fire hose nozzle
- D. Cooling the SCBA wearer with water spray
27. Which nozzle spray setting is recommended when advancing on an interior cabin fire?
- A. Shut off until inside cabin
- B. Wide fog spray at maximum pressure
- C. Solid jet stream directly at ceiling
- D. Narrow fog spray for protection and heat absorption
28. What safety mechanism prevents accidental discharge of a fixed CO2 total flooding system?
- A. Breakable glass seal on main manifold
- B. Hydraulic interlock from bridge
- C. Master key held only by Captain
- D. Two-step control valve box with alarm microswitches
29. Emergency response services to a security incident do not include:
- A. Police
- B. Military
- C. RSO
- D. Fire services
30. What is auto-ignition?
- A. The ignition of a combustible material without initiation by a spark or flame, when the material has been raised to a temperature at which self-sustaining combustion occurs
- B. Automatic ignition of material in a hot atmosphere
- C. Ignition of materials when they come in contact with each other
- D. Ignition caused by a mixture of vapours given off by cargoes
Set 8 — 30 AFF exit exam questions with answers
1. On the all-purpose nozzle, the position of the valve when the handle is all the way forward is ____.
- A. Fog
- B. Spray
- C. Solid stream
- D. Shut
2. Fire is a process of combustion accompanied by the rapid release of heat and ____ in varying intensities.
- A. Light
- B. Energy
- C. Destruction
- D. None of the above
3. Recharging a previously used cartridge-operated dry chemical fire extinguisher is accomplished by ____.
- A. Authorized fire equipment servicing personnel only
- B. Replacing the propellant cartridge and refilling it with powder
- C. Puncturing the cartridge seal after installation
- D. Recharging the cartridge and refilling it with powder
4. What is the minimum capacity of each required fire pump on a cargo ship?
- A. 20 m3/h
- B. 25 m3/h
- C. 30 m3/h
- D. 40 m3/h
5. In which language must the fire control plan on board be written?
- A. Only in the language of the flag State
- B. In the language of the Administration, with a translation into English or French if that language is neither
- C. In any language understood by the master
- D. Only in the working language of the crew
6. When a ship's low-pressure CO2 fixed fire-extinguishing system is activated from a remote location, what determines the quantity of CO2 being released into a selected space?
- A. The number of discharge nozzles in the space
- B. The discharge continues until the temperature of the space returns to normal ambient temperature
- C. The main CO2 tank is partitioned into sections individually designated for each protected space
- D. A pneumatic timer controls each discharge selector valve and is preset for each space
7. Fires which occur in energized electrical equipment, such as switchboard insulation, are class ____.
- A. A
- B. B
- C. C
- D. D
8. Immediately after a class B fire has been extinguished by the use of foam, crew members should ____.
- A. Carefully apply a low-velocity fog over the foam blanket
- B. Wade through the foam blanket to evenly distribute the foam
- C. Be careful not to disturb the foam blanket
- D. Sweep the foam blanket overboard and secure firefighting equipment
9. The advantage of using a dry chemical fire-extinguishing agent is ____.
- A. Permanent extinguishment regardless of re-ignition sources
- B. Its excellent cooling ability
- C. Its good stability and non-toxicity
- D. All of the above
10. The state of charge of a stored-pressure type dry chemical fire extinguisher can be readily determined by ____.
- A. Visual inspection of the pressure gauge
- B. Weighing the cylinder
- C. Removing the lid and checking the level of dry chemical
- D. Weighing the CO2 cartridge
11. A class B fire is most successfully fought by ____.
- A. Preventing oxygen from reaching the burning material
- B. Cooling the burning material below its ignition temperature
- C. Using the extinguishing agent to make the burning material fire-resistant
- D. Using the extinguishing agent to absorb the heat
12. Fires of which classes would most likely occur in the engine room of a ship?
- A. Classes A and B
- B. Classes B and C
- C. Classes C and D
- D. Classes A and D
13. Oily rags stored in a pile that is open to the atmosphere are a hazard because they may ____.
- A. Deteriorate and give off noxious gases
- B. Spontaneously heat and catch fire
- C. Attract lice and other vermin and serve as a breeding ground
- D. None of the above
14. Which danger exists to people when CO2 is discharged into a small enclosed space?
- A. Damaged eardrums
- B. Electric shock
- C. Frostbite
- D. Respiratory arrest
15. Which statement is TRUE concerning carbon dioxide?
- A. It is lighter than air
- B. It is used mostly on class A fires
- C. It is an inert gas
- D. All of the above
16. An advantage of an ABC dry chemical extinguisher over a carbon dioxide extinguisher is ____.
- A. Lack of toxicity
- B. The multipurpose extinguishing ability
- C. Cooling ability
- D. Burn-back protection
17. One gallon of high-expansion foam solution will produce ____.
- A. 8 to 10 gallons of foam
- B. 25 to 50 gallons of foam
- C. 100 to 200 gallons of foam
- D. 500 to 1000 gallons of foam
18. The preferred agent used in fighting a helicopter crash fire is ____.
- A. CO2
- B. Dry chemical
- C. Water
- D. Foam
19. Which statement is TRUE about firefighting foam?
- A. The air bubbles in foam act as an insulator in fighting a class C fire
- B. The effectiveness of foam in forming a blanket over a burning liquid increases as the temperature of the liquid increases
- C. Foam can be used to control gases escaping from compressed gas cylinders
- D. Foam sets up a vapour barrier over a flammable liquid, preventing flammable gases from rising
20. When fighting an oil or gasoline fire in the bilge, which of the following should NOT be used?
- A. All-purpose nozzle
- B. Carbon dioxide
- C. Foam
- D. Solid stream water nozzle
21. The canvas covering of a fire hose is called the ____.
- A. Casing
- B. Jacket
- C. Line cover
- D. Outer hose
22. Which of the following statements is FALSE concerning the proper procedure in handling a fire hose?
- A. A 1-1/2 inch hose should be deployed with a minimum of a nozzleman and a hoseman
- B. The nozzleman should always hold the nozzle with one hand on top, to prevent kickback
- C. Back-up hosemen should be placed wherever the hose makes a significant turn
- D. Use of a spanner wrench when attaching nozzles or additional lengths of hose is always critical
23. To remedy a leaking fire hose connection at the hydrant, secure the valve and ____.
- A. Reduce fire pump pressure
- B. Replace the gasket in the male coupling
- C. Replace the gasket in the female coupling
- D. Rethread the male coupling
24. Which instrument is suitable for determining the presence of explosive concentrations of fuel oil vapours in tanks?
- A. A flame safety lamp
- B. A liquid cargo meter
- C. A combustible gas indicator
- D. All of the above
25. Which type of fire extinguisher do you use to fight an electrical fire if a carbon dioxide extinguisher is unavailable?
- A. Water
- B. Wet chemical
- C. Foam
- D. Dry powder
26. You should avoid using ____ when extinguishing a fire in a confined space.
- A. Dry powder fire extinguishers
- B. Water fire extinguishers
- C. Foam fire extinguishers
- D. Wet chemical fire extinguishers
27. A deck-stowed 40-foot container is giving off smoke, and one end is discoloured from heat. The cargo is valuable and easily damaged by water. You want to extinguish the fire without further damage if possible. What action should you take?
- A. Connect a portable line from the ship's fixed system and discharge CO2 into the container
- B. Cool the exterior of the container with water and close all vents, then keep it cooled until it can be off-loaded
- C. Pierce the container and discharge 6 or more portable CO2 extinguishers, then add more CO2 hourly
- D. Flood the container with water and disregard any cargo damage as the fire threatens the entire vessel
28. If heavy smoke is coming from the paint locker, the FIRST firefighting response should be to ____.
- A. Open the door to evaluate the extent of the fire
- B. Enter and use a portable extinguisher
- C. Secure the ventilation
- D. Release the CO2 flooding system
29. A carbon dioxide fire extinguisher is required to be recharged if the weight loss exceeds what percentage of the weight of the charge?
- A. One percent
- B. Five percent
- C. Seven percent
- D. Ten percent
30. The usual method for effectively applying foam on a fire is by ____.
- A. Spraying directly on the base of the fire
- B. Flowing the foam down a vertical surface
- C. Sweeping the fire with the foam
- D. Spraying directly on the surface of the fire
Set 9 — 30 AFF exit exam questions with answers
1. When compared to a high-expansion foam, a low-expansion foam will ____.
- A. Be drier
- B. Be more heat resistant
- C. Cling to vertical surfaces
- D. Be lighter
2. Which extinguishing agent is best for use on a magnesium fire?
- A. Water
- B. Sand
- C. CO2
- D. Dry chemical
3. Which extinguishing agent will absorb the most heat?
- A. Water
- B. CO2
- C. Dry chemical
- D. Foam
4. What is the most vulnerable part of the fire main system?
- A. The fire pump
- B. Exposed hard piping
- C. The hydrant valve
- D. The fire hose
5. As per SOLAS, what is the minimum number of portable fire extinguishers to be carried in accommodation, service spaces and control stations of a cargo ship of 1,000 GT and upwards?
- A. 1
- B. 4
- C. 5
- D. 3
6. When fighting a fire in an enclosed space, the hose team should crouch as low as possible to ____.
- A. Protect themselves from smoke
- B. Obtain the best available air
- C. Allow the heat and steam to pass overhead
- D. All of the above
7. The most likely location for a liquid cargo fire to occur on a tanker would be ____.
- A. In the midships house
- B. At the main deck manifold
- C. At the vent header
- D. In the pump room
8. To get low-velocity fog from an all-purpose nozzle, you would ____.
- A. Attach an applicator to the solid stream outlet on the nozzle
- B. Attach an applicator to the nozzle in place of the high-velocity nozzle tip
- C. Attach the high-velocity nozzle tip to the fog outlet of the nozzle
- D. Simply move the handle to the vertical position on the nozzle
9. To prevent the spread of fire by conduction you should ____.
- A. Cool the bulkheads around the fire
- B. Remove combustibles from direct exposure
- C. Close all openings to the area
- D. Shut off all electric power
10. The spread of fire is prevented by ____.
- A. Heating surfaces adjacent to the fire
- B. Removing combustibles from the endangered area
- C. Increasing the oxygen supply
- D. All of the above
11. What is an advantage of water fog or water spray over a straight stream of water in fighting an oil fire?
- A. It has a smothering effect on the fire
- B. It requires less water to remove the same amount of heat
- C. It gives more protection to firefighting personnel
- D. All of the above
12. The difference in water spray pattern between the high-velocity tip and low-velocity applicator used with the all-purpose nozzle is due to ____.
- A. A difference in water pressure
- B. The method of breaking up the water stream
- C. The length of the applicator
- D. All of the above
13. One advantage of the all-purpose nozzle is that it ____.
- A. Can fit any size hose
- B. Converts a stream of water into a fog
- C. Increases the amount of water reaching the fire
- D. Can spray two streams of water at the same time
14. You are tending the lifeline of a person who has entered a compartment wearing a breathing apparatus. How many tugs of the lifeline mean "Are you all right?"
- A. One
- B. Two
- C. Three
- D. Four
15. A serious fire has been isolated in the engine room. You would ____.
- A. Wait for it to burn itself out
- B. Open the vents to let the smoke out
- C. Spray cooling water on bulkheads of the adjacent compartments
- D. Enter to extinguish the fire with a water extinguisher
16. You are in a tank wearing a self-contained breathing apparatus and you desire to return topside. How many tugs of the lifeline mean to take up the slack?
- A. One
- B. Two
- C. Three
- D. Four
17. When the bypass valve of a self-contained breathing apparatus is opened, the mainline valve should be ____.
- A. Completely open
- B. Completely closed
- C. Pinched to check the air flow
- D. Immediately disconnected
18. The spray of water in low-velocity fog will have ____.
- A. Greater range than high-velocity fog
- B. Lesser range than high-velocity fog
- C. About the same range as high-velocity fog
- D. Greater range than a solid stream
19. When an oil fire has been extinguished, the surface of the oil should be kept covered with foam to prevent ____.
- A. Air from contacting the oil vapours, permitting re-ignition
- B. Boiling of the heated oil
- C. Spontaneous combustion below the surface
- D. Toxic fumes from escaping to the surface
20. The ship is divided into main vertical and horizontal zones by thermal and structural boundaries in order ____.
- A. To improve stability
- B. To improve and contain fire safety
- C. To reduce the cost of construction
- D. None of the above
21. Violent flames and heavy black smoke are typical of which sort of fire?
- A. Wood fire
- B. Paper fire
- C. Fuel oil fire
- D. Electrical fire
22. In pump rooms and pipe tunnels, flameproof electric light fittings are generally fitted. This means that ____.
- A. The fitting is completely gas-tight and no gas can come into contact with the bulb and electrical connections
- B. Gas may enter, but if an explosion takes place inside, the fitting is strong enough to contain it without igniting the surrounding atmosphere
- C. The electrical supply will disconnect automatically in case of fire
- D. Even if a fire occurs, it will not consume the fitting
23. A portable cartridge-type dry chemical fire extinguisher discharges by ____.
- A. Gravity when the extinguisher is turned upside down
- B. Pressure from a small CO2 cartridge on the extinguisher
- C. Air pressure from a hand pump attached to the extinguisher
- D. Pressure from the reaction when water is mixed with the chemical
24. What is fuel's role in making a fire?
- A. It is the combustible material that burns
- B. It is the food that gives your body energy
- C. It is one thing you do not need to make a fire
- D. None of these
25. An aluminium powder fire is classified as class ____.
- A. A
- B. B
- C. C
- D. D
26. In case of fire on an electrical motor, the first thing to do is ____.
- A. Call the electrician
- B. Extinguish the fire by water spray
- C. Sound the alarm, stop the motor and extinguish using CO2
- D. Extinguish using a foam extinguisher
27. A fire hose has a ____.
- A. Female coupling at the nozzle end and a male coupling at the hydrant end
- B. Female coupling at both ends
- C. Male coupling at both ends
- D. Male coupling at the nozzle end and a female coupling at the hydrant end
28. All of the following are part of the fire triangle EXCEPT ____.
- A. Fuel
- B. Electricity
- C. Oxygen
- D. Heat
29. One of the limitations of foam as an extinguishing agent is that foam ____.
- A. Cannot be made with salt water
- B. Is heavier than oil and sinks below its surface
- C. Is corrosive and a hazard to fire fighters
- D. Conducts electricity
30. A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the ____.
- A. Fire pumps are used for purposes other than supplying water to the fire main
- B. Fire hose might be damaged by cargo operations
- C. Fire main system is not charged
- D. Vessel is in port
Set 10 — 30 AFF exit exam questions with answers
1. A fire in the galley ALWAYS poses the additional threat of ____.
- A. A grease fire in the ventilation system
- B. Causing loss of stability
- C. Contaminating food with extinguishing agent
- D. Spreading through the engineering space
2. A concentration of only ____ of CO2 in air will induce rapid unconsciousness.
- A. 1%
- B. 10%
- C. 70%
- D. 0.33%
3. What is the best method for extinguishing a fire of escaping liquefied flammable gas?
- A. Cooling the gas below its ignition point
- B. Stopping the flow of gas
- C. Interrupting the chain reaction
- D. Cutting off the supply of oxygen
4. For fighting fire on the cargo deck of a tanker, the system used is ____.
- A. Low-expansion foam
- B. High-expansion foam
- C. DCP
- D. CO2
5. A spanner is a ____.
- A. Special tool for fighting pirates
- B. Special tool for removing the cylinder head
- C. Special wrench for the couplings in a fire hose line
- D. None of these
6. If you are the first person to discover a fire, what should you do?
- A. Leave the area immediately
- B. Head to your locker and get your personal items
- C. Pick up a fire extinguisher and tackle the fire
- D. Activate the fire alarm
7. Fire can be caused on board a vessel by ____.
- A. A high DC power supply
- B. Low batteries
- C. A low AC power supply
- D. Faulty electrical leads
8. What is the requirement for an escape route door opening?
- A. It must be capable of being opened from the direction in which escape is required
- B. It must be capable of opening in both directions
- C. It must be capable of opening only from outside to inside
- D. It must not be opened without permission
9. After using a CO2 portable extinguisher, it should be ____.
- A. Put back in service if some CO2 remains
- B. Hydrostatically tested
- C. Retagged
- D. Recharged
10. What quantity of reserve fuel is to be available for a diesel-driven emergency fire pump outside the main machinery space?
- A. 20 litres
- B. 40 litres
- C. Sufficient for 6 hours' operation at full capacity
- D. Sufficient for 15 hours' operation at full capacity
11. Structural fire protection refers to the passive measures taken to ____.
- A. Provide a vessel with a sprinkler system
- B. Provide a vessel with firefighting equipment
- C. Limit the risk and spread of fire
- D. Limit the size of the engine room
12. What fixed fire-fighting medium is normally used in the engine room, pump room and other such spaces?
- A. CO2 flooding system
- B. Portable foam fire extinguisher
- C. Portable CO2 fire extinguisher
- D. None of these
13. What type of permit is needed in order to carry out work that could potentially result in a fire breaking out on the work site?
- A. A fire permit
- B. A hot work permit
- C. A cold work permit
- D. No permit is needed
14. Fire blankets are used for ____.
- A. Smothering a fire
- B. Cooling a fire
- C. Inhibiting a fire
- D. Starving a fire
15. A fire of carbonaceous substances is known as a ____.
- A. Class A fire
- B. Class B fire
- C. Class C fire
- D. Class D fire
16. The principle of operation of a fire detector could be based on ____.
- A. A bimetallic strip
- B. Fusible links
- C. A quartzoid bulb
- D. All the above
17. Which ships shall be provided with an international shore connection for the supply of water as an extinguishing medium?
- A. Tankers only
- B. All ships of 500 GT and upwards
- C. Passenger ships carrying more than 36 passengers
- D. Passenger ships of 100 GT and upwards
18. Why is it important that you take care with the nozzle when you have finished using a fire extinguisher containing carbon dioxide?
- A. Because the nozzle gets extremely hot, making it impossible to hold
- B. This is not a requirement
- C. Because the nozzle gets warm, making it impossible to hold
- D. Because the nozzle gets extremely cold, making it impossible to hold
19. Which of the following is correct regarding the types of fire extinguisher you should avoid while fighting a fire in a confined space?
- A. Carbon dioxide and dry powder fire extinguishers should not be used
- B. Carbon dioxide and water fire extinguishers should not be used
- C. Water and dry powder fire extinguishers should not be used
- D. Only a dry powder fire extinguisher should not be used
20. Who has the authority to activate the fire alarm after discovering a fire on the worksite?
- A. Only the master can activate the fire alarm
- B. Anyone who has seen a fire can activate the fire alarm
- C. Only the fire safety officer can activate the fire alarm
- D. Only the crew can activate the fire alarm
21. Where should you go if you hear the fire alarm going off?
- A. To the supervisor's office to inform him what is happening
- B. To the assembly point (muster station)
- C. To the break room to make sure everyone got out
- D. Home, as the work day is over
22. During a fire, which means of communication may be used?
- A. Messengers
- B. Telephones
- C. Walkie-talkies
- D. All of the above
23. The fire assembly point can be best described as:
- A. The place where the fire extinguishers are stored
- B. An area that has a high risk of fire
- C. An area where you are required to assemble in the event of a fire
- D. An area you are required to avoid in the event of a fire
24. When must portable carbon dioxide fire extinguishers be recharged?
- A. At least once each year
- B. Each time the vessel dry-docks
- C. When the charged weight has decreased by 50%
- D. Whenever used, including for demonstration or fire fighting on board
25. In a mixture of flammable vapour and air, if there is too much vapour and not enough air to support combustion, the mixture is said to be:
- A. Too rich
- B. Over-concentrated
- C. Too lean
- D. Saturated
26. Automatic sprinklers in accommodation spaces shall come into operation within the temperature range of:
- A. 80 - 90 °C
- B. 68 - 79 °C
- C. 56 - 67 °C
- D. 48 - 55 °C
27. Class A materials do not include which of the following?
- A. Wood
- B. Propane
- C. Plastics
- D. Paper
28. What does the term 'spontaneous combustion' mean?
- A. The substance is very difficult to set alight, even when very hot
- B. When the substance burns it burns completely and leaves no residue or ash
- C. When the substance burns it becomes very hot
- D. The substance can catch fire by itself without an external source of heat or ignition
29. Continuous burning of a fire is represented in the fire tetrahedron by the addition of:
- A. Chain supply
- B. Chain reaction
- C. Chain inhibition
- D. Chain prevention
30. When you are using a carbon dioxide fire extinguisher, what happens to the nozzle (horn)?
- A. It becomes extremely hot
- B. It becomes warm
- C. It becomes slightly cold
- D. It becomes extremely cold
Set 11 — 30 AFF exit exam questions with answers
1. Titanium and aluminium can be classified under which class of fire?
- A. Class A
- B. Class C
- C. Class D
- D. Class B
2. If there is a black coloured band on a fire extinguisher, what does the colour of the band tell you?
- A. That this is a wet chemical fire extinguisher
- B. That this is a carbon dioxide fire extinguisher
- C. That this extinguisher is broken and should not be used
- D. That this is a dry powder fire extinguisher
3. ____ fire extinguishers are specifically designed to tackle a Class F fire.
- A. Dry chemical
- B. Water
- C. Foam
- D. Wet chemical
4. If a cream coloured band is located on a fire extinguisher, it indicates that the extinguisher is of which type?
- A. CO2
- B. Water
- C. Foam
- D. None of these
5. Wood, plastic and paper are classified as:
- A. Class B
- B. Class C
- C. Class A
- D. Class D
6. A portable foam (stored-pressure type) fire extinguisher would be most useful in combating a fire in:
- A. Oil drums
- B. Cargo tanks
- C. A large fire
- D. None of these
7. A stored-pressure water extinguisher is most effective against fires of class:
- A. C
- B. A
- C. D
- D. B
8. Any extinguishing agent used on a Class C (electrical) fire must have which important property?
- A. Conductivity
- B. Expansion
- C. Temperature
- D. Non-conductivity
9. A fire in trash and paper waste is classified as class:
- A. A
- B. C
- C. D
- D. B
10. A fire in a pile of dunnage would be classified as class:
- A. B
- B. D
- C. C
- D. A
11. A fire in a pile of canvas is classified as class:
- A. D
- B. C
- C. A
- D. B
12. The best way to fight an electrical fire from the options given is with:
- A. Water
- B. Foam
- C. Dry chemical powder (DCP)
- D. None of these
13. A foam-type portable fire extinguisher would be most useful in combating a fire in:
- A. Combustible metallic solids
- B. A piece of electrical equipment
- C. Solid materials such as wood or bales of fibre
- D. Flammable liquids
14. What type of fire extinguisher should you use to extinguish a fire in solid materials such as wood, paper or textiles?
- A. Carbon dioxide
- B. Water
- C. Foam
- D. Wet chemical
15. A portable fire extinguisher is designed to put out ____ effectively.
- A. A big fire
- B. A small fire
- C. An uncontrollable fire
- D. None of these
16. Water fire extinguishers have a ____ located on them.
- A. Red coloured band
- B. Red and cream band
- C. Red and yellow band
- D. Yellow coloured band
17. A dry powder fire extinguisher can be identified by a ____ band on it.
- A. Green
- B. Yellow
- C. Blue
- D. Black
18. An initial attempt to extinguish a galley grease fire may be made by using:
- A. Water
- B. A mechanical foam system
- C. The range hood extinguishing system
- D. Fire dampers only
19. When using a foam fire extinguisher on a fire in the engine room, the best way is to:
- A. Direct the foam on the bulkhead behind the fire and let it slowly spread over the fire
- B. Spread the foam from the side of the fire towards the inside
- C. Aim directly at the fire with a sweeping action
- D. Spray the high flames first
20. A self-contained breathing apparatus should have a minimum air duration of:
- A. 10 minutes
- B. 20 minutes
- C. 30 minutes
- D. 40 minutes
21. A sliding watertight door below the waterline should be able to be closed manually (by hand gear) within how many seconds with the ship upright?
- A. 10 seconds
- B. 30 seconds
- C. 40 seconds
- D. 90 seconds
22. In addition to the fixed fire-fighting systems, what else is a special requirement for tankers?
- A. Lifeboats provided with a water spray (sprinkler) system
- B. Sprinkler system in the accommodation
- C. An extra rescue boat
- D. Automatic release of CO2
23. The inert gas system shall be capable of maintaining the oxygen content in the cargo tanks at not more than:
- A. 5% by volume
- B. 7% by volume
- C. 8% by volume
- D. 10% by volume
24. Why is carbon dioxide better than dry chemical for fighting a Class C (electrical) fire?
- A. Dry chemical is a conductor
- B. Dry chemical leaves a residue
- C. CO2 will not dissipate in the air
- D. A smaller amount of CO2 covers the same area
25. The proper method of using a fire extinguisher is remembered as:
- A. Pull, aim, squeeze, sweep
- B. Pass, aim, shut, sit
- C. Push, aim, spray, step
- D. Pull, alert, squeeze, stop
26. What is a door release unit (DRU)?
- A. An electromagnetic device that holds a fire door open and releases it to close when the fire alarm operates
- B. An automatic release unit for the rescue boat
- C. An automatic release unit for the lifeboat
- D. None of the above
27. What is the correct way to use a CO2 fire extinguisher?
- A. Direct it on a bulkhead behind the fire and let it flow down
- B. Aim low, pointing the horn at the base of the fire, and sweep from side to side
- C. Hold it by the horn while discharging
- D. Direct it at the high flames first and then the low flames
28. To fight a Class C (electrical) fire you should use carbon dioxide or:
- A. Chemical foam
- B. Mechanical foam
- C. Dry chemical
- D. Chemically treated sawdust
29. A fire on board is extinguished by:
- A. Cooling
- B. Smothering (cutting off oxygen)
- C. Starvation (removing the burning material or fuel)
- D. All of the above
30. On fire patrol at night you see smoke coming from under a closed cabin door. What action should you take?
- A. Activate the nearest fire alarm call point and advise the bridge of the location of the fire
- B. As most people are sleeping, call a friend to assist in putting out the fire
- C. Get the nearest fire extinguisher and then open the door to see the situation
- D. Look inside the cabin to see what the situation is
Set 12 — 30 AFF exit exam questions with answers
1. Why should a CO2 extinguisher be used with caution in confined areas?
- A. It will increase the oxygen in the confined area to a dangerous level
- B. It may explode when exposed to heat
- C. It will displace the air and reduce the oxygen available
- D. It will not operate effectively in confined areas
2. You are carrying out a search in a smoke-filled compartment wearing a BA set. At what stage should you start to make your way out of the compartment?
- A. When the BA set low-pressure warning whistle sounds
- B. 15 minutes after starting to use the set, as this leaves five minutes of air
- C. Regularly check the pressure gauge and note the air used to reach the work area; start to return when this amount plus a reasonable reserve is left
- D. None of the above
3. For fire to occur, the three elements of the fire triangle must be present. These are heat, air (oxygen) and ____.
- A. Electricity
- B. Spark
- C. Flame
- D. Fuel
4. If you were in charge of a fire team, what is the minimum number of persons wearing BA sets that you would allow to enter a smoke-filled compartment?
- A. 2 persons
- B. 1 person
- C. 3 persons
- D. 4 persons
5. What class of fire is a smouldering fire of wood, textiles, paper and other carbonaceous materials?
- A. Class A
- B. Class B
- C. Class C
- D. Class D
6. What is the primary hazard, other than fire damage, associated with a Class C fire?
- A. Flashover
- B. Possibility of re-flash
- C. Electrocution or shock
- D. Explosion
7. A document which identifies a chemical and lists its physical properties, health hazards, required controls, fire-fighting procedures, clean-up methods, waste disposal and safe handling is commonly called a ____.
- A. Hazardous chemical information sheet
- B. Material safety data sheet
- C. Hazardous chemical loading document
- D. Physical or chemical characteristics document
8. Which of the following is not required to be shown on a vessel's fire control plan?
- A. Ventilation fan locations
- B. Ventilation fan capacity
- C. Ventilation fan controls
- D. Ventilation dampers
9. The longer an oil fire is permitted to burn, the ____.
- A. Harder it is to extinguish
- B. Easier it is to extinguish
- C. Less chance there is of re-ignition
- D. Easier it is to control
10. Which of the following is specially dedicated to receiving water supplied from shore?
- A. Isolating valve
- B. International shore connection
- C. Fire main line
- D. None of the above
11. Spontaneous combustion is caused by ____.
- A. An outside heat source heating a substance until it ignites
- B. Conduction of heat through a wall of material to the substance
- C. Chemical action within the substance
- D. All of the above
12. In cargo ships the diameter of the fire main need only be sufficient for the discharge of ____ with two fire pumps simultaneously delivering through nozzles.
- A. 135 m³/h
- B. 145 m³/h
- C. 14 m³/h
- D. 140 m³/h
13. A hand portable CO2 fire extinguisher is effective on burning oil only ____.
- A. If applied promptly
- B. If applied together with foam
- C. To prevent rekindling
- D. If an attempt with low-velocity fog has failed
14. Which toxic gas is a product of incomplete combustion and is often present when a fire burns in a closed compartment?
- A. Hydrogen sulphide
- B. Carbon monoxide
- C. Carbon dioxide
- D. Nitric oxide
15. Before releasing the engine room fixed CO2 system to extinguish a major uncontrolled fire, what is the first step?
- A. Stop the main engine
- B. Evacuate all engine room personnel
- C. Start the emergency diesel generator
- D. Turn off electrical power
16. Which type of fire extinguisher is hard to recharge on board?
- A. DCP
- B. Foam
- C. CO2
- D. Water
17. A fire in an engine compartment is best extinguished with carbon dioxide gas and by ____.
- A. Completely closing the compartment
- B. Closing the compartment except for the ventilators
- C. Leaving the compartment open to the air
- D. Increasing the air flow to the compartment with blowers
18. Fire fighting with foam is only effective when the foam ____.
- A. Penetrates to the bottom of the fire
- B. Mixes with the burning fuel oil
- C. Is kept saturated with low-velocity water fog
- D. Completely covers the top of the burning liquid
19. As per regulations, the minimum length of a fireman's lifeline should be ____.
- A. 30 metres
- B. 20 metres
- C. 15 metres
- D. None of the above
20. The main advantage of a solid (straight) stream of water on a Class A fire is that it ____.
- A. Removes the oxygen
- B. Washes the fire away
- C. Protects the fire-fighting crew
- D. Breaks up and cools the burning material
21. What is the best fire-fighting medium for a cargo fire on a gas tanker?
- A. Water
- B. Foam
- C. DCP
- D. Carbon dioxide
22. If a portable carbon dioxide fire extinguisher has been partially discharged, it should be immediately:
- A. Tagged and restowed properly in its rack
- B. Weighed and the charge loss recorded before returning it to its rack
- C. Given to the chief engineer for charging
- D. Tagged 'empty' and stowed separately from charged extinguishers
23. The outlet of a fire hydrant may be positioned anywhere from horizontal to pointing ____.
- A. Vertically downward
- B. Vertically upward
- C. 45 degrees upward
- D. All of the above
24. The maximum mass of a portable fire extinguisher is:
- A. 11 kg
- B. 23 kg
- C. 19 kg
- D. 9 kg
25. CO2 fire extinguishers are preferred over other types because they:
- A. Are cheaper per unit
- B. Do less damage than others
- C. Are better at cooling
- D. None of the above
26. During an investigation of a fire, which points will be considered?
- A. How the fire was discovered
- B. When the fire was reported and the alarm sounded
- C. Communication between the teams
- D. All of the above
27. Fire fighting on board comprises which sequence of actions?
- A. Find, alarm, isolate and extinguish
- B. Find, fight and report
- C. Report and fight
- D. Find and report to the company
28. A CO2 fire extinguisher can be used for fighting which classes of fire?
- A. A and C
- B. B and C
- C. A and B
- D. C, D and E
29. There are two disadvantages of CO2 when used as a total flooding fire-fighting agent. One is that extinguishing concentrations will not support human life; the other is ____.
- A. The lack of cooling effect on heated materials
- B. It breaks down under extreme heat to form poisonous gases
- C. It cannot be used in a dead-ship situation without power for the CO2 pump
- D. It has no effect on a Class A fire even in an enclosed space
30. Which flammable materials kept in a store can cause a fire?
- A. Paints and varnishes
- B. Cleaning fluids and thinners
- C. Steel wire ropes
- D. Both paints/varnishes and cleaning fluids/thinners
Set 13 — 30 AFF exit exam questions with answers
1. The operating temperature of a green-coloured glass bulb in a sprinkler head is ____.
- A. 63 °C
- B. 93 °C
- C. 85 °C
- D. 78 °C
2. The fire detection and alarm system normally works on ____.
- A. 12 V DC
- B. 24 V DC
- C. 24 V AC
- D. 220 V DC
3. What is the first thing you should do in case of a fire if you cannot reach a fire extinguisher?
- A. Open the portholes to clear the smoke
- B. Evacuate the room immediately
- C. Keep searching for an extinguisher
- D. Fight the fire with whatever is at hand
4. What is the temperature at which a material produces enough flammable vapour to flash if exposed to an ignition source?
- A. Melting point
- B. Ignition temperature
- C. Auto-ignition temperature
- D. Flash point
5. In the event of a fire, the doors to a stair tower must be closed to prevent the spread of fire by:
- A. Radiation
- B. Conduction
- C. Convection
- D. Ventilation
6. Low-expansion foam has an expansion ratio of:
- A. Up to 20:1
- B. 20:1 to 200:1
- C. 200:1 to 1000:1
- D. Above 1000:1
7. In the list below, which gas has the widest flammable range?
- A. Ethylene
- B. Propane
- C. Butane
- D. Methane
8. The abbreviation AFFF stands for:
- A. Aqueous Film Forming Foam
- B. Alcohol Fire Fighting Foam
- C. Aerated Fluid Fire Foam
- D. Automatic Fixed Fire Fighting
9. Under the NFPA (US) classification, a Class K fire involves:
- A. Combustible metals
- B. Cooking oils and fats
- C. Energised electrical equipment
- D. Flammable gases
10. 'B' class divisions (bulkheads) are classified as:
- A. B-15 and B-0
- B. A-60, A-30, A-15 and A-0
- C. C-15 and C-0
- D. H-120 and H-60
11. A fire patrol should use which senses to identify a fire?
- A. Sight only
- B. Hearing and taste
- C. Sight, smell and touch
- D. Smell only
12. Which types of portable fire extinguishers are carried on board ships?
- A. CO2 and foam only
- B. Foam only
- C. CO2 only
- D. Water, foam, dry powder and CO2
13. Power-operated sliding watertight doors below the waterline must close, with the ship upright, in a time of:
- A. Not less than 20 s and not more than 40 s
- B. Not more than 45 s
- C. Not more than 90 s
- D. Not more than 10 s
14. Before opening a closed door during a fire, you should always:
- A. Open it quickly to assess the situation
- B. Check the door for heat with the back of your hand
- C. Kick the door open
- D. Spray water under the door first
15. When should a fire watch be maintained for hot work activities?
- A. Only before the hot work starts
- B. Only during the hot work
- C. During the hot work and for a period after it is completed
- D. Only after the hot work is completed
16. Quick-closing valves on fuel oil tanks are designed to be operated from:
- A. Only locally at the valve
- B. A remote position outside the space concerned
- C. Only from the bridge
- D. Only from inside the tank
17. In a cargo ship, the total required capacity of the fire pumps (other than the emergency fire pump) need not exceed ____.
- A. 80 m³/h
- B. 120 m³/h
- C. 180 m³/h
- D. 250 m³/h
18. In an automatic sprinkler system, sprinkler heads are spaced not more than ____ apart and not more than 2 m from any bulkhead or ship's side forming a boundary of the protected space.
- A. 2 m
- B. 4 m
- C. 6 m
- D. 8 m
19. How is the automatic sprinkler system connected to the ship's fire main?
- A. It is not connected; it has only its own pressure tank
- B. Through a lockable screw-down non-return valve
- C. Through a direct open connection with no valve
- D. Through the CO2 manifold
20. The maximum distance between the centres of heat detectors is ____.
- A. 5 m
- B. 9 m
- C. 11 m
- D. 15 m
21. Which of the following cargoes is liable to spontaneous combustion?
- A. Coal
- B. Iron ore
- C. Granite chips
- D. Cement clinker
22. For a 'B' class division, the average temperature on the unexposed side must not rise more than ____ above the original temperature within the first 30 minutes of the standard fire test (B-15).
- A. 100°C
- B. 140°C
- C. 180°C
- D. 225°C
23. When the human body is exposed to carbon monoxide, what happens to the oxygen supply to the tissues?
- A. It increases because CO stimulates breathing
- B. It decreases because CO combines with haemoglobin in preference to oxygen
- C. It is unaffected because CO is an inert gas
- D. It increases because CO dilates blood vessels
24. Charcoal is a product of the ____ of wood.
- A. Dry distillation
- B. Complete combustion
- C. Hydrolysis
- D. Fermentation
25. An injury caused by wet heat such as hot water or steam is called a ____.
- A. Burn
- B. Scald
- C. Frostbite
- D. Blister
26. Each section of an automatic sprinkler system must maintain an average water application rate of not less than ____ over the protected area.
- A. 2 l/m²/min
- B. 5 l/m²/min
- C. 8 l/m²/min
- D. 10 l/m²/min
27. A non-combustible material is one which neither burns nor gives off flammable vapours in sufficient quantity for self-ignition when heated to approximately ____.
- A. 450°C
- B. 600°C
- C. 750°C
- D. 900°C
28. What is the minimum number of fireman's outfits required on a cargo ship?
- A. 1
- B. 2
- C. 3
- D. 4
29. Which of the following is NOT a component of the fire tetrahedron?
- A. Heat
- B. Fuel
- C. Oxygen
- D. Nitrogen
30. What is the generally accepted minimum CO2 design concentration needed to extinguish a fire in a machinery space?
- A. 20%
- B. 34%
- C. 45%
- D. 50%
Set 14 — 30 AFF exit exam questions with answers
1. Which type of foam is most effective against fires in water-miscible (polar) flammable liquids such as alcohol?
- A. Protein foam
- B. AFFF (Aqueous Film Forming Foam)
- C. AR-AFFF (Alcohol-Resistant AFFF)
- D. Synthetic foam
2. Which SOLAS chapter mainly deals with fire protection, fire detection and fire extinction on ships?
- A. Chapter II-1
- B. Chapter II-2
- C. Chapter III
- D. Chapter IV
3. What is the main hazard of a backdraft during a shipboard fire?
- A. Excessive water damage
- B. Sudden explosive ignition when oxygen is reintroduced
- C. Rapid cooling of the compartment
- D. Increased smoke density
4. When entering a smoke-filled compartment, what is the correct buddy-system rule for firefighters?
- A. One firefighter enters alone with radio contact
- B. A minimum of two firefighters always enter together
- C. Three firefighters enter while one monitors outside
- D. Entry is not permitted under any circumstances
5. What does 'flash point' mean in fire fighting?
- A. The temperature at which a substance auto-ignites
- B. The lowest temperature at which a liquid gives off enough vapour to ignite momentarily when an external ignition source is applied
- C. The temperature at which continuous burning begins
- D. The highest temperature a fuel can reach
6. Which portable fire-fighting medium should NOT be used on a Class B fire (flammable liquids)?
- A. Dry powder
- B. CO2
- C. Foam
- D. Water jet
7. What is the main purpose of the emergency fire pump on a ship?
- A. To supply foam concentrate to monitors
- B. To provide an independent water supply if the main fire pumps fail
- C. To pressurise the inert gas system
- D. To supply water to the CO2 room
8. In which situation should the fixed CO2 system NOT be released immediately into a machinery space?
- A. When a major fuel oil fire is confirmed
- B. When all personnel have not yet been evacuated from the space
- C. When the fire has spread to the bilges
- D. When the main engine is running
9. What is the correct action when a self-contained breathing apparatus (SCBA) low-pressure warning alarm activates?
- A. Continue the operation and finish the task
- B. Immediately withdraw from the compartment
- C. Switch to a secondary air supply inside the space
- D. Remove the mask and breathe ambient air
10. What is the main purpose of a thermal imaging camera (TIC) during fire fighting?
- A. To measure smoke concentration levels
- B. To detect heat sources through smoke and darkness
- C. To communicate with shore-based fire brigades
- D. To identify the type of fuel burning
11. What does 'foam expansion ratio' mean?
- A. The rate at which foam concentrate is mixed with water
- B. The volume of finished foam produced from a unit volume of foam solution
- C. The thickness of the foam blanket applied on a fire
- D. The pressure at which foam is discharged
12. Which part of the fireman's outfit protects the hands from heat and flame?
- A. Safety boots
- B. Fire-resistant gloves
- C. Lifeline
- D. Safety lamp
13. What is the main cause of most deaths in shipboard fires?
- A. Burns from direct flame contact
- B. Explosion injuries
- C. Smoke inhalation and toxic gases
- D. Structural collapse
14. How should a hose team position itself when attacking a cargo hold fire through a hatch?
- A. Directly above the open hatch
- B. At the side of and slightly upwind of the hatch opening
- C. Below the hatch on the cargo deck
- D. Inside the hold at the base of the fire
15. Which is a correct technique for a Class A fire in an enclosed space?
- A. Apply dry powder and close the space
- B. Apply water in a fog pattern to cool and suppress the fire
- C. Introduce CO2 without any water
- D. Ventilate the space fully before applying foam
16. What is the function of a 'deadman' (distress signal) alarm on an SCBA set?
- A. It signals when the oxygen level drops below 21%
- B. It activates when the wearer remains motionless for a set period, indicating incapacitation
- C. It measures ambient temperature inside a fire compartment
- D. It triggers automatic foam release
17. Which type of fire detector senses products of combustion by their effect on ionised air in a chamber?
- A. Heat detector
- B. Optical smoke detector
- C. Ionisation detector
- D. Flame detector
18. What is the correct procedure before opening a door or hatch to a space affected by fire?
- A. Open it quickly to provide ventilation to firefighters
- B. Feel the door for heat and keep to the hinged side, shielded by the door, when opening
- C. Immediately break the door down using an axe
- D. Spray water through the door gap and open it fully at once
19. Which IMO instrument requires a fire safety training manual to be provided on board ships?
- A. ISM Code
- B. SOLAS Regulation II-2/15
- C. MARPOL Annex I
- D. STCW Code Section A-VI/3
20. What is the main advantage of a high-expansion foam system in an enclosed space?
- A. It provides oxygen to personnel inside
- B. It rapidly fills the space, smothering the fire and displacing oxygen
- C. It cools the fire by high-pressure water discharge
- D. It prevents re-ignition through a chemical reaction
21. When carrying out search and rescue in a smoke-filled compartment, what is the correct search technique?
- A. Random search without any guideline
- B. Systematic search following a wall on one side, using a lifeline
- C. Search the centre of the compartment first
- D. Rely only on the thermal imaging camera without physical contact
22. What does 'fire load' refer to on a ship?
- A. The weight of fire-fighting equipment carried
- B. The total amount of combustible material present in a compartment
- C. The number of fire crew assigned to an emergency
- D. The pressure rating of the fire main
23. What precaution must be taken before recharging an SCBA cylinder on board?
- A. Check that the regulator is functioning
- B. Ensure the cylinder is completely empty before refilling
- C. Verify the cylinder is within its hydrostatic test date and inspect it for damage
- D. Remove the pressure gauge before connecting to the charging panel
24. What is meant by 'fire point', as distinct from 'flash point'?
- A. The temperature at which spontaneous ignition occurs
- B. The temperature at which a liquid gives off vapour fast enough to sustain continuous burning after ignition
- C. The lowest temperature at which a substance can catch fire momentarily
- D. The temperature recorded at the centre of a fire
25. Large quantities of firefighting water accumulating on an upper deck mainly endanger the ship's stability because they:
- A. Reduce the displacement of the ship
- B. Lower the centre of gravity and make the ship stiff
- C. Raise the ship's centre of gravity and create free surface, reducing the effective GM
- D. Increase the reserve buoyancy of the ship
26. The free surface effect of firefighting water trapped in a compartment depends chiefly on the:
- A. Depth of water in the compartment
- B. Height of the compartment above the keel
- C. Temperature of the water
- D. Breadth of the free surface in the compartment
27. During a prolonged accommodation fire the ship develops an increasing list. What is the most appropriate corrective action?
- A. Increase the number of hoses to cool the fire faster
- B. Report to the command team, reduce water application where possible and remove the accumulated water by drains, scuppers or portable pumps
- C. Open all watertight doors to spread the water
- D. Fill the high-side upper deck with water to counter the list
28. Which firefighting technique helps limit the amount of water accumulating inside the ship?
- A. Running hoses continuously even after the fire is out
- B. Flooding the burning compartment completely
- C. Using water fog or spray in short controlled bursts instead of continuous solid jets
- D. Using solid jets at maximum pump pressure
29. Approximately how much weight of water is added to a ship in one hour by a single fire pump delivering 25 m³/h of seawater, if none drains away?
- A. About 250 tonnes
- B. About 25.6 tonnes
- C. About 2.5 tonnes
- D. About 0.25 tonnes
30. Why must the officer in charge of firefighting be particularly careful about stability when fighting a fire with the ship alongside a berth in port?
- A. Port fire brigades only use foam
- B. The mooring lines will prevent any list
- C. Many ships have capsized alongside after large volumes of firefighting water were applied by shore fire brigades
- D. Ships alongside do not experience any free surface effect
Set 15 — 30 AFF exit exam questions with answers
1. Which item should be kept monitored and reported regularly to the command team throughout a firefighting operation using water?
- A. The barometric pressure
- B. The wind speed on the bridge wing only
- C. The fuel consumption of the main engine
- D. The ship's list, trim and draughts
2. Before using large quantities of water on a fire in a cargo hold, which information should the officer in charge obtain?
- A. The crew overtime records
- B. The stability condition and the ability to drain or pump out the hold
- C. The last port of call
- D. The voyage charter party terms
3. When the ship develops a list during firefighting and the GM is suspected to be negative (angle of loll), which action is dangerous?
- A. Removing free water from upper decks
- B. Reducing the amount of water applied
- C. Pumping ballast into high-side tanks to bring the ship upright
- D. Lowering the centre of gravity by removing high weights
4. Why should scuppers and deck drains be kept clear during firefighting operations?
- A. To allow fresh air into the accommodation
- B. To allow shore fire brigades to connect their hoses
- C. To make the deck easier to clean afterwards
- D. To allow firefighting water to drain overboard and limit free surface and added weight
5. Water spray and fog are preferred for stability reasons because, compared with a solid jet, they:
- A. Convert entirely into steam and leave no water behind
- B. Absorb more heat per unit volume, so much less water is required
- C. Weigh less per cubic metre
- D. Do not enter the ship's compartments
6. A ship fitted with a fixed water-based fire-extinguishing system in a ro-ro space must have arrangements to:
- A. Transfer the water to the double-bottom tanks only
- B. Retain all discharged water on the vehicle deck
- C. Close all scuppers automatically when the system operates
- D. Drain and pump the water discharged so as to prevent a build-up of free surface
7. Under STCW Table A-VI/3, what is the purpose of investigating an incident involving fire on board?
- A. To decide the ship's next port
- B. To calculate the insurance claim
- C. To assess the cause of the fire and prevent its recurrence
- D. To find a crew member to blame
8. When examining a fire scene, the point of origin of the fire is usually indicated by:
- A. The area furthest from the deepest charring
- B. The position of the nearest fire extinguisher
- C. The area of deepest charring and the apex of V-shaped burn patterns
- D. The location where the fire was finally extinguished
9. Immediately after a fire has been extinguished, what should be done to support the subsequent investigation?
- A. Clean the area and repaint it as quickly as possible
- B. Restart the ventilation and leave the area open to all
- C. Throw away all burnt debris overboard
- D. Preserve the scene, restrict access and photograph it before anything is moved
10. Why should witnesses of a shipboard fire be interviewed as soon as practicable?
- A. Their recollection is most accurate and least influenced by others soon after the event
- B. Interviews are only valid within one hour
- C. It replaces the need for physical evidence
- D. It allows the master to avoid making a report
11. Following a serious fire, which electronic record should be saved without delay to preserve information for the investigation?
- A. The voyage data recorder (VDR) data
- B. The weather fax archive
- C. The ship's entertainment system log
- D. The crew's personal mobile phone records
12. Under the ISM Code, a fire on board must be reported and analysed as part of which requirement?
- A. Documentation control
- B. Reports and analysis of non-conformities, accidents and hazardous occurrences
- C. Resources and personnel
- D. Company responsibilities and authority
13. A fire report compiled by the ship's officers should include:
- A. Only the weather conditions
- B. Time and location of discovery, actions taken, systems used, injuries, damage and the probable cause
- C. Only the cost of damaged equipment
- D. Only the name of the person who discovered the fire
14. When analysing the cause of a fire, the investigator seeks to identify the ignition source and the:
- A. Number of crew on board
- B. Colour of the paint on the bulkheads
- C. Brand of the extinguishers used
- D. Fuel first ignited and the circumstances that brought them together
15. Which IMO instrument sets out the international standards for the marine safety investigation of a very serious marine casualty, such as a fire causing loss of life?
- A. The Casualty Investigation Code
- B. The Fire Safety Systems Code
- C. The International Safety Management Code
- D. The International Ship and Port Facility Security Code
16. During a fire investigation, the main purpose of examining melted or failed electrical components is to determine whether:
- A. The equipment was under warranty
- B. The electrical fault caused the fire or was damaged by it
- C. The crew had read the manufacturer's manual
- D. The equipment was correctly painted
17. Which entry is required in the ship's log book following a fire on board?
- A. No entry is required if the fire was extinguished quickly
- B. Only the time the fire alarm was reset
- C. Only the names of injured persons
- D. A factual record of the fire, actions taken and its outcome
18. The main aim of a lessons-learned review after a shipboard fire is to:
- A. Replace the master
- B. Share findings and corrective actions across the fleet so similar fires are prevented
- C. Close the investigation as quickly as possible
- D. Discipline all members of the fire party
19. What is the recommended first aid for a thermal burn on a crew member's arm?
- A. Burst any blisters to release the fluid
- B. Cool the burn with cool running water for at least 20 minutes
- C. Apply butter or oil to the burn
- D. Apply ice directly to the skin for an hour
20. When giving first aid to a burns casualty, clothing that is stuck to the burnt skin should be:
- A. Removed together with the skin
- B. Pulled off quickly
- C. Soaked in fuel and removed
- D. Left in place and cut around
21. Using the 'rule of nines', what percentage of the body surface area is represented by the front of the trunk of an adult?
- A. 18%
- B. 9%
- C. 36%
- D. 27%
22. A small or scattered burn area can be estimated by using the casualty's own palm and fingers, which represents about:
- A. 1% of the body surface area
- B. 5% of the body surface area
- C. 10% of the body surface area
- D. 0.1% of the body surface area
23. After cooling, which is a suitable dressing for a burn while awaiting further medical advice?
- A. Adhesive plaster stuck on the burn
- B. Cotton wool pressed onto the burn
- C. A tight bandage soaked in antiseptic
- D. Cling film laid loosely over the burn
24. A firefighter rescued from a smoke-filled space has soot around the nose and mouth and a hoarse voice. This most likely indicates:
- A. A minor skin irritation only
- B. Possible burns to the airway from inhaling hot gases
- C. Dehydration only
- D. A fractured jaw
25. What is the most important treatment for a casualty suffering from carbon monoxide poisoning after a fire?
- A. Lay the casualty in the space until the smoke clears
- B. Give hot drinks and keep in the smoky area
- C. Give the casualty alcohol to warm up
- D. Remove to fresh air and give high-concentration oxygen
26. A crew member has collapsed in a space where CO2 has been released. What must the rescuers do before entering?
- A. Put on self-contained breathing apparatus and follow the rescue plan
- B. Wear a dust mask
- C. Hold their breath and run in quickly
- D. Enter immediately without protection to save time
27. What first aid is appropriate for a chemical burn to the skin caused by a corrosive cargo during a fire?
- A. Cover immediately with an airtight dressing without washing
- B. Neutralise the chemical with another chemical
- C. Flush the affected area with copious amounts of water for a prolonged period
- D. Wipe the area with a dry cloth only
28. Before touching a casualty who has collapsed beside burning electrical equipment, the rescuer must:
- A. Throw water over the casualty
- B. Check the casualty's pulse first
- C. Ensure the electrical supply is isolated
- D. Apply a CO2 extinguisher to the casualty
29. A casualty with extensive burns is at particular risk of:
- A. Hypothermia only from the burns
- B. Fractures
- C. Shock due to fluid loss
- D. Snow blindness
30. During a prolonged firefighting operation, firefighters showing signs of heat exhaustion should be:
- A. Sent back in after a short drink
- B. Left in the attack team until the fire is out
- C. Relieved, moved to a cool area, rested and given fluids
- D. Given additional protective clothing
Set 16 — 30 AFF exit exam questions with answers
1. Why should a casualty collection point be designated during a major shipboard fire?
- A. So injured persons can be assessed, treated and accounted for away from the danger area
- B. So the shore authorities can collect evidence
- C. So casualties can rejoin the attack team
- D. So the fire party can store its equipment
2. What is the standard outside diameter of the flange of an international shore connection as specified in the FSS Code?
- A. 150 mm
- B. 132 mm
- C. 200 mm
- D. 178 mm
3. How many bolts and nuts are to be kept with the international shore connection according to the FSS Code?
- A. Four bolts of 16 mm diameter, 50 mm long, with nuts and eight washers
- B. Two bolts of 12 mm diameter
- C. Six bolts of 20 mm diameter
- D. Eight bolts of 16 mm diameter
4. When the local fire brigade arrives at a ship on fire alongside, which ship's officer arrangement is most helpful?
- A. A designated liaison officer meets them at the gangway with the fire control plan, crew list and cargo information
- B. All officers leave the ship to meet the brigade ashore
- C. The brigade is asked to wait until the master finishes his report
- D. The brigade is left to find its own way to the fire
5. Which information is most important to give to shore-based firefighters on their arrival?
- A. Location and extent of the fire, missing persons, actions taken, fixed systems released and dangerous goods on board
- B. The crew wage scales
- C. The ship's next port of call
- D. The charterer's details
6. Why is a duplicate set of fire control plans kept in a weathertight enclosure outside the deckhouse?
- A. To replace the plans on the bridge if they are lost
- B. For inspection by customs officers
- C. To assist shore-side firefighting personnel
- D. For use by the pilot during berthing
7. When shore firefighters are fighting a fire on board, who remains responsible for advising on the ship's stability?
- A. The ship's agent
- B. The port state control officer
- C. The master and ship's officers
- D. The shore fire chief alone
8. In a port, a fire on board should be reported to shore authorities:
- A. Only if cargo is damaged
- B. Only at the end of the cargo operation
- C. As soon as possible, by raising the alarm with the terminal and port and calling the local fire brigade
- D. Only after the crew has failed to extinguish it
9. Before shore firefighters begin applying water through the international shore connection, the ship's crew should:
- A. Ensure the correct isolating valves are set so that water reaches the required part of the fire main
- B. Disconnect all ship's hoses
- C. Stop all communication with the shore
- D. Close all valves on the fire main
10. Where can the crew find the recommended firefighting action for a specific dangerous goods cargo listed in the IMDG Code?
- A. In the GMDSS radio log
- B. In the ship's oil record book
- C. In the cargo ship safety construction certificate
- D. In the EmS Guide fire schedule referred to for that substance
11. In an EmS code such as F-E, S-D, the letter F refers to:
- A. The fire schedule
- B. The flash point
- C. The freeboard
- D. The first aid procedure
12. Why should water not be used on a fire involving IMDG Class 4.3 substances?
- A. They are radioactive
- B. They emit flammable gases when in contact with water
- C. Water reacts to form CO2
- D. They are always explosive
13. Smothering methods are of limited use against fires involving IMDG Class 5.1 oxidizing substances because:
- A. The substance releases oxygen which supports combustion
- B. They cannot burn
- C. They are always water-reactive
- D. They extinguish themselves
14. Which document on board identifies the dangerous goods carried and their stowage location, and is needed by firefighters?
- A. The dangerous goods manifest or detailed stowage plan
- B. The garbage record book
- C. The crew list
- D. The deck log abstract
15. A fire threatens a container stowage position close to IMDG Class 1 explosives. What is the main priority?
- A. Ignoring the explosives as they are packed
- B. Applying a small CO2 extinguisher to the explosives
- C. Opening the containers to inspect the explosives
- D. Intensive cooling of the containers and boundaries to keep the explosives cool, and preparing to evacuate if it cannot be controlled
16. Which guide is used to give medical first aid for casualties exposed to dangerous goods?
- A. The EmS spillage schedule only
- B. The IAMSAR Manual Volume II
- C. The Code of Safe Working Practices only
- D. The Medical First Aid Guide (MFAG)
17. Lithium-ion batteries involved in a fire are dangerous mainly because:
- A. They do not produce toxic gases
- B. They can go into thermal runaway and reignite after apparent extinguishment
- C. They cannot burn without external oxygen
- D. They are extinguished permanently by a small CO2 discharge
18. When fighting a fire near leaking dangerous goods on deck, firefighters should approach from:
- A. Directly above, from the bridge wing
- B. Any direction, as the direction does not matter
- C. Downwind, to cool the vapour cloud
- D. Upwind, keeping clear of vapours and run-off
19. Fire involving ammonium nitrate based fertilizer in a hold should normally be fought with:
- A. Steam smothering
- B. The fixed CO2 system alone
- C. Dry sand
- D. Copious quantities of water
20. What is meant by 'dry distillation' in firefighting?
- A. Drying wet cargo before stowage
- B. Removing water from foam concentrate
- C. Distilling seawater for fire mains
- D. Decomposition of combustible material by heat without flame contact, releasing flammable gases
21. How can fire spread by dry distillation to an adjacent cabin best be prevented?
- A. By switching on the cabin ventilation
- B. By opening the adjacent cabin door
- C. By closing the scuppers
- D. By boundary cooling the bulkheads and removing combustibles from the adjacent space
22. What is a 'flashover'?
- A. Sudden involvement of all combustible surfaces in a compartment when radiant heat raises them to their ignition temperature
- B. An explosion caused by opening a door into a smoke-filled space
- C. The ignition of a liquid at its flash point only
- D. A small spark from an electrical switch
23. Which signs warn of a possible backdraft before opening a door to a fire compartment?
- A. Smoke puffing in and out of gaps, little visible flame and very hot door surfaces
- B. Clear air and no smoke
- C. Bright open flames visible through the door
- D. Low temperature of the door and white steam
24. Fires in exhaust gas boilers and economisers (uptake fires) are usually caused by:
- A. Lightning strikes on the funnel
- B. Seawater leaking into the boiler
- C. Ignition of accumulated soot and unburnt oil deposits
- D. Overloading of the electrical generator
25. Why is a small quantity of water dangerous on a very high-temperature exhaust gas boiler fire?
- A. Water may dissociate into hydrogen and oxygen, causing a hydrogen fire or explosion
- B. Water makes the soot non-flammable permanently
- C. Water instantly freezes on the tubes
- D. Water reacts with the steel to form CO2
26. Why is water fog in a small, closed compartment hazardous to firefighters?
- A. Fog conducts electricity at all voltages
- B. Conversion of water to steam causes a large volume expansion that can scald firefighters
- C. Fog cannot absorb any heat
- D. Fog increases the oxygen content of the space
27. What dangerous gas is produced when water is applied to burning magnesium?
- A. Carbon dioxide
- B. Argon
- C. Hydrogen
- D. Nitrogen
28. When the oxygen content in a closed compartment fire falls, the fire produces more:
- A. Pure carbon dioxide only
- B. Carbon monoxide and unburnt flammable gases
- C. Water vapour only
- D. Nitrogen
29. Which condition increases the likelihood of a fire in the scavenge air space of a two-stroke diesel engine?
- A. Using fresh water cooling
- B. Running the engine at constant full load with clean scavenge spaces
- C. Low ambient air temperature only
- D. Accumulation of cylinder oil and carbon deposits with blow-by of hot gases past the piston rings
30. Under SOLAS II-2/10.10.4, how many two-way portable radiotelephone apparatus must be carried for each fire party?
- A. Four
- B. A minimum of two
- C. Three
- D. One
Set 17 — 37 AFF exit exam questions with answers
1. Portable radios used by fire parties must be of which type?
- A. Any domestic VHF type
- B. Explosion-proof or intrinsically safe
- C. Satellite phones
- D. Mobile phones
2. What is the purpose of a BA entry control board used during firefighting?
- A. To record who has entered, their time of entry and cylinder pressure, and when they are due out
- B. To list the cargo carried
- C. To record the ventilation fan numbers
- D. To show the fire control plan symbols
3. Which report from the on-scene leader to the command team is most useful?
- A. Only a request for more coffee
- B. A short, clear report of the fire's location, extent, actions taken and resources needed
- C. Silence until the fire is out
- D. A detailed description of each crew member's personal feelings
4. Why should a closed-loop confirmation be used when giving orders such as 'stop ventilation fans' during a fire?
- A. It prevents anyone else using the radio
- B. The receiver repeats the order and reports back when completed, confirming it was understood and done
- C. It reduces the number of reports needed
- D. It is required only for cargo operations
5. If radio communication between the BA team and the entry control point fails, the team should:
- A. Remove their face masks to shout
- B. Split up to search for a better signal
- C. Withdraw from the space following the agreed procedure
- D. Continue indefinitely until radio returns
6. Under SOLAS III/19, how often must each crew member of a cargo ship take part in a fire drill?
- A. Once a year
- B. Only when joining the ship
- C. At least once every month
- D. Once every three months
7. According to SOLAS III/19, onboard training in the use of the ship's fire-extinguishing appliances must be given to new crew members:
- A. Within six months of joining
- B. As soon as possible but not later than two weeks after they join the ship
- C. Before their first shore leave
- D. Only during the annual survey
8. A SOLAS fire drill should include starting a fire pump and using at least how many jets of water to show the system is in proper working order?
- A. Six
- B. Four
- C. One
- D. Two
9. Under the ISM Code, shipboard contingency plans for fire are required by the element dealing with:
- A. Company verification, review and evaluation
- B. Maintenance of the ship and equipment
- C. Emergency preparedness
- D. Master's responsibility and authority
10. In a typical shipboard emergency organisation, the overall command of a fire is exercised by the master from:
- A. The bridge or designated command centre
- B. The scene of the fire inside the compartment
- C. The engine control room only
- D. The lifeboat embarkation deck
11. When allocating personnel to fire parties, which is a key principle?
- A. The youngest crew member always leads
- B. Officers are never included in fire parties
- C. Each team has a leader and members trained and physically fit for their assigned duties, including BA wearers
- D. All crew are put in one large team
12. Where must the fire safety training manual be provided on board?
- A. Only in the engine control room
- B. Only in the master's office
- C. Only in the ship's office ashore
- D. In each crew mess room and recreation room, or in each crew cabin
13. Which SOLAS document contains the ship-specific information on fire safety operation, such as cargo handling precautions and fire safety maintenance?
- A. The garbage management plan
- B. The fire safety operational booklet
- C. The ship security plan
- D. The cargo securing manual
14. Which IMO resolution sets out the graphical symbols for shipboard fire control plans?
- A. Resolution A.1116(30)
- B. Resolution A.952(23)
- C. Resolution MSC.48(66)
- D. Resolution A.741(18)
15. Which of the following must be shown on the fire control plan?
- A. Particulars of the ventilation system, including fan control positions, dampers and identification numbers of the fans serving each section
- B. The crew's working hours
- C. The ship's charter party
- D. The location of each crew member's cabin number only
16. When alterations are made to the ship's fire protection arrangements, the fire control plan must be:
- A. Changed only at the next dry-docking
- B. Updated only by the flag State
- C. Left unchanged until the ship is sold
- D. Kept up to date, with the alterations recorded as soon as practicable
17. SOLAS Chapter II-2 is divided into Parts. Which Part deals with suppression of fire, including detection, containment and fighting of fire?
- A. Part A
- B. Part C
- C. Part F
- D. Part G
18. Which SOLAS regulation requires a maintenance plan for the ship's fire protection systems and appliances?
- A. SOLAS III/20
- B. SOLAS II-2/4
- C. SOLAS II-2/14
- D. SOLAS V/19
19. According to IMO guidelines for portable fire extinguishers (Res. A.951(23)), how often should extinguishers be inspected by a competent person?
- A. Only after use
- B. Every five years only
- C. Annually
- D. Every ten years only
20. Under IMO guidelines, at least one portable extinguisher of each type manufactured in the same year should be test discharged at intervals of:
- A. Two years
- B. Five years
- C. One year
- D. Fifteen years
21. Portable fire extinguishers and propellant cartridges should be hydrostatically tested at intervals not exceeding:
- A. Thirty years
- B. Twenty years
- C. Ten years
- D. Two years
22. For a cargo ship, which statutory certificate covers the fire-extinguishing appliances and fire control plans?
- A. International Load Line Certificate
- B. Cargo Ship Safety Radio Certificate
- C. International Tonnage Certificate
- D. Cargo Ship Safety Equipment Certificate
23. Under MSC.1/Circ.1432, which check of the fire detection and alarm system is carried out weekly?
- A. Verify that all fire detection and fire alarm control panel indicators are functional by operating the lamp or indicator test switch
- B. Blow-through test of all CO2 pipes
- C. Replacement of all detector heads
- D. Hydrostatic test of the fire main
24. According to the FSS Code, heat detectors must operate before the temperature exceeds 78°C but not at temperatures below:
- A. 40°C
- B. 93°C
- C. 54°C
- D. 68°C
25. According to the FSS Code, what is the maximum floor area per smoke detector in a fixed fire detection system?
- A. 37 m²
- B. 100 m²
- C. 150 m²
- D. 74 m²
26. If a fire detection alarm has not received attention within a specified time, the FSS Code requires an audible alarm to be automatically sounded throughout crew accommodation, service spaces, control stations and machinery spaces. This time is:
- A. 5 minutes
- B. 2 minutes
- C. 10 minutes
- D. 30 seconds
27. How many sources of power are required for the electrical equipment of a fixed fire detection and fire alarm system?
- A. A dedicated battery only
- B. Three main generators
- C. Not less than two, one of which shall be the emergency source
- D. One main source only
28. What does an 'A-60' class division mean?
- A. A combustible division lasting 60 seconds
- B. A steel division which also limits the average temperature rise on the unexposed side to 140°C for 60 minutes in the standard fire test
- C. A division tested at 60°C
- D. A division that prevents only the passage of flame for 60 minutes
29. 'C' class divisions are those which:
- A. Are constructed of approved non-combustible materials with no requirement for smoke or flame passage or temperature rise
- B. Are made of combustible wood
- C. Prevent the passage of smoke and flame for one hour
- D. Are insulated to A-60 standard
30. In passenger ships, the mean length of a main vertical zone on any deck should not normally exceed:
- A. 60 m
- B. 100 m
- C. 40 m
- D. 24 m
31. Fire doors in main vertical zone bulkheads and stairway enclosures must be capable of closing against an inclination of:
- A. 3.5° opposing closure
- B. 10° opposing closure
- C. 1° opposing closure
- D. 25° opposing closure
32. From 1 January 2026, SOLAS II-2/10 as amended prohibits the use of fire-fighting foams containing which substance?
- A. Fluoroprotein without PFOS
- B. Perfluorooctane sulfonic acid (PFOS)
- C. Detergent surfactants
- D. Protein hydrolysate
33. Why has IMO prohibited fire-fighting foams containing PFOS?
- A. PFOS foams freeze at room temperature
- B. PFOS foams are too expensive
- C. PFOS foams do not extinguish oil fires
- D. PFOS is persistent, bioaccumulative and toxic to the environment and human health
34. For an existing ship carrying foam concentrate containing PFOS, the SOLAS amendment requires the foam to be replaced:
- A. Only at the ship's next special survey after 2030
- B. Only when the foam has expired
- C. It may be kept indefinitely on existing ships
- D. Not later than the first survey on or after 1 January 2026
35. In a low-pressure CO2 system, the liquid CO2 is stored in a refrigerated tank at a pressure of about:
- A. 1 bar at 0°C
- B. 2 N/mm² (20 bar) at around -18°C
- C. 60 bar at 40°C
- D. 200 bar at ambient temperature
36. Why must ventilation to a fire compartment be stopped and dampers closed early in the firefighting operation?
- A. To dry the space for later inspection
- B. To increase visibility for firefighters inside
- C. To cool the space
- D. To limit the oxygen supply and prevent smoke and fire spreading through the ducting
37. When is controlled ventilation of a fire compartment appropriate during the attack?
- A. As soon as the fire is discovered, before any team is ready
- B. Only after leaving the space unattended overnight
- C. Never, under any circumstances
- D. When coordinated with the attack team to remove heat and smoke, with charged hoses in position
Printing this? Use your browser's Print (Ctrl/⌘ + P) — the buttons, the search box and the site chrome drop out and the questions run on as plain text, so a set fits a few pages. Filter to one set first if you only want that set on paper.