FPFF exit exam questions and answers — Set 21 — Fire Prevention & Fire Fighting
Set 21 of the Fire Prevention & Fire Fighting (FPFF) exit exam bank — 30 of 656 questions, with the correct option marked and a one-line explanation for every one. Read it end to end, jump to a single set, or search it — then sit the same bank as a timed paper. The real DG Shipping exit exam is 30 marks with 15 to pass.
These are the bank's original groupings. Practising deals the whole bank out again every time you reshuffle, so a practice “Set 3” is a different 30 questions each time — the set numbers below are the source file's, and are only used here so the key stays navigable. Options are listed in their original order with fixed letters; when you practise, those move too.
Bank last rebuilt .
30 of 30 shown · Set 21
Nothing in this set matches that. Try a shorter word, or search the whole key.
Set 21 — 30 FPFF exit exam questions with answers
1. When several casualties are brought out from a fire scene, how should the first-aid team decide whom to treat first?
- A. By treating casualties in the order they were brought out
- B. By rank, treating senior officers first
- C. By treating the casualty who is shouting loudest first
- D. By triage, giving priority to life-threatening airway, breathing and circulation problems
2. Under FSS Code chapter 9, smoke detectors must be certified to operate before smoke density exceeds what obscuration per metre?
- A. 50%
- B. 25%
- C. 2%
- D. 12.5%
3. Under FSS Code chapter 9, heat detectors in normal spaces must operate before the temperature exceeds what value (rate of rise less than 1°C per minute)?
- A. 78°C
- B. 54°C
- C. 130°C
- D. 100°C
4. What is the maximum floor area per smoke detector given in FSS Code chapter 9?
- A. 37 m²
- B. 100 m²
- C. 150 m²
- D. 74 m²
5. Heat detectors respond more slowly than smoke detectors. Under FSS Code chapter 9, what is the largest floor area that one heat detector may cover?
- A. 20 m²
- B. 37 m²
- C. 50 m²
- D. 74 m²
6. Which type of fire detector responds to ultraviolet or infrared radiation emitted by flames?
- A. Ionisation smoke detector
- B. Rate-of-rise heat detector
- C. Flame detector
- D. Fixed-temperature heat detector
7. Under FSS Code chapter 9, a section of fire detectors covering a control station, service space or accommodation space shall NOT include which space?
- A. A machinery space of category A
- B. A stairway enclosure
- C. A corridor of the same deck
- D. A cabin on the same deck
8. How are fixed fire detection systems required to be tested regularly on board?
- A. Only by pressing the test button on the control panel
- B. Only by the manufacturer at five-yearly intervals
- C. By holding a lit match under each detector
- D. Using equipment producing hot air, smoke or aerosol particles at the detector
9. Where must the control panel of a fixed fire detection and fire alarm system be located?
- A. In the CO2 room
- B. On the navigation bridge or in the continuously manned central control station
- C. In the steering gear room
- D. In the engine-room workshop
10. For a CO2 system protecting a machinery space, the quantity of CO2 must be sufficient to give a minimum volume of free gas equal to what percentage of the gross volume of the largest machinery space, excluding the casing?
- A. 25%
- B. 30%
- C. 85%
- D. 40%
11. For calculating the quantity of CO2 required, the volume of free carbon dioxide is taken as how many cubic metres per kilogram?
- A. 0.25 m³/kg
- B. 0.56 m³/kg
- C. 1.56 m³/kg
- D. 1.0 m³/kg
12. How many separate controls are required for releasing CO2 into a protected space, and in what order must they operate?
- A. Two: one opens the valve to the space, the other discharges the gas from the containers
- B. Three: alarm, ventilation stop and release, in any order
- C. Two, which may be operated in any order
- D. One single push-button that releases all cylinders
13. For a CO2 system protecting a space normally entered by personnel, how long must the pre-discharge alarm operate before the gas is released?
- A. Exactly 2 minutes
- B. At least 20 seconds
- C. At least 5 seconds
- D. No delay is required
14. SOLAS requires fixed local application fire-fighting systems (such as water mist) in machinery spaces of category A above 500 m³ in ships of what size?
- A. 500 gross tonnage and above
- B. 10,000 gross tonnage and above
- C. 2,000 gross tonnage and above
- D. All passenger ships only
15. Which arrangement is required for a galley exhaust duct passing through accommodation spaces?
- A. Only a mesh screen at the hood
- B. A CO2 portable extinguisher inside the duct
- C. No special arrangement if the duct is steel
- D. A grease trap, a fire damper and a fixed means of extinguishing a fire in the duct
16. In a fixed high-expansion foam system for machinery spaces, what is the maximum expansion ratio permitted by the FSS Code for the traditional system?
- A. 10,000 to 1
- B. 100 to 1
- C. 1,000 to 1
- D. 12 to 1
17. Under current SOLAS II-2/4.5.5, oil tankers constructed on or after 1 January 2016 must be fitted with a fixed inert gas system if they are of at least what deadweight?
- A. 40,000 tonnes
- B. 8,000 tonnes
- C. 5,000 tonnes
- D. 20,000 tonnes
18. Under the FSS Code, the inert gas system must be capable of delivering inert gas with an oxygen content not exceeding what percentage by volume?
- A. 8%
- B. 21%
- C. 11%
- D. 5%
19. In an inerted cargo tank, the oxygen content of the tank atmosphere must be maintained at not more than what percentage by volume?
- A. 15%
- B. 8%
- C. 11%
- D. 5%
20. Approximately what is the flammable range of typical crude oil hydrocarbon gas mixed with air?
- A. About 15% to 50% by volume
- B. About 0.1% to 1% by volume
- C. About 10% to 30% by volume
- D. About 1% to 10% by volume
21. Under SOLAS II-2/4.5.10, the hydrocarbon gas detection system in a cargo pump-room must alarm at a pre-set level not higher than what?
- A. 100% of the lower flammable limit
- B. 1% of the upper flammable limit
- C. 50% of the lower flammable limit
- D. 10% of the lower flammable limit
22. What minimum ventilation capacity does SOLAS require for the mechanical exhaust ventilation of a tanker's cargo pump-room?
- A. 6 air changes per hour
- B. 45 air changes per hour
- C. 20 air changes per hour
- D. 10 air changes per hour
23. Which fixed fire-extinguishing systems are acceptable under SOLAS II-2/10.9 for the cargo pump-room of an oil tanker?
- A. Only portable dry powder extinguishers
- B. Steam smothering only
- C. Only the deck foam monitors
- D. CO2, high-expansion foam or fixed pressure water-spraying
24. According to ISGOTT, before hot work in a cargo tank, the hydrocarbon gas concentration in the tank should not exceed what value?
- A. 1% of the LFL
- B. 5% by volume
- C. 10% of the LFL
- D. 50% of the LFL
25. A fire breaks out at the cargo manifold of a tanker discharging at a terminal. What should be done first?
- A. Raise the alarm, stop cargo operations and close manifold valves, and inform the terminal
- B. Open all tank lids to release pressure
- C. Disconnect the hoses immediately while cargo is flowing
- D. Continue discharging to empty the tanks quickly
26. What is the purpose of emergency towing-off pennants (fire wires) rigged on a tanker alongside an oil terminal?
- A. To allow tugs to tow the ship off the berth in an emergency such as fire
- B. To secure the cargo hoses to the manifold
- C. To earth the ship to the shore and prevent static
- D. To hang fenders against the jetty
27. In the tanker emergency organisation recommended by ISGOTT, which group directs the response and maintains external communications?
- A. The command team, normally led by the Master on the bridge or cargo control room
- B. The back-up team at the accommodation
- C. The terminal's mooring gang
- D. The engineers' group in the engine room
28. A fire occurs at the outlet of a cargo tank vent (mast riser) during loading. What is the first action?
- A. Open the tank ullage ports to divert the vapour
- B. Increase the loading rate to clear the vent
- C. Stop loading so that vapour flow from the vent ceases
- D. Shut down the inert gas system immediately
29. Under FSS Code chapter 14, what is the maximum expansion ratio of the foam produced by a tanker's fixed deck foam system?
- A. 100 to 1
- B. 500 to 1
- C. 12 to 1
- D. 1,000 to 1
30. Under FSS Code chapter 14, the foam solution supply rate must be not less than the greatest of several values. Which is one of them?
- A. 1 l/min per m² of accommodation deck area
- B. 0.1 l/min per m² of cargo deck area
- C. 0.6 l/min per m² of cargo deck area
- D. 10 l/min per m² of cargo deck area