HV exit exam questions and answers — Set 2 — High Voltage Safety Officer & Switchgear Operations
Set 2 of the High Voltage Safety Officer & Switchgear Operations (HV) exit exam bank — 30 of 428 questions, with the correct option marked and a one-line explanation for every one. Read it end to end, jump to a single set, or search it — then sit the same bank as a timed paper. The real DG Shipping exit exam is 30 marks with 15 to pass.
These are the bank's original groupings. Practising deals the whole bank out again every time you reshuffle, so a practice “Set 3” is a different 30 questions each time — the set numbers below are the source file's, and are only used here so the key stays navigable. Options are listed in their original order with fixed letters; when you practise, those move too.
Bank last rebuilt .
30 of 30 shown · Set 2
Nothing in this set matches that. Try a shorter word, or search the whole key.
Set 2 — 30 HV exit exam questions with answers
1. What safety enclosure rating (IP Rating) is required for High Voltage marine switchboard cubicles?
- A. IP00
- B. IP10
- C. No rating
- D. IP2X minimum (protection against touch) up to IP44/IP54 for splash protection
2. What is the function of a High Voltage bus tie breaker?
- A. Ties ropes
- B. Connects or isolates two separate HV busbar sections for operational flexibility and redundancy
- C. Connects battery charger
- D. Regulates water
3. What device measures temperature continuously inside HV motor or generator stator windings?
- A. Pressure gauge
- B. Glass thermometer
- C. Resistance Temperature Detectors (RTD - PT100) or Thermocouples
- D. Hydrometer
4. What procedure is followed during Sanction to Test on High Voltage equipment?
- A. Temporarily remove safety earths under strict control to perform insulation or hi-pot testing, then re-earth
- B. Remove warning signs
- C. Turn on generator full load
- D. Cancel permit
5. What is High Potential (Hi-Pot) dielectric testing on HV cables?
- A. Testing battery with bulb
- B. Applying elevated DC/AC voltage (e.g. 2x rated voltage) to verify cable dielectric withstand strength
- C. Measuring length
- D. Checking cable color
6. What is the function of a surge arrestor connected to HV generator terminals?
- A. Cool generator
- B. Reduce noise
- C. Divert high-voltage switching surges and lightning spikes safely to ground
- D. Increase generator power
7. What risk occurs if an HV circuit breaker is closed into a solid phase-to-phase short circuit fault?
- A. Massive fault current flows; instantaneous overcurrent relays must trip breaker within cycles
- B. Heats up slowly over hours
- C. Voltage increases smoothly
- D. Speed increases
8. What safety floor matting must be placed in front of marine High Voltage switchboards?
- A. Aluminum plate
- B. Steel mesh mat
- C. Wet cloth rag
- D. Tested dielectric insulating rubber matting (rated for operating voltage, e.g. 15 kV - 30 kV rating)
9. What type of fire extinguisher is mandatory near High Voltage switchboard rooms?
- A. Foam pipe
- B. Water jet
- C. Carbon Dioxide (CO2) or Clean Agent non-conducting gas extinguishers
- D. Saltwater hose
10. Who keeps primary key to safety padlocks securing an HV isolation point under a Permit to Work?
- A. Messman
- B. Anyone on deck
- C. Pilot
- D. The High Voltage Authorised Person (HVAP) / Person in Charge of work
11. What is the function of a zero-sequence current transformer (ZSCT) in core-balance earth fault protection?
- A. Control temp
- B. Measure RPM
- C. Detect vector sum of 3-phase currents; any non-zero value indicates earth leakage current
- D. Measure battery
12. What is the effect of harmonics generated by large High Voltage variable frequency drives (VFD)?
- A. Cleans contacts
- B. Reduces cable size
- C. Increases efficiency 50%
- D. Voltage waveform distortion, overheating of transformers/generators, and electronic interference
13. What maintenance step is required before cleaning HV switchboard busbar compartments?
- A. Complete isolation, prove dead, apply portable earths, post warning signs, and issue HV PTW
- B. Spray solvent live
- C. Blow compressed air live
- D. Wipe live with damp cloth
14. What is the function of an Automatic Voltage Regulator (AVR) on an HV generator?
- A. Control generator field excitation to maintain steady terminal voltage under changing load
- B. Measure oil pressure
- C. Cool bearings
- D. Control engine RPM
15. What is the purpose of an anti-condensation heater fitted inside HV electric motors and switchboards?
- A. Heat engine room
- B. Warm lube oil
- C. Dry clothes
- D. Maintain internal temperature slightly above ambient when stopped to prevent moisture condensation
16. What safety precaution must be observed when using a high voltage test probe to prove equipment dead?
- A. Use low voltage light
- B. Test probe on known live source FIRST, test target equipment, then re-test probe on known live source ('Live-Dead-Live' test)
- C. Test on table
- D. Assume indicator works
17. What device trips an HV transformer if gas accumulation or oil surge occurs due to internal fault?
- A. Speed governor
- B. Thermocouple
- C. Buchholz Relay
- D. Reverse power relay
18. What is the purpose of Lockout / Tagout (LOTO) padlocks on HV isolators?
- A. Prevent theft
- B. Hold door open
- C. Decorate panel
- D. Physically lock isolator handles in OPEN/OFF position with warning tags so no one can re-energize circuit
19. What action must be taken immediately if a colleague contacts a High Voltage live conductor and collapses?
- A. Throw water
- B. Grab victim's arm bare hands
- C. Run away
- D. DO NOT touch victim directly; isolate HV power source immediately or use certified HV insulating rescue hook to pull victim away, then call emergency CPR
20. Who has overall responsibility for enforcing High Voltage safety management systems on board?
- A. Ship cook
- B. Port Agent
- C. Shore electrician
- D. The Chief Engineer and Ship's Master
21. Which document contains the shipyard's description of operations regarding the vessel's High Voltage (HV) equipment?
- A. Preliminary operation manual
- B. High voltage operation manual
- C. Performance manual
- D. Equipment manual
22. A low voltage protection circuit is used in electric motor starting equipment to:
- A. Trip circuit contactor when the motor over-speeds due to low voltage
- B. Trip circuit contactor when the motor develops short circuit due to low voltage
- C. Allow the motor to restart automatically on restoration of voltage without manual resetting
- D. Prevent motor from restarting automatically upon restoration of supply voltage
23. In air blast circuit breakers, the compressed air pressure used for arc quenching is in the order of:
- A. 100 mm Hg
- B. 1 kg/cm²
- C. 20 to 30 kg/cm²
- D. 200 to 300 kg/cm²
24. What is the primary means by which an electrical maintenance worker is protected from electrical hazards while performing work on an electrical circuit?
- A. Shutting down the necessary equipment only
- B. Using personal protective equipment (PPE) alone
- C. Posting safety warning signs
- D. Performing a lockout / tagout (LOTO) and grounding procedure
25. What is the Polarisation Index (PI) in insulation resistance testing?
- A. Ratio of 10-minute insulation resistance to 1-minute insulation resistance
- B. Ratio of 1-minute insulation resistance to 10-minute insulation resistance
- C. Ratio of 5-minute insulation resistance to 25-minute insulation resistance
- D. Ratio of test voltage to leakage current after 1 minute
26. The direction of mechanical force experienced by a current-carrying conductor placed in a magnetic field is determined by:
- A. Fleming's left-hand rule
- B. Fleming's right-hand rule
- C. Helix rule
- D. Corkscrew rule
27. Which of the following insulating media can be used in sphere gaps and high-voltage test setups?
- A. Liquid insulation (e.g., transformer oil)
- B. Solid insulation (e.g., polyester, resin-bonded paper)
- C. Gas insulation (e.g., SF6, N2, CO2, CCl2F2)
- D. Any of the above
28. Cartridge and rewireable fuse protection in general distribution circuits is typically used for continuous current ratings up to:
- A. 10 A
- B. 20 A
- C. 50 A
- D. 100 A
29. Which of the following circuit breakers provides high operating reliability and minimal maintenance requirements?
- A. Air blast circuit breaker
- B. SF6 gas circuit breaker
- C. Vacuum circuit breaker
- D. Bulk oil circuit breaker
30. Which type of work procedure involves electrical installations that are completely de-energized, isolated, proven dead, and earthed?
- A. Live working
- B. Dead working
- C. Working in the vicinity of live parts
- D. Hot line working
Printing this? Use your browser's Print (Ctrl/⌘ + P) — the buttons, the search box and the site chrome drop out and the questions run on as plain text, so a set fits a few pages. Filter to one set first if you only want that set on paper.